Step 4: Make Id Sets For Twisted Pair And Fiber Cabling; To See The Cable Id Setup Screen; To Make A Cable Id Set For Tests On; Twisted Pair Cabling - Fluke Versiv Series Technical Reference Handbook

Hide thumbs Also See for Versiv Series:
Table of Contents

Advertisement

Versiv Series Cabling Certification Product Family
Technical Reference Handbook

Step 4: Make ID Sets for Twisted Pair and Fiber Cabling

To see the CABLE ID SETUP screen

On the home screen, tap the PROJECT panel, then tap NEW ID
SET on the PROJECT screen.
Or, on the home screen, tap the Next ID panel, tap CHANGE
CABLE IDs, then tap NEW ID SET on the CHANGE CABLE IDs
screen (see Figure 197 on page 525).
When you make cable ID sets, you set up these items for the
project (see Figure 198 on page 526):
Sets of IDs to use when you save test results. For example, you
can make one set of IDs for multimode fibers and another for
twisted pair copper cables.
For projects that use an OptiFiber Pro or CertiFiber Pro
module, you specify the tests to do for each ID. As you use the
project, the tester shows the percentage of the necessary tests
you have completed. It also shows the IDs that do not have
results for each test.
For this tutorial, your project will include ID sets for 12 twisted
pair cables and 10 fiber optic cables (5 duplex fiber links). It is not
necessary to attach a copper or fiber module before you set up an
ID set for that module.
To make a cable ID set for tests on twisted pair cabling
On the home screen, tap the PROJECT panel, then tap NEW
4-1
ID SET on the PROJECT screen.
4-2. For this tutorial, you will make an ID set that has 12 IDs for

twisted pair cabling:

a. On the CABLE ID SETUP screen (Figure 198 on page 526),
tap the box under First ID, use the keyboard to enter B-00.
522

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

VersivVersiv 2Dsx-8000Dsx-5000Cfp2-100-q-int

Table of Contents