OptiFiber Pro OTDR Module Specifications

OTDR Port
Wavelengths
Compatible Fiber Types
Event Dead Zone
Attenuation Dead Zone
1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse
width. Reflection peak < -40 dB for multimode and < -50 dB for singlemode.
2. Measured at  0.5 dB deviation from backscatter, with a reflection peak < -40 dB and
a 3 ns pulse width for multimode, and < -50 dB and a 10 ns pulse width for
singlemode.
622
Multimode
SC standard
Cleanable and
interchangeable
UPC polish
850 nm 10 nm
1300 nm +35 / -15 nm
50/125 μm
62.5/125 μm
multimode fiber
1
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
2
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
Singlemode
SC standard
Cleanable and
interchangeable
UPC polish
1310 nm 25 nm
1550 nm 30 nm
Singlemode fiber
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical