Make Sure Your Tester is Ready to Certify Twisted Pair Cabling

Make Sure Your Tester is Ready to Certify
Twisted Pair Cabling
To make sure your tester meets its accuracy specifications, follow
these guidelines:
Keep the tester's software current. The latest software is
available on the Fluke Networks website. See "Update the
Software" on page 589.
At a minimum, set the reference for the twisted pair adapters
every 30 days. Because this procedure includes a self test and
helps ensure maximum accuracy of test results, the best
practice is to set the reference each day. See "Set the
Reference" on page 82.
Make sure you select the correct cable type for the job, and
that the NVP for the cable is correct. See Table 3 on page 84.
Make sure you select the correct test limit for the job. See
Table 3 on page 84.
Make sure the cords and connectors for all test equipment
and patch cords are in good condition.
Make sure the battery is fully charged.
Send the modules to a Fluke Networks service center every 12
months for factory calibration.
Chapter 3: Certify Twisted Pair Cabling