Fluke Versiv Series Technical Reference Handbook page 278

Hide thumbs Also See for Versiv Series:
Table of Contents

Advertisement

Versiv Series Cabling Certification Product Family
Technical Reference Handbook
Shows a summary of the test results in the project:
The number of tests that passed.
The number of tests that failed.
The test setup panel shows the settings the tester will use when
you tap TEST or press .
To change these settings, tap the panel, select the test on the
CHANGE TEST screen, tap EDIT, select different settings on the
TEST SETUP screen, then tap SAVE. See Table 11 on page 253.
You can set up tests for any module that the
tester can use, even when no module is attached.
Next ID: The Next ID panel shows the ID that the tester gives to
the next test results you save. For Smart Remote mode, this
panel shows IDs for main tester's input and output fibers.
Tap Next ID to do these tasks:
Enter an ID, select a different ID in the ID set, select a
different set of IDs, or make a new set. The tester adds the
IDs and ID sets you make to the project that shows on the
home screen.
Turn Auto Save on or off.
Operator: The name of the person who does the job. You can
enter a maximum of 20 operator names. For each operator you
can also enter the email address that the operator will use as an
ID to sign in to LinkWare Live.
TOOLS: The TOOLS menu lets you set the reference for fiber
tests, see the status of the tester, and set user preferences such as
the language and the display brightness.
SET REF: Tap SET REF to set the reference and verify your test
reference cords for loss/length tests.
242
Note

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: