Versiv Series Cabling Certification Product Family
Technical Reference Handbook
If Bi-directional is On: Halfway through the test, the tester
3-5
tells you to switch the input and output fibers. See "Bi-
directional Tests" on page 290.
Save the result:
3-6
If Auto Save is on, the tester uses the next two IDs to save
the results for the two fibers.
If Auto Save is off, tap SAVE if the test passed or FIX
LATER if the test failed. The SAVE RESULT screen shows
the next two IDs available. You can change the IDs if
necessary.
Autotest Results for Smart Remote Mode
Unsaved results show the results for both fibers. See Figures 112
and 113.
The overall result for the Autotest.
The fiber IDs and the loss and length measurements for the
fibers:
The result exceeds the limit.
The result is within the limit.
The selected test limit does not have a limit for the test.
To see the results, limits, and margins for a fiber, tap the
window. See Figure 113.
The settings the tester used for the test.
The dashed lines are around the connectors and fiber that are
included in the loss and length results. Gray connectors and
fibers are not included because you used them to set the
reference.
266