Sign In
Upload
Manuals
Brands
Fluke Manuals
Test Equipment
BT5300 Series
Fluke BT5300 Series Manuals
Manuals and User Guides for Fluke BT5300 Series. We have
1
Fluke BT5300 Series manual available for free PDF download: User Manual
Fluke BT5300 Series User Manual (168 pages)
Battery Tester
Brand:
Fluke
| Category:
Test Equipment
| Size: 6.97 MB
Table of Contents
Table of Contents
5
Title Page
9
Introduction
13
Product Overview
13
How to Contact Fluke
14
Safety Information
14
Warning and Caution
14
Symbols
16
Model Comparison Table
16
Operation Features
17
Front Panel
17
Display Screen
20
Rear Panel
23
Preparation
25
Conventions
25
Standard Packaging
25
Set the Handle Position
27
Connect to Power and Ground
29
Power on and Standby
30
Setting the Line Frequency
30
Warm-Up the Product
30
Inspection before Testing
31
Measuring with Test Leads
32
Connect the Power Cord
33
Restore to Factory Defaults
33
Connect the Test Leads
33
Select Measurement Range
34
Set Sampling Rate
34
Zero-Adjustment
35
Connect to the Cell
35
Read the Measured Voltage and Resistance
35
Measuring through Multiplexer Cards
36
Install Multiplexer Cards
37
Connect the Product to the Switch Mainframe
37
Connect the Power Cord
38
Voltage and Resistance Measurement
38
Connect the Cell
38
Configure the Channel and Function
38
Select Measurement Range
39
Set Sampling Rate
39
Read the Measured Voltage and Resistance
39
Enclosure Potential Measurement
40
Connect the Cell
40
Enclosure Potential Contact Check
40
Positive to Enclosure Voltage
41
Negative to Enclosure Voltage
42
Input and Channel Configuration
44
Front Inputs
44
Multiplexer Cards
45
Built-In Multiplexer Cards
45
External Multiplexer Cards
46
Connect the Cell
50
Channel Configuration
53
Measurement Function
57
DCV
57
Acr
57
Enclosure Potential Contact Check
58
Positive to Enclosure Voltage
59
Negative to Enclosure Voltage
59
Changing Measurement Speed
60
Changing Resistance Range
60
Instrument Setup
61
Language Settings
62
Max Measure Current
62
Comparator
63
Average
65
Trigger
67
Trigger Mode
67
Trigger Delay
68
Input Impedance
69
Remote Interface
70
Power Frequency
73
Self-Calibraion
74
Device Information
75
Restore to Factory Defaults
76
Zero-Adjust
77
Clearing Zero-Adjustment
80
Memory Function
80
Remote Control
81
Connect the Computer
81
Remote Control UI
82
Remote Control Commands
82
System Status Diagram
84
List of Commands
87
Message Reference Interpretation
93
IEEE-488.2 Common Commands
93
Status Reporting Commands
95
System-Related Commands
97
Remote Interface Commands
99
Factory Reset Commands
99
Line Power Frequency Commands
99
Measurement Configuration Commands
100
Calculate Commands
104
Memory Commands
108
Trigger Commands
112
Reading Measured Values Commands
115
Switch Relay Card Commands
117
Remote Command Examples
119
Compound Headers Using a Tree - Usage and Examples
119
Input Channel Slection/Route Scan Programming Examples
120
Memory Programming Examples
129
List of Error Message
131
Maintenance
138
Change the Fuse
138
Calibration
139
Specifications
140
BT5300 Battery Tester
140
Measurement Items
140
Sampling Time
140
Range and Accuracy
140
SW1080 Switch Mainframe
141
SW9010 Multiplexer Card
142
General Specifications
142
Appendix
144
Appendix 1. AC Four-Terminal Method
144
Appendix 2. Precautions for Making Custom Test Cables
145
Making Custom Test Leads for Multiplexer Cards
145
Configuring Battery Probe Tips
145
Appendix 3. Effect of Eddy Currents and Suggested Solution
147
Effect of Eddy Currents
147
Suggested Scheme: Separate the SENSE and SOURCE Cables
147
Suggested Scheme: Use Twisted Pair
148
Suggested Optimization Scheme: Reduce the Overlap of Loops
149
Suggested Optimization Scheme: Use Magnetic Field Shielding Materials
149
Appendix 4. Zero Adjustment
151
Principle of Zero Adjustment
151
Zeroing Using a Zero-Adjust Board
152
Zeroing Using Custom Zero-Adjust Board, Probes or Clip Type Leads
153
Appendix 5. Scan Mode to Improve Test Efficiency
154
The Test Efficiency of OCV Test Benches Is Getting Higher and Higher
154
Comparison of Three Test Methods of OCV Test Bench
154
Example Commands for Scan Mode
155
Appendix 6. Use BT5300 to Measure Internal Resistance, Open-Voltage, and Enclosure Potential
157
Measuring with Front Panel Input Terminals
157
Measuring through Rear Panel Multiplexer Cards
160
Appendix 7. Instrument Installation
164
Introduction
164
Preparation
164
Install a Single Rack-Mount Kit
164
Install a Dual Rack-Mount Kit
165
Overall Dimensions of the Product
167
Appendix 8. SW1080 Appearance
168
Advertisement
Advertisement
Related Products
Fluke B Series
Fluke Series II
Fluke BT520
Fluke BT510
Fluke BT521
Fluke BT21ANG
Fluke 095969588379
Fluke 095969638630
Fluke 095969638647
Fluke 095969638654
Fluke Categories
Measuring Instruments
Test Equipment
Multimeter
Thermometer
Laboratory Equipment
More Fluke Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL