Bit 24: Singleturn system (--> F3x135, x = 1, 2, 3).
Bit 25: Singleturn power down (--> F3x135, x = 1, 2, 3).
Bit 26: Multiturn position 1 (--> F3x136, x = 1, 2, 3).
Bit 27: Multiturn position 2 (--> F3x136, x = 1, 2, 3).
Bit 28: Multiturn system (--> F3x136, x = 1, 2, 3).
Bit 29: Multiturn power down (--> F3x136, x = 1, 2, 3).
Bit 30: Multiturn overflow/underflow (--> F3x136, x = 1, 2, 3).
Bit 31: Multiturn battery (reserved).
Remedy:
- determine the detailed cause of the fault using the fault value.
- replace the encoder if necessary.
Note:
An EnDat 2.2 encoder may only be removed and inserted in the "Park" state.
If an EnDat 2.2 encoder was removed when not in the "Park" state, then after inserting the encoder, a POWER ON
(switch-off/switch-on) is necessary to acknowledge the fault.
F31137
Encoder 1: Internal fault when determining the position
Message value:
Fault cause: %1 bin
Message class:
Hardware/software error (1)
Drive object:
B_INF, ENC, VECTOR_G
Component:
Encoder 1
Reaction:
Vector: ENCODER (IASC/DCBRK, NONE)
Infeed: NONE
Acknowledge:
PULSE INHIBIT
Cause:
A position determination fault has occurred in the DRIVE-CLiQ encoder.
Fault value (r0949, interpret binary):
yyxxxxxx hex: yy = encoder version, xxxxxx = bit coding of the fault cause
For yy = 08 hex (bit 27 = 1), the following bit definition applies:
Bit 1: Signal monitoring (sin/cos).
Bit 8: F1 (safety status display) fault position word 1.
Bit 9: F2 (safety status display) fault position word 2.
Bit 16: LED monitoring iC-LG (opto ASIC).
Bit 17: Fault in the multiturn.
Bit 23: Temperature outside the limit values.
Note:
For an encoder version that is not described here, please contact the encoder manufacturer for more detailed
information on the bit coding.
Remedy:
- determine the detailed cause of the fault using the fault value.
- if required, replace the DRIVE-CLiQ encoder.
F31138
Encoder 1: Internal error when determining multiturn information
Message value:
Fault cause: %1 bin
Message class:
Hardware/software error (1)
Drive object:
B_INF, ENC, VECTOR_G
Component:
Encoder 1
Reaction:
Vector: ENCODER (IASC/DCBRK, NONE)
Infeed: NONE
Acknowledge:
PULSE INHIBIT
Cause:
A position determination fault has occurred in the DRIVE-CLiQ encoder.
Fault value (r0949, interpret binary):
yyxxxxxx hex: yy = encoder version, xxxxxx = bit coding of the fault cause
For yy = 08 hex (bit 27 = 1), the following bit definition applies:
Bit 1: Signal monitoring (sin/cos).
Bit 8: F1 (safety status display) fault position word 1.
Bit 9: F2 (safety status display) fault position word 2.
Bit 16: LED monitoring iC-LG (opto ASIC).
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Propagation: