4 Faults and alarms
4.2 List of faults and alarms
F34804 (N, A)
VSM: CRC
Message value:
%1
Message class:
Hardware/software error (1)
Drive object:
B_INF, VECTOR_G
Component:
Voltage Sensing Module (VSM)
Reaction:
Vector: NONE (OFF1, OFF2, OFF3)
Infeed: OFF2 (NONE, OFF1)
Acknowledge:
IMMEDIATELY
Cause:
A checksum error has occurred when reading-out the program memory on the Voltage Sensing Module (VSM).
Remedy:
- check whether the permissible ambient temperature for the component is maintained.
- replace the Voltage Sensing Module.
Reaction upon N:
NONE
Acknowl. upon N:
NONE
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F34805 (N, A)
VSM: EEPROM checksum error
Message value:
%1
Message class:
Hardware/software error (1)
Drive object:
B_INF, VECTOR_G
Component:
Voltage Sensing Module (VSM)
Reaction:
Vector: NONE (OFF1, OFF2, OFF3)
Infeed: OFF2 (NONE, OFF1)
Acknowledge:
IMMEDIATELY
Cause:
Internal parameter data is corrupted.
Fault value (r0949, interpret hexadecimal):
01: EEPROM access error.
02: Too many blocks in the EEPROM.
Remedy:
- check whether the permissible ambient temperature for the component is maintained.
- replace the Voltage Sensing Module (VSM).
Reaction upon N:
NONE
Acknowl. upon N:
NONE
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F34806
VSM: Initialization
Message value:
-
Message class:
Hardware/software error (1)
Drive object:
B_INF, VECTOR_G
Component:
Voltage Sensing Module (VSM)
Reaction:
Vector: NONE (OFF1, OFF2, OFF3)
Infeed: OFF2 (NONE, OFF1)
Acknowledge:
IMMEDIATELY
Cause:
For the Voltage Sensing Module (VSM), a fault has occurred while initializing.
Remedy:
Replace the Voltage Sensing Module.
A34807 (F, N)
VSM: Sequence control time monitoring
Message value:
-
Message class:
Hardware/software error (1)
Drive object:
B_INF, VECTOR_G
Component:
Voltage Sensing Module (VSM)
Reaction:
NONE
Acknowledge:
NONE
Cause:
Error, timeout in the sequence control on the Voltage Sensing Module (VSM).
Remedy:
Replace the Voltage Sensing Module.