• Connect the 12 V battery to the PAIR control solenoid valve
terminals and check the air flow.
• If air does not flow out, the solenoid valve is in normal condi-
tion.
• Check the resistance between the terminals of the PAIR con-
trol solenoid valve.
Resistance: 18 – 22 Ω at 20 – 30 °C (68 – 86 °F)
\ 09900-25008: Multi-circuit tester set
V Tester knob indication: Resistance (Ω)
INSTALLATION
If the resistance is not within the standard range, replace the
PAIR control solenoid valve with a new one.
Installation is in the reverse order of removal.
• Connect the PAIR control solenoid valve lead wire coupler
and PAIR hoses securely. (10-24)
EMISSION CONTROL INFORMATION 11-7
12V