Suzuki GSX-R1000 2007 Service Manual page 445

Table of Contents

Advertisement

GENERATOR NO-LOAD PERFORMANCE
• Lift and support the fuel tank. (
• Disconnect the generator coupler.
• Start the engine and keep it running at 5 000 r/min.
• Using the multi-circuit tester, measure the voltage between
three lead wires.
If the tester reads under the specified value, replace the gen-
erator with a new one.
09900-25008: Multi-circuit tester set
Tester knob indication: Voltage (~)
Generator no-load performance:
65 V and more at 5 000 r/min (When engine is cold)
REGULATOR/RECTIFIER
• Remove the left under cowling. (
• Disconnect the regulator/rectifier couplers .
• Measure the voltage between the lead wires using the multi
circuit tester as indicated in the table below. If the voltage is
not within the specified value, replace the regulator/rectifier
with a new one. (
09900-25008: Multi-circuit tester set
Tester knob indication: Diode test (
B/R
B/R
1
B/R
0
1
B/R
0
2
B
1
B
2
B
3
B/W
1
B/W
2
1.4 V and more (tester's battery voltage)
NOTE:
If the tester reads 1.4 V and below when the tester probes are
not connected, replace its battery.
5-3)
8-5)
10-40)
Probe of tester to:
B
B
B
2
1
2
0.2 – 0.8 0.2 – 0.8 0.2 – 0.8 0.4 – 1.0 0.4 – 1.0
0.2 – 0.8 0.2 – 0.8 0.2 – 0.8 0.4 – 1.0 0.4 – 1.0
0.6 – 1.2 0.6 – 1.2 0.2 – 0.8 0.2 – 0.8
0.6 – 1.2 0.2 – 0.8 0.2 – 0.8
0.6 – 1.2
0.6 – 1.2 0.6 – 1.2
0.3 – 1.0 0.3 – 1.0 0.3 – 1.0
0.3 – 1.0 0.3 – 1.0 0.3 – 1.0
)
Unit: V
B/W
B/W
3
1
2
0.2 – 0.8 0.2 – 0.8
0
0
ELECTRICAL SYSTEM 9-11
W
W
W
B/W
B/R
1
1
B/R
B/W
2
2
B
2
B
1
B
3

Advertisement