Step 3
1) Remove the AP sensor.
2) Connect the vacuum pump gauge to the vacuum port of the
AP sensor.
Arrange 3 new 1.5 V batteries in series
voltage is 4.5 – 5.0 V) and connect
terminal
and
terminal to the VCC terminal
3) Check the voltage between Vout
if voltage reduces when vacuum is applied up to 53 kPa (400
mmHg) by using vacuum pump gauge. (Below)
\ 09917-47011: Vacuum pump gauge
09900-25008: Multi-circuit tester set
W Tester knob indication: Voltage ()
Is the voltage OK?
• R, G/Y or B/Br wire open or shorted to ground,
or poor
• If wire and connection are OK, intermittent trou-
ble or faulty ECM.
YES
• Recheck each terminal and wire harness for
open circuit and poor connection.
• Replace the ECM with a known good one, and
inspect it again.
If check result is not satisfactory, replace AP sen-
NO
sor with a new one.
4) After repairing the trouble, clear the DTC using SDS tool.
(4-28)
Output voltage (VCC voltage 4.5 – 5.0 V, ambient temp. 20 –
30 °C, 68 – 86 °F)
ALTITUDE
(Reference)
(ft)
(m)
0
0
2 000
610
2 001
611
5 000
1 524
5 001
1 524
8 000
2 438
8 001
2 439
10 000
3 048
terminal to the ground
and ground. Also, check
,
or
connection.
ATMOSPHERIC
PRESSURE
(mmHg)
kPa
760
100
707
94
707
94
634
85
634
85
567
76
567
76
526
70
3
(check that total
.
3
OUTPUT
VOLTAGE
(V)
3.1 – 3.6
2.8 – 3.4
2.6 – 3.1
2.4 – 2.9
FI SYSTEM DIAGNOSIS 4-61
V
ECM coupler (Harness side)
(Black)
(Gray)