Stp Sensor Adjustment - Suzuki GSX-R1000 2007 Service Manual

Table of Contents

Advertisement

STP SENSOR ADJUSTMENT

If the STP sensor adjustment is necessary, measure the sensor
output voltage and adjust the STP sensor position as follows:
• Disconnect the STVA lead wire coupler.
• Remove the air cleaner box cover. (2-4)
• Insert the needle pointed probes to the STP sensor coupler.
• Turn the ignition switch ON.
• Close the secondary throttle valve by finger, and measure the
STP sensor output voltage.
 STP sensor output voltage
ST valve is fully closed: 0.48 – 0.52 V ( Y –  B)
\ 09900-25008: Multi-circuit tester set
09900-25009: Needle pointed probe set
W Tester knob indication: Voltage ()
• Loosen the STP sensor mounting screw.
• Adjust the STP sensor
within the specified value and tighten the STP sensor mount-
ing screw.
\ 09930-11950: Torx wrench
" STP sensor mounting screw: 3.5 N·m (0.35 kgf-m, 2.5 lb-ft)
until the output voltage comes
FUEL SYSTEM AND THROTTLE BODY 5-23
V

Advertisement

Table of Contents
loading

Table of Contents