Handling Firmware Update Errors; Error Message Table - Ricoh D127 Field Service Manual

Hide thumbs Also See for D127:
Table of Contents

Advertisement

10. Confirmation message appears on the LCD.
11. Touch "Yes" to proceed.
12. Reconfirmation message appears on the LCD.
13. Touch "Yes" to uninstall the browser unit.
14. You will see "Uninstalling the extended feature... Please wait.", and then "Completed".
15. Touch "Exit" to go back to the setting screen.
16. Exit "User/Tools" setting, and then turn off the main power switch.
17. Remove the SD card of the browser unit from SD card slot 2 (lower).
18. Overwrite the updated program in the "sdk" folder of the browser unit application with PC.
19. Do the "Installation Procedure" to install the browser unit.

Handling Firmware Update Errors

An error message shows in the first line if an error occurs during a download. The error code consists of
the letter "E" and a number ("E20", for example).

Error Message Table

Code
Meaning
20
Cannot map logical address
21
Cannot access memory
Cannot decompress compressed
22
data
Error occurred when ROM
23
update program started
24
SD card access error
No HDD available for stamp
30
data download
Data incorrect for continuous
31
download
Solution
Make sure the SD card is inserted correctly.
HDD connection incorrect or replace hard disks.
Incorrect ROM data on the SD card, or data is
corrupted.
Controller program abnormal. If the second attempt
fails, replace controller board.
Make sure SD card inserted correctly, or use another
SD card.
HDD connection incorrect or replace hard disks.
Insert the SD card with the remaining data required for
the download, the re-start the procedure.
Using SP Mode
149