Communication Switch 13 – Not used (do not change the settings.)
Communication Switch 14 [SP No. 1-104-021]
No
FUNCTION
Inch-to-mm conversion during
transmission
0
0: Disabled 1: Enabled
1-5 Not used
Available unit of resolution in
which fax messages are received
Bit 7: 0, Bit 6: 0 = mm
6-7
Bit 7: 0, Bit 6: 1 = inch
Bit 7: 1, Bit 6: 0 = mm and inch
(default)
Bit 7: 1, Bit 6: 1 = Not used
Communication Switch 15 – Not used (do not change the settings)
Communication Switch 16 – Not used (do not change the settings)
Communication Switch 17 [SP No. 1-104-024]
No
FUNCTION
SEP (Selective polling) reception
Enabled/Disabled switch
0
0: Disabled / 1: Enabled
COMMENTS
0: In immediate transmission, data scanned in inch format
are transmitted without conversion.
In memory transmission, data stored in the SAF memory in
mm format are transmitted without conversion.
Note: When storing the scanned data into SAF memory,
the fax unit always converts the data into mm format.
1: The machine converts the scanned data or stored data
in the SAF memory to the format which was specified in
the set-up protocol (DIS/NSF) before transmission.
Do not change the factory settings.
For the best performance, do not change the factory
settings.
The setting determined by these bits is informed to the
transmitting terminal in the pre-message protocol
exchange (in the DIS/NSF frames).
COMMENTS
"Enabled" means SEP (Selective polling) is acceptable on
reception.
Bit Switches