3. Appendix: SP Mode Tables
Password Null Not Permit
This SP is referenced only when SP5411-4 is set to "1" (On).
005
[0 to 1/0/1]
0: Password NULL not permitted.
1: Password NULL permitted.
Detail Option
006
Bit 0: Anonymous authorization [0: OFF 1: ON]
*Only bit 0 is used.
5413
Lockout Setting
Lockout On/Off
Switches on/off the lock on the local address book account.
001
[0 to 1/0/1]
0: Off
1: On
Lockout Threshold
002
Sets a limit on the frequency of lockouts for account lockouts.
[1 to 10/5/1]
Cancellation On/Off
Determines whether the system waits the prescribed time for input of a correct user ID and
password after an account lockout has occurred.
003
[0 to 1/0/1]
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if correct user ID and password are entered.
Cancellation Time
Determines the length of time that the system waits for correct input of the user ID and
004
password after a lockout has occurred. This setting is used only if SP5413-3 is set to "1"
(on).
[1 to 999/60/1 min.]