Ricoh D127 Field Service Manual page 178

Hide thumbs Also See for D127:
Table of Contents

Advertisement

6. Troubleshooting
[0D05]
B
[50A1]
B
[50A2]
B
Self-diagnostic error: HDD (Hard Disk Drive)
[XXXX]: Detailed error code
822
When the main switch is turned on or starting the self-diagnostic, the HDD stays busy for
the specified time or more.
[3003]
C
[3004]
C
823
Self-diagnostic Error: NIB
[6101]
C
176
Timer error between ASIC and CPU
The CPU checks if the ASIC timer
works properly compared with the
CPU timer. If the ASIC timer does not
function in the specified range, this
SC code is displayed.
Video bridge device (ASIC) error 1
The CPU does not detect the video
bridge device.
Video bridge device (ASIC) register error 1
The CPU detects the video bridge
device, but detects error data from
the video bridge device.
Timeout error
Command error
MAC address check sum error
The result of the MAC address check
sum does not match the check sum
stored in ROM.
• System firmware problem
• Defective RAM-DIMM
• Defective controller
• Reinstall the controller system
firmware.
1. Replace the RAM-DIMM.
2. Replace the controller board.
• Defective I/F between the video
bridge device and controller
1. Replace the controller board.
• Defective I/F between the video
bridge device and controller
1. Replace the controller board.
• Loose connection
• Defective HDD
• Defective controller
1. Check that the HDD is correctly
connected to the controller.
2. Replace the HDD or the controller
• Defective controller
1. Replace the controller.

Advertisement