Ricoh D127 Field Service Manual page 232

Hide thumbs Also See for D127:
Table of Contents

Advertisement

3. Appendix: SP Mode Tables
1105 32 Waiting: Center Upper: Plain1
1105 34 Waiting: Center Upper: Plain2
1105 36 Waiting: Center Upper: M - Thick
1105 38 Waiting Center Upper: Thick
1106
Fusing Temperature Display
1106 1 Roller Center
In The Machine at Power On
1106 3
Displays the thermistor temp. at power on.
1108*
Control Period Setting
1108 1 Warming-up
1108 2 Print
1108 3 Wait
1108 4 Print Start
1108 5 Print Start Time
1112
Image Process Temp. Correction
1112 1 Temp.: Normal: Level1
1112 2 Temp.: Normal: Level2
1124
CPM Down Setting
Low: Down Temp
1124 1
Sets the temperature for the trigger of CPM down.
Low: Up Temp
1124 2
Sets the temperature for the trigger of CPM up.
24
[0 to 60 / 40 / 1 °C/step]
Additional value to each paper type setting
temp.. The sum at which or less, registration
waiting starts.
[-20 to 250 / 0 / 1 °C/step]
[-20 to 250 / 0 / 1 °C/step]
[100 to 2000 / 100 / 100 msec/step]
[100 to 2000 / 1000 / 100 msec/step]
[100 to 2000 / 1000 / 100 msec/step]
[100 to 2000 / 200 / 100 msec/step]
[0 to 999 / 5 / 1 sec/step]
[-25 to 10 / 0 / 1 °C/step]
Sets the additional temperature
[-50 to 0 / -25 / 1 °C/step]
[-50 to 0 / -5 / 1 °C/step]

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-c5D128

Table of Contents