2105*
LD Power Adjustment
2105 1 [60 to 140 / 100 / 0.1 %/step]
2109*
Test Pattern
Pattern Select
This SP has the test patterns as below.
0
None
1
Vertical Line (1dot)
2
Vertical Line (2dot)
3
Horizontal Line (1dot)
4
Horizontal Line (2dot)
2109 1
5
Grid Vertical Line
6
Grid Horizontal Line
7
Grid Pattern Small
8
Grid Pattern Large
9
Argyle Pattern Small
10
Argyle Pattern Large
11
Independent Pattern (1dot)
12
Independent Pattern (2dot)
Pattern Density
2109 2
Sets the density applying to test patterns
LD Power Adj.
2152*
Adjusts each area LD power. Higher becomes stronger LD. Lower becomes dimmed.
2152 1 LD1 Area 0
2152 2 LD1 Area 1
2152 3 LD1 Area 2
13
Independent Pattern (4dot)
14
Trimming Area
15
Hound's Tooth Check (Horizontal)
16
Hound's Tooth Check (Vertical)
17
Black Band (Horizontal)
18
Black Band (vertical)
19
Checker Flag Pattern
20
Grayscale (Vertical)
21
Grayscale (Horizontal)
22
Two Beam Density Pattern
23
Full Dot Pattern
24
All White pattern
[0 to 15 / 15 / 1 /step]
[75 to 125 / 100 / 0.1 %/step]
[75 to 125 / 79.9 / 0.1 %/step]
[75 to 125 / 79.9 / 0.1 %/step]