4. Replacement and Adjustment

Laser Unit

1. PSU assembly (
2. Toner bottle holder
3. Remove 2 of the mylars (Film) sealing the holes on the bottom of the toner bottle rail.
4. Laser unit [A] (
5. Replace the mylars (Film) with new ones.
• The mylars are necessary to seal the holes in order for the laser unit not to be tainted with toner
powder.