Over-limit OP panel administrative record error
The record, which composes the
994-00
D
display items and which is controlled
by the service layer, is over the certain
limit.
Application function selection error
The application selected by a key
997
C
press on the operation panel does not
start or ends abnormally.
Application start error
After switching the machine on, the
998
B
application does not start within 60 s.
(No applications start or end
normally.)
• In using the operation panel, if
operating reaches deep layer with
multiple applications active, the
record may go over the limitation.
• Software for that application is
defective
• An option required by the
application (RAM, DIMM, board) is
not installed.
• Too complicated nest of the fax
group address
1. As for the fax operation problem,
simplify the nest of the fax group
address.
• Software for that application is
defective
• An option required by the
application (RAM, DIMM, board) is
not installed.
1. Check the setting of SP5875-001. If
the setting is set to "1 (OFF)", change
it to "0 (OFF)".
SC Tables
189