4. Replacement and Adjustment
• The diagram shows the paper on the copy tray. Note that the paper is output with the face
down.
3. Adjust the blank margin (SP2-103).
SP2-103-001 (Leading Edge) [A]
SP2-103-002 (Trailing Edge) [B]
SP2-103-003 (Left Side) [C]
SP2-103-004 (Right Side) [D]
• The "Left Side" and "Right Side" comes to your left-hand side and right-hand side respectively
when you view the copied image with the leading edge upwards.
4. Select "Cancel" in SP2-109-001 after finishing the adjustment procedure.

Adjusting Main-Scan Magnification

Use the Grid Pattern (Grid Vertical Line) (SP2-109-001 > 5) for this adjustment.
SP2-102-001 (Main scan Mag.)
1. Print out the test pattern.
2. Measure the sides of squares. Each side should be 2.7-mm long.)
3. Adjust the main-scan magnification (SP2-102-001: Main Scan Mag.).
4. Select "Cancel" in SP2-109-001 after finishing the adjustment procedure.

Scanning

Preparation:
• Before adjusting scanning, adjust printing (
• To adjust scanning, use the A4 test chart.
136
SP
SP
Specification
3 +1/-3 mm
3 +1/-3 mm
2 ± 2 mm
2 ± 2 mm
Specification
0 ± 0.5%
p.134 "Printing").