3. Appendix: SP Mode Tables
1103*
Fusing Idling
Fusing Idling
1103 1
Enables or disables the contact-release control.
Reload Temp: Center
1103 2
Sets the degree at which or less reload becomes ON.
Threshold
1103 3
Sets threshold-degree for switching forced reload to temperature-judging reload.
Fusing Temperature Adjustment
1105*
Adjusts the target fusing temperature. Note that the thermistor is at the center of the hot
roller.
1105 1 Roller Center: Plain1
1105 3 Roller Center: Plain2
1105 5 Roller Center: M - Thick
Thick Paper – Roller Center
1105 7
Sets the additional temperature to SP1105-001's degree for thick paper print.
(i.e.: SP1105-001= 140, This SP= 10, 140+10= 150 degree)
Center Minus: Thin
1105 9
Sets the subtractive temperature to SP1105-001's degree for thin paper print.
(i.e.: SP1105-001= 140, This SP= 5, 140-5= 135 degree)
Energy Saver
1105 11
Sets the fusing temperature on energy saving mode.
1105 12 Wait Temp: Center
1105 13 Print Ready
Thresh: S1
1105 14
Sets standard temperature used for the environment judge.
*About the judge, refer to SP1105-015.
22
[0 = No / 1 = Yes]
[90 to 140 / 120 / 1 °C/step]
[60 to 160 / 100 / 1 °C/step]
[120 to 200 / 140 / 1 °C/step]
[120 to 200 / 145 / 1 °C/step]
[0 to 40 / 10 / 1 °C/step]
[0 to 20 / 5 / 1 °C/step]
[0 to 80 / 60 / 1 °C/step]
[140 to 160 / 150 / 1 °C/step]
[140 to 180 / 160 / 1 °C/step]
[0 to 50 / 16 / 1 °C/step]