Procedure 4
Enabling Full Duplex mode
1
Reset the phone by disconnecting and re-connecting power.
2
When the Nortel logo appears, press each of the soft keys in sequence.
See Procedure 3 on
3
If no other configuration changes are required, press OK repeatedly until
the Duplex network option appears.
4
Select 1 to enable Full Duplex mode.
5
When the Speed option appears, select one of the following:
0 for 10 Mbps
1 for 100 Mbps (default)
6
Select OK to confirm the change.
7
Restart the IP Phone 2001. The firmware settings are read and are
applied to UPLINK and the PC Ethernet Port.
When the IP Phone is restarted, the firmware reads the setting for Full Duplex
mode and sets the LAN Ethernet port, PC Ethernet port, duplex, and speed
accordingly.
Use Procedure 5 to confirm activation of Full Duplex mode.
Procedure 5
Checking Ethernet Statistics
1
Double-click the Services key. The Network Diagnostics menu appears.
2
Select Ethernet Statistics.
If Full Duplex mode is active, the following is displayed:
— Link: UP
— Duplex: Full
— Speed: 10 (Mb) or 100(Mb)
December 2006
page 68
to enable Full Duplex mode.
page
61.
End of Procedure