Others (Network Device Related) - Konica Minolta bizhub C200 Service Manual

Hide thumbs Also See for bizhub C200:
Table of Contents

Advertisement

Field Service Ver. 2.0 Dec. 2008
8.4.9

Others (Network device related)

Item
Condition
No.
1
When the power
switch is on,
[ERROR!!] displays
on the touch panel
screen.
2
"Registering in net-
work. Other opera-
tions halted. Please
wait". is displayed.
Possible cause
Failure in PKG connection
Unit error
Administrator is logging in
from the Assistant tool for
C200.
8. Troubleshooting
Action to be taken
Reattach MEMU/1 or MEMU/2.
Replace MEMU/1 or MEMU/2.
Wait until the administrator finishes the
operation and logs out.
In case that the administrator has closed
the browser without logout operation, ask
the administrator to log out from the Assis-
tant tool for C200.