7. Soft Switch
MODE
Bit:
056
Bit
Feature
2
Select sending time of
ANSam.
1
0
MODE
Bit:
057
Bit
Feature
7
Select the time from when
line is blocked to when
6
ANSam (modified answer
5
tone) TX starts.
4
3
2
1
0
66
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
1 1 0 0
Logic
0
Bit 2-0:
000
001
010
011
100
101
110
111
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 1
1 0 0 1
Logic
0
Bit 7-0:
00000000 Not available
00000001 100 msec
00011001 2500 msec
11111111 25500 msec
Field Service Ver. 2.0 Dec. 2008
HEX: 0C
Description
1
2.0 sec
2.5 sec
3.0 sec
3.5 sec
4.0 sec
5.0 sec
6.0 sec
Not available
HEX: 19
Description
1
|
Specify the time from
when line is blocked to
|
when ANSam TX starts.