Printer Monocolor: Uneven Density In Main Scan Direction - Konica Minolta bizhub C200 Service Manual

Hide thumbs Also See for bizhub C200:
Table of Contents

Advertisement

Field Service Ver. 2.0 Dec. 2008
19.3.18

Printer monocolor: uneven density in main scan direction

A. Typical faulty images
B. Troubleshooting procedure
Step
Section
Imaging unit
1
2
PH unit
3
Transfer roller
4
Transfer belt unit Transfer belt unit makes positive
5
6
7
Check item
The surface of the PC drum is
scratched.
Dirty on the outside.
The surface of the PH window is
dirty.
Check that the spring does not
come off during the pressure oper-
ation of the transfer roller.
contact with plates on rails.
Is abnormality found in the cam
gear?
The problem has been eliminated
through the checks of steps up to 6.
19. Image quality problem
Result
Action
YES Change imaging unit.
YES Clean.
YES Clean with cleaning jig.
NO
Correct.
Change transfer roller unit.
NO
Check and correct contacts.
YES Change transfer belt unit.
NO
Change imaging unit.
→ Change PH unit.
→ Change high voltage unit.
A02EF4C520DA
393