5. Service Mode

5.
Service Mode
5.1

Service Mode setting procedure

See P.158 of the main body service manual.
5.2

ADF Adjustment

5.2.1

Zoom

Functions
• To set the zoom ratio in the main and sub scan directions of the ADF.
Use
• When ADF has been replaced.
Adjustment
• A (Main scan direction): 287 ± 1.4 mm (± 0.5 %)
specification
• B (Sub scan direction): 190 ± 1.0 mm (± 0.5 %)
Adjustment
• x 0.990 to x 1.010 [Cross Direction Adjustment]
range
• x 0.980 to x 1.020 [Feed Direction Adjustment]
2. Call the Service Mode to the screen.
See P.158 of the main body service manual.
3. Touch [Machine Adjustment] → [Scan Area] → [Test Copy].
4. Touch [1 > 1] for simplex/duplex and [OFF] for mixed original and then press the start
key.
7. Touch [OK].
8. Touch [ADF Adjustment] → [Zoom].
34
[1]
A0EYF3C500DA
B
A
A0EYF3C501DA
Field Service Ver. 1.0 Jun. 2008
1. Load the test chart [1] in the ADF.
5. Check that the lengths of the refer-
ence lines reproduced on the copy, A
(Main scan direction) and B (Sub
scan direction), meet the following
specifications.
6. If the reference line lengths A and B
are not within the specifications,
make the following adjustment.

Advertisement