2.3.3

Separation roller assy

1. Remove the right door.
See P.5
[1]
[2]
[1]
[2]
6
[2]
[1]
A093F2C500DA
[3]
A093F2C501DA
[3]
[1]
A093F2C502DA
Field Service Ver. 2.0 Dec. 2008
2. Remove two screws [1] and remove
the separation roller mounting
bracket assy [2].
3. Remove two C-rings [1] and the
shaft [2], and remove the separation
roller fixing bracket assy [3].
NOTE
• Be careful not to lose spring at this
time.
4. Remove the C-ring [1], the guide [2],
and remove the separation roller
assy [3].