Field Service Ver. 2.0 Dec. 2008
8. Reinstall the cover of the slot.
9. Turn ON the main power switch and the sub power switch.
10. Select [Admin.] → [Firmware Version].
11. Check that the firmware version has been updated.
2.2
Firmware rewriting by the Internet ISW
1
2.2.1
Outline
• [Internet ISW] is the system which gives the instruction for updating the firmware with the
CS Remote Care, so the main body will automatically receive the firmware from the pro-
gram server over a network for updating.
2.2.2
Service environment
The following conditions are necessary for using the Internet ISW function.
• The main body is connected to such a network environment that the firmware can be
downloaded on the internet using the http protocol.
The "Internet ISW" will not operate under the following conditions.
• Main power switch is set to OFF.
• Sub power switch is set to OFF.
• The main body has the job currently performing.
• Modes other than normal mode are used.
• Machine has a paper jam.
• The version of firmware provided from the program server and MFBU board on the
machine are not compatible with each other.
2.2.3
Preparations
• For using the Internet ISW, the network parameter, program server address as well as
firewall address need to be set to the main body.
• For details of each setting item, refer to Adjustment/Setting "Internet ISW".
See P.315 of the main body service manual.
A. Internet ISW
1. Call the service mode to the screen.
2. Touch [Internet ISW]
2. Firmware upgrade
A02FF2E540DA
5
1