Field Service Ver. 2.0 Dec. 2008
6.3.32
Flat cable of the exposure unit
A. Removal procedure
1. Remove the exposure unit.
See P.76
[1]
B. Reinstall procedure
320 mm ±1 mm
[2]
[1]
A02FF2C133DA
A02FF2C537DA
A02FF2C523DA
2. Remove the screw [1], and remove
the cable guide [2].
3. Disconnect the flat cable [1].
1. Mark the flat cable at the position as
shown in the left illustration.
6. Other
79