11
MAINTENANCE
■ Frequency calibration
A very accurate frequency counter is required to
calibrate the frequency of the transceiver.
However, a rough check may be performed by
receiving radio station WWV, WWVH, or other
standard frequency signals.
CAUTION: The IC-7600 has been thoroughly
adjusted and tested at the factory before being
shipped. You should not have to re-calibrate it.
q Push [SSB] to select the USB mode.
w Hold down [PBT-CLR] for 1 second to clear the
PBT setting and make sure that the RIT/∂TX
function is not activated.
e Set the frequency to the standard frequency station
minus 1 kHz.
• When receiving WWV or WWVH (at 15.00000 MHz) as
a standard frequency, set the operating frequency for
14.99900 MHz.
• Other standard frequencies can be used.
r Push [EXIT/SET] several times to close any multi-
function screens, if necessary.
t Push [SET] (F-6) to select the set mode menu
screen.
y Push [OTHERS] (F-5) to select the Others set
mode.
u Push [Y] (F-1) several times to select the
"Calibration Marker" item.
i Rotate the main dial clockwise to turn the
calibration marker ON.
o Push [EXIT/SET] once to return to the set mode
menu screen.
!0 Push [ACC] (F-2) to select the accessory set
mode.
!1 Push [Z] (F-2) several times to select the "REF
Adjust" item.
!2 Rotate the main dial to adjust for a zero beat with
the received standard signal as shown at right.
• Zero beat means that two signals are exactly the same
frequency, resulting in a single tone being emitted.
!3 Turn the calibration marker OFF in the Others set
mode.
!4 Push [EXIT/SET] twice to exit the set mode.