5.3 Installation

For adaption to the production line several works have to be carried out and operating
parameters have to be set before start of operation.

5.3.1 Mains supply

Mains supply!
The device does not have a mains switch and should be only
connected to an easy accessible socket close to the installation
location!
The LEIBINGER JET2 neo should be connected to AC voltage 100-240 V AC, 50-60
Hz with an appropriate plug. The socket should be provided with a clear designation
(e.g.: JET2 neo).
After connecting to the mains power supply the initialization of the device will be
carried out automatically. After this process the JET2 neo is ready for operation.
You will find further information regarding the initialization in the
chapter Initialization of device!

5.3.2 Grounding (Potential equalization)

Grounding (Potential equalization)!
In case of a non existing grounding or that the grounding of the
printer is not carried out properly, this could cause serious injury or
death and it can also cause malfunctions or damages at the printer!
These dangers or demolitions can happen for example because of
electrostatic discharge (ESD) or potential difference.
Specially for countries without existing protected earth connection, there is a
special grounding point located at the side of the printer.
This threaded socket must be connected to ground if there is no ground pin in the
mains socket/plug.
The threaded case is sealed inwards and thus IP 65 conform. With a screw and a
ring terminal (cable lug) the grounding can be fixed easily.
JET2 neo
Transport/Start up
Page 33
Release R1.07 en