Sam4s SPS-300 Series Operator's And Programming Manual page 138

Electronic
Hide thumbs Also See for SPS-300 Series:
Table of Contents

Advertisement

Program Backup and Load
You can use an SD flash memory card to backup and load (restore) the full program.
NOTE: The program data is saved in a separate folder on the SD card named with the
store name that is set on page 18 of system options. Note that the default store name is
"STORE_A". See page 137 for more information about the store name.
Backing Up the Program to an SD Card
Restore Program from the SD Card
CAUTION: Memory allocation must be set the same as the saved program. Be sure to
print out the memory allocation so that it can be re-entered before restoring the program.
138 • S-Mode Programming
1. Insert the SD card in the register's SD slot.
2. Turn the control lock to the S position.
3. From the second page of the Service Mode menu, select "9 SD Card
Operation".
4. From the SD Card Operation menu select "1 Program Backup". The SPS-300
will write the program files to the folder: SPS300/PRGBACK/STORENAME
(where store name is the name programmed on page 18 of system options.) In
the example below, the store name is "1719".
5. After a short pause, the register will print confirmation of the successful upload
with the message "UPLOAD PASS" for each program segment. Below is an
Explorer view of the backed-up files.
1. Set the store name to match the name of the store folder you wish to restore.
2. Insert the SD card in the register's SD slot.
3. Turn the control lock to the S position.
4. From the second page of the Service Mode menu, select "9 SD Card
Operation".
5. From the SD Card Operation menu select "2 Program Load".
6. The register will print confirmation of the successful upload with the message
"DOWNLOAD PASS" for each program segment.
SAM4s SPS-300 Operator's & Programming Manual v1.34

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sps-320Sps500