D-Link xStack DGS-3600 Series Cli Manual page 258

D-link xstack dgs-3600 series layer 3 gigabit ethernet managed switch
Hide thumbs Also See for xStack DGS-3600 Series:
Table of Contents

Advertisement

xStack DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch CLI Manual
config sflow analyzer_server
Restrictions
Example usage:
To configure the sFlow server:
DGS-3627:5# config sflow analyzer_server collectoraddress 10.90.90.9
Command: config sflow analyzer_server collectoraddress 10.90.90.9
Success.
DGS-3627:5#
delete sflow analyzer_server
Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To delete an sFlow analyzer server:
DGS-3627:5# delete sflow analyzer_server 1
Command: delete sflow analyzer_server 1
Success.
DGS-3627:5#
timeout <sec 1-2000000> - Used to specify the timeout for the
Analyzer server. When the server times out, all sFlow samples and
counter polls associated with this server will be deleted. The user
may set a time between 1 and 2000000 seconds with a default
setting of 400 seconds.
collectoraddress <ipaddr> - The IP address of the sFlow Analyzer
Server. If this field is not specified, the entry will become 0.0.0.0 and
therefore the entry will be inactive. Users must set this field.
collectorport <udp_port_number 1-65535> - The destination UDP
port where sFlow datagrams will be sent. The default setting for this
field is 6343. Only one Analyzer Server address can be set for one
UDP Collector Port.
maxdatagramsize <value 300-1400> - This field will specify the
maximum number of data bytes that can be packaged into a single
sFlow datagram. Users may select a value between 300 to 1400
bytes with a default setting of 1400 bytes.
Only administrator-level and operator-level users can issue this
command.
Used to delete an sFlow analyzer server set on the switch.
delete sflow analyzer_server <value 1-4>
This command will delete a previously created sFlow analyzer
server.
<value 1-4> - Enter the value identifying the analyzer to be deleted
here.
Only administrator-level and operator-level users can issue this
command.
255

Advertisement

Table of Contents
loading

Table of Contents