Switch Off Procedure - h/p/cosmos 150/50 mercury Operating And Service Manual

Running machine series
Table of Contents

Advertisement

Devices for sports and fitness before manufacturing date 12/2007:
The running machine can be switched on directly at the expulsion fuse on the FrontTerminal (frontal section below
the hood) to the setting "stand-by mode".
If the emergency stop has been activated, a flashing notice „PULL STOP" appears on the display.
Expulsion fuse and
main switch 2- or 3-pole
Oversize running machines (venus
Before the white "ON" push button can be pressed, the red "main switch" has to be turned 90° as shown on above
picture right. Then after a delay time of approx. 1 to 2 minutes (lamp is blinking) the machine can be powered on
by pressing the white "ON" push button.
5.3

Switch off procedure

Switch off the running machine by pressing the black or red "OFF" push button at the UserTerminal (some models on the
front of the device). The indicator light within the key extinguishes. For some models the location of the ON-/OFF-key may
also be the UserTerminal. Oversized treadmills "venus" and "saturn" are switched off by turning the red main switch. Devices
for sports and fitness manufactured before 12/2007 can be switched off directly with the expulsion fuse at the FrontTerminal
(frontal section below the hood).
The ON-/OFF intervals must not be shorter than 1-2 minutes (for models with 3-phase
N
connection: 2-3 minutes). This may otherwise lead to interference and/or failure of the backup
and/or data loss and/or data corruption.
Models for medical application with the isolation transformer have an inrush current limiter
N
(surge guard). Too short ON/OFF intervals will lead to a deactivation of the inrush current limiter
and result in an overload of the circuit fuse.
If the device is used daily, we recommend switching iton in the morning and leave itin stand-by
N
mode during the day.
Press the emergency stop only in case of danger.
N
The emergency stop is not to be used as a normal stop key.
N
© 2012 h/p/cosmos sports & medical gmbh
ON / OFF button
with control lamp
and saturn
®
file: n:\article\cos14310m5-v1_06hpc-en\20120504_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.docx
email@h-p-cosmos.com
ON / OFF button
until 2003
) running surface 200...300/75...125cm onwards:
®
created 04.05.2012
printed 04.05.2012
operation
Main switch from construction
size running surface
200...300/75...125cm onwards
page: 26 of 191