h/p/cosmos 150/50 mercury Operating And Service Manual page 68

Running machine series
Table of Contents

Advertisement

OP27
Minimum acceleration and
deceleration level
The selected minimum level is valid
for all acceleration and deceleration
processes in all modes and profiles.
OP28
Maximum acceleration and
deceleration level
The selected maximum level is valid
for all acceleration and deceleration
processes in all modes and profiles
OP29
Standard acceleration and
deceleration level for RS 232
interface
OP40
Locking and unlocking of the
treadmill
OP41
Locking and unlocking the manual
mode
OP42
Locking and unlocking the profile
mode
OP43
Locking and unlocking the cardio
mode
OP44
Locking and unlocking the test mode OFF = test mode is locked / not accessible
© 2012 h/p/cosmos sports & medical gmbh
§
modes and profiles (standard: level 1)
Level of settings: 1 ... 5 but not higher than the value in option 28.
Due to safety reasons, the acceleration / deceleration levels 5, 6 and
7 can not be selected. Note: The selected acceleration and
deceleration level is NOT valid for control and operation via RS232-
interface. In this case the acceleration and deceleration level is set in
option no. 29 resp. set in the corresponding command of the
h/p/cosmos coscom protocol.
§
modes and profiles (standard: level 4)
Note: Due to safety reasons, the acceleration / deceleration levels 5,
6 and 7 can only be selected if the safety of the subject is provided for
by the use of the fall prevention (e. g. by the safety arch). The
maximum acceleration and deceleration level is NOT valid for control
and operation via V24/RS232 interface. In this case the acceleration
and deceleration level is set in option no. 29 resp. set in the
corresponding command of the h/p/cosmos coscom protocol.
The selected acceleration and deceleration level is valid for control
and operation via RS232 interface. This option is very helpful if the
peripheral equipment (e.g. ECG, ergospirometry, PC) does not offer a
menu for acceleration and deceleration levels.
§
deceleration level for all speed commands via RS 232. The maximum
adjustable value depends on the setting of option 28.
Note: If the peripheral equipment sends an acceleration and
deceleration command via the h/p/cosmos coscom protocol, the
selected level in option number 29 is not valid for these speed
commands.
OFF = After switching on, the treadmill is completely locked / not
accessible. To unlock the treadmill, press the buttons +, - and START
simultaneously. While locked the display shows "no ACCESS"
ON = treadmill is unlocked / accessible (standard)
OFF = manual mode is locked / not accessible
ON = manual mode is unlocked / accessible (standard)
OFF = profile mode is locked / not accessible
1 ... 6 = profile mode is unlocked / accessible up to the selected
profile number standard: 6
Example: selected profile number = 3: The profiles 1-3 can be
selected, the profiles 4 – 6 can not be selected
OFF = cardio mode is locked / not accessible
ON = cardio mode is unlocked (standard)
1 ... 94 = test mode is unlocked / accessible up to the selected test
profile number standard: 24
selected test number = 5: The test profiles 1-5 can be selected, the
test profiles 6 – 94 can not be selected
file: n:\article\cos14310m5-v1_06hpc-en\20120504_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.docx
email@h-p-cosmos.com
blinking, reports the min. acceleration / deceleration for all
blinking, reports the max. acceleration / deceleration for all
blinking, reports: 1 ... 5, (standard: 1) for the acceleration and
created 04.05.2012
printed 04.05.2012
operation
page: 68 of 191

Advertisement

Table of Contents
loading

Table of Contents