h/p/cosmos 150/50 mercury Operating And Service Manual page 61

Running machine series
Table of Contents

Advertisement

Program steps of a user-defined profile (see previous page)
Initiation: Running machine is in standby mode.
Step no. Activity
[01]
Select test mode
[02]
Confirm test mode
[03]
Select program no.
[04]
Confirm program no.
[05]
Select speed 5.0 km/h
[06]
Confirm speed
[07]
Confirm distance 0 (this step is
programmed after time)
[08]
Select time 5 minutes
[09]
Confirm time
[10]
Confirm time - 00 seconds
[11]
Confirm elevation 0 %
[12]
Confirm acceleration level 1
[13]
Select speed 8.0 km/h
[14]
Confirm speed
[15]
Confirm distance 0 (this step is
programmed after time)
[16]
Select time 2 minutes
[17]
Confirm time
[18]
Select time 30 seconds
[19]
Confirm time
© 2012 h/p/cosmos sports & medical gmbh
LED mode is flashing.
Keys
a
d
or
c
a
d
or
until Pr. 21
c
for at least 5 sec.
a
d
or
c
c
a
d
or
c
c
c
c
a
d
or
c
c
a
d
or
c
a
d
or
c
file: n:\article\cos14310m5-v1_06hpc-en\20120504_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.docx
email@h-p-cosmos.com
Response / Display
Selection of mode (manual, profile, cardio, test)
until
test is flashing
$
indicates program no. Pr. 1 is flashing
$
indicates program no. Pr. 21 is flashing
=
indicates speed: 0.0 is flashing
%
indicates program step St. 1
§
indicates distance: 0 is flashing
!
indicates time (minutes): 0:00 is flashing
!
indicates time (seconds): 5:00 is flashing
$
indicates elevation: Value "0.0" is flashing
"
indicates acceleration level: Acc. 1 is flashing
=
indicates speed: 0.0 is flashing
%
indicates program step St. 2
§
indicates distance: 0 is flashing
!
indicates time (minutes): 0:00 is flashing
!
indicates time (seconds): 2:00 is flashing
$
indicates elevation: 0.0 is flashing
created 04.05.2012
printed 04.05.2012
operation
page: 61 of 191

Advertisement

Table of Contents
loading

Table of Contents