h/p/cosmos 150/50 mercury Operating And Service Manual page 137

Running machine series
Table of Contents

Advertisement

Dimension of running surface
length x width
Dimension frame
length x width x height
Track access height from floor
Weight of device
Weight load limits to floors
(traffic load to DIN 1055 part 3)
Max. permissible user weight
Environmental conditions:
Transport and storage
Environmental conditions:
Operation
Pollution degree
Central lubrication system
Number of stored programmes
RS232 Digital interface / serial port
(USB-converter optional)
Heart rate measurement and heart
rate dependent endurance control
PC software
Reverse belt rotation
Safety Arch with chest belt
system***
Handrails
Arm support / additional keyboard
* Overload and weak power supply (undervoltage) could lead to higher discrepancies concerning the speed display or dripping of the fuse.
** The time of operation of the elevation motor (TO = 15 %) converts to approx. 5 full elevation cycles. Overload can result in temporary tripping of the fuse,
but can be used again after short cool down period. Treadmills of the h/p/cosmos saturn series built approx. before January 2007 have a maximum
elevation of 25 %.
*** For maximum stress tests and with oversize running machines (track sizes) a safety facility (e.g. a safety arch with chest belt system) is necessary and
highly recommended. When using a front-bar handrail (crossbar), the speed is limited to 5 km/h for safety reasons. Data of weight and measurements can
deviate.
Ask for further details and optional equipment or visit www.h-p-cosmos.com. Subject to technical alterations without prior notice. E & OE.
© 2012 h/p/cosmos sports & medical gmbh
1700 x 650 mm
2300 x 1050 x 1450 mm
(UserTerminal + 150 mm width)
360 kg
370 kg
In case of any further questions related to load limits onto floors, please ask our service department.
temperature: –30...+50 °C, humidity: 0...95 % - without condensation
barometric pressure: 700...1060 hPa
temperature: +10...+40 °C (deviation on request), humidity: 30...70% - without condensation
(up to 95% on request), barometric pressure: 700...1060 hPa
Maximum operating altitude: approx. 10,000 feet (3000m), without pressurization
Degree 2: Normally only nonconductive pollution. Temporary conductivity caused by condensation is to be expected.
6 training profiles / 10 test profiles / 8 user definable profiles
COM1: standard
COM2: optional
COM3: optional (standard for service)
COM4: optional
POLAR, 1 channel receiver, ECG precisely
h/p/cosmos para control
options: h/p/cosmos para graphics
option
option
file: n:\article\cos14310m5-v1_06hpc-en\20120504_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.docx
email@h-p-cosmos.com
230 mm
370 kg
380 kg
6.4 kN/m²
200 kg (deviation on request specially made)
manual
included
®
and h/p/cosmos para analysis
®
option
option
option
options: short, long, crossbar (standard)
option
created 04.05.2012
printed 04.05.2012
technical data
1900 x 650 mm
2500 x1050 x 1450 mm
(UserTerminal + 150 mm width)
400 kg
6.1 kN/m²
COM1 and COM2: standard
COM3: optional (standard for
service)
COM4: n.a. (used for POLAR
W.I.N.D.)
POLAR W.I.N.D. with WearLink
transmission range approx. 10 m
h/p/cosmos para control
h/p/cosmos para graphics
®
standard
page: 137 of 191