h/p/cosmos 150/50 locomotion de med Operating Instructions And Service Manual

Hide thumbs Also See for 150/50 locomotion de med:
Table of Contents

Advertisement

Operating instruction and service manual
h/p/cosmos running-machine-series 5.0
Running machines
h/p/cosmos mercury
h/p/cosmos mercury med
h/p/cosmos quasar
h/p/cosmos quasar med
h/p/cosmos pulsar
h/p/cosmos pulsar 3p
h/p/cosmos stellar
h/p/cosmos stellar med
h/p/cosmos stratos
h/p/cosmos stratos med
incl. lt-models
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
running machine
manual
Running machines
h/p/cosmos 150/50 locomotion E med
h/p/cosmos 150/50 locomotion DE med
h/p/cosmos venus - all sizes
h/p/cosmos saturn - all sizes
Manual-version
MCU5 -V1.04
Revision 20080901
manual order-no.:
[cos14310m5-v1.04hpc-en]
h/p/cosmos sports & medical gmbh
phone +49 / 86 69 / 86 42 0
fax +49 / 86 69 / 86 42 49
© 2008 h/p/cosmos sports & medical gmbh
Development, production, sales & service
h/p/cosmos sports & medical gmbh
Am Sportplatz 8
DE 83365 Nussdorf-Traunstein
Germany
phone +49 / 86 69 / 86 42 0
fax +49 / 86 69 / 86 42 49
service@h-p-cosmos.com
www.h-p-cosmos.com
Am Sportplatz 8
DE 83365 Nussdorf-Traunstein / Germany
email@h-p-cosmos.com
www.h-p-cosmos.com
created 01.09.2008
printed 08.10.2008
page: 1 of 176

Advertisement

Table of Contents
loading

Summary of Contents for h/p/cosmos 150/50 locomotion de med

  • Page 1 DE 83365 Nussdorf-Traunstein / Germany phone +49 / 86 69 / 86 42 0 fax +49 / 86 69 / 86 42 49 email@h-p-cosmos.com www.h-p-cosmos.com file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh created 01.09.2008 printed 08.10.2008 page: 1 of 176...
  • Page 2 In case of alterations of the device or the additional equipment always the actual version of the manual or the according additional information has to be considered. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 3: [1.] Introduction

    Subject to alterations without prior notice, errors and omissions excepted. E & OE. We wish you a lot of fun and success while exercising and working with your h/p/cosmos running machine. Franz Harrer President h/p/cosmos sports &...
  • Page 4 150/50 locomotion DE med h/p/cosmos mercury h/p/cosmos quasar h/p/cosmos pulsar h/p/cosmos venus & h/p/cosmos saturn file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 4 of 176...
  • Page 5: Table Of Contents

    [3.H1] Professional application in sports and fitness ....................17 [3.H2] Professional application in the medical field ...................... 17 [3.H3] h/p/cosmos medical running machines - MDD medical device directive. Safety standards ......18 [3.I] Forbidden use ................................21 [4.] Installation & commissioning ............................22 [4.A] Transport, unpacking and packaging ..........................
  • Page 6 [7.B] Immediate maintenance ............................... 100 [7.C] Regular inspections/examinations ..........................100 [7.C1] Visual inspections ............................100 [7.C2] Protective Earth Resistance R measurement ....................101 file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 6 of 176...
  • Page 7 [8.J2] Devices without UserTerminal ......................... 127 [9.] Technical data ................................128 [9.A] Running machines ................................ 128 [9.B] EMC electromagnetic compatibility. Guidance and manufacturer's declaration ............132 file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 7 of 176...
  • Page 8 [10.E1] Safety precautions and operation ........................141 [10.E2] Operation and adjustment ..........................142 [10.F] Special handrails ................................143 [10.G] h/p/cosmos airwalk se 135 (available as of 10/2008) ....................144 [10.H] Unweighting system h/p/cosmos airwalk ........................145 [10.H1] Vests for subjects for h/p/cosmos airwalk ......................145 [10.I] Wheelchair ramp ................................
  • Page 9 [12.] Disposal ..................................164 [12.A] Disassemble and cut up ............................... 164 [12.B] h/p/cosmos running machine ............................164 [12.C] h/p/cosmos service oil / grease ............................ 164 [12.D] h/p/cosmos running belt ............................... 164 [13.] Contact ..................................165 [13.A] Service department ..............................165 [13.B] Sales department .................................
  • Page 10: [3.] Safety, Warnings, Precautions, Prohibitions

    Valuable articles (like watches, emblazonments, etc.) must be abated before using the device and must also not be in near environment of the device. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 11: [3.B] Exit The Device In Emergency Case

    This instruction manual is part of the device and must always be accessible for every user. Exact observance of the instruction manual is a requirement for the appropriate operation of an h/p/cosmos device. Holding the handrails during exercise may effect the exercise results (e.g. heart rate, ECG, oxygen uptake, etc.). Under normal conditions and for healthy subjects we recommend to hold the handrails only for emergency or when needed for safety or unweighting.
  • Page 12: [3.D] Instructions For Safety And Operation

    Patient security according to VDE 0750 (IEC 601-1) type B [3.D2] If your h/p/cosmos device has a c mark with a 4-digit number (e.g. n) at the identification plate, it is a medical product. At your h/p/cosmos medical product the patient is protected/isolated from the mains in accordance with the safety standard referring to the requirements for leakage current values according to IEC 601- 1 type B.
  • Page 13: [3.D4] Connection Of Units Installed Outside Medically Utilized Locations

    [3.D4] If units installed outside medically utilized locations (e. g. external printer, host computer etc.) are connected to an h/p/cosmos unit installed in a medically utilized location the VDE 0750 regulations must be observed. Connection only via … 1. Optical fibre or optocoupler (4 kV checked and approved) or …...
  • Page 14: [3.D7] Protection Against The Danger Of Electrical Shocks

    (e.g. swimming pool, sauna, etc.) nor in environmental chambers. If not stated otherwise in the delivery information h/p/cosmos devices are designed for operation in normal climatic surroundings (DIN IEC 601-1): + 10 °...
  • Page 15: [3.E] Economic Life-Time

    Safety standards, norms [3.G] All h/p/cosmos running-machines are produced according to strict safety- and quality controls. The running machine must not be used, if the certificates/permissions and the (according to the list of technical specifications) defined safety standards do not correspond with the local and country-specific requirements. The country-specific requirements must be compared before initial operation.
  • Page 16: [3.G1] Vde Norm

    [3.G3] The n mark on the nameplate of the running machine for medical application confirms the compliance to the council directive 93/42/EEC (MDD Medical-Device-Directive). file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 16 of 176...
  • Page 17: [3.G4] Emc Electromagnetic Compatibility

    Children are only allowed to use the running machine under constant supervision of a medical doctor and only when safeguarded by safety harness with fall-stop. Additionally h/p/cosmos suggests the use of adjustable handrails. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com...
  • Page 18: [3.H3] H/P/Cosmos Medical Running Machines - Mdd Medical Device Directive. Safety Standards

    As a manufacturer it is h/p/cosmos’ duty, and as the distributor or end- user/operator of the running machine it is your duty, to minimize those dangers as far as possible.
  • Page 19 To reduce the risk for users, h/p/cosmos running machines have a gap of less than 4 mm and it is marked clearly with additional danger precaution stickers.
  • Page 20 Despite that some of the above mentioned laws and guidelines are only binding within the European Union, the patient’s needs, the risks and the required safety procedures are the same all over the world. We ask all parties involved to help in improving safety. Some examples for safety features at h/p/cosmos devices: Potential isolation Opto coupler board...
  • Page 21: [3.I] Forbidden Use

    A safety arch with chest belt and fall-stop is also obligatory in this case. In environmental conditions, others than specified in the chapter „technical specifications“ and “environmental conditions“, h/p/cosmos devices must not be used (e.g. in wet and humid areas, swimming pools, sauna, environmental chambers, high-pressure-, low-pressure, altitude- and oxygen-chambers, etc.).
  • Page 22: [4.] Installation & Commissioning

    Within Germany mostly all devices are delivered and assembled by h/p/cosmos directly or by an authorised forwarder. If delivered by h/p/cosmos the packaging will be taken back and recycled.
  • Page 23 Transport angle construction running surface 200 ... 300/75 ... 125cm [cos14090] Transport tool for construction size running surface 150/50cm [cos10972] Transport tool for construction size running surfaces 170 and 190/65cm [cos13794] file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 24: [4.A2] Transport With Trolleys

    The levelling sockets and the front wheels of the elevation system may cause a print in the flooring. In case of sensitive flooring please use h/p/cosmos floor mats for protection: Floor protection mat 150/50 for running machines with deck size 150x50 cm [cos14005]...
  • Page 25 (~ 500 kg) / m². At h/p/cosmos gaitway with integrated force plate the transportation locks have to be removed after erection. Drive elevation up to max of 25 %. Loosen the four M8 screws, indicated with the red arrows at the underside of the alu- force plates and remove them.
  • Page 26: [4.C] Electrical Installation

    To start again you have to switch-on the running machine at the main „ON“ switch and than press START at the keyboard. Installation of any electrical device and h/p/cosmos running-machines must only be carried out at a voltage power connection with ground wire (earthing) including leakage-current protection-switch (interrupter) and according to VDE 0100 or/and the currently valid regulations and directives.
  • Page 27: [4.C1] Name Plate

    Name plate [4.C1] Name plate examples sports device model h/p/cosmos quasar / medical device h/p/cosmos saturn 300/125r For full details please refer to the chapter „technical data“ in this manual. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc ©...
  • Page 28: [4.C2] Electric Safety Measurements And „First Measured Values

    One copy of this protocol [cos11690xx] remains at the owner’s manual and the original of the protocol with the „first measured values“ shall be sent to the manufacturer h/p/cosmos. Picture: Example for electric safety testing device based on IEC 601-1 Potential equalization [4.C3]...
  • Page 29: [4.C4] Plug Assignment At The Userterminal

    If the UserTerminal was disassembled during transport please connect the cables according to following illustration: Devices with MCU5 control unit (as of manufacturing date 12/2007) file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 29 of 176...
  • Page 30 & commissioning Devices with MCU4 control unit (until manufacturing date 12/2007) file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 30 of 176...
  • Page 31 & commissioning For devices with MCU4 control unit (until manufacturing date 12/2007) and reverse belt rotation file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 31 of 176...
  • Page 32 Above: Drawing cable connection for ON/OFF button and emergency stop in the UserTerminal Right hand side: Ground connection at the UserTerminal Note: GND / GND = ground file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 32 of 176...
  • Page 33: [4.D] Starting The Running Machines

    The indicator light within the key is glowing (if the indicator does not flash up, please check the power supply, the expulsion fuse and the Emergency-stop). file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 34: [4.D3] Switching The Device Off

    Devices for Sports and Fitness manufacturing before 12/2007 The machine can be switched off directly with the explusion fuse at the FrontTerminal (frontal section below the hood). file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 35: [4.E] Emergency-Stop / Emergency-Off

    „Switching the device off“. Use the emergency-stop only if in danger. The emergency-stop is not to be used as a normal stop-key. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 35 of 176...
  • Page 36: [4.F] Installation, Overview, Checklist

    The authorized technician (distributor or service partner) has to check whether the installation of the device has been performed properly, before the customer is introduced into the operation of the h/p/cosmos device. For detailed information and instructions for installation and commissioning please refer to all respective individual chapters in this manual.
  • Page 37 For details please refer to chapter „maintenance / inspections“. One copy of this protocol [cos11690xx] remains at the owner’s manual and the original with the „first measured values“ shall be sent to h/p/cosmos. The potential equalization cable has to be ‰...
  • Page 38: [5.] Operation

    To control via USB interface the processor must be a Pentium 1.8 GHz or higher. To use all the functions described below and for maintenance and service we recommend the PC software h/p/cosmos para control ®...
  • Page 39: [5.A1] The Keyboard

    (LED) in addition, which supply information about mode, measuring unit and so on. Flashing displays indicate: select option (LED ~) alterable parameter (LCD) interference / error file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 39 of 176...
  • Page 40: [5.A3] The Display (Standard Configuration)

    M = male F = female ‘ ° year Step Weight Weight Height of subject H ..LED on / LED off file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 40 of 176...
  • Page 41: [5.B] Mode Of Operation

    7 different acceleration levels and deceleration levels are available for all modes and for remote control via interface and h/p/cosmos coscom protocol. Max. acceleration level and minimum acceleration level see chapter: User options / optional functions. The following diagram shows the acceleration levels at a running machine with maximum speed of 40km/h.
  • Page 42: [5.B3] Manual Mode

    Alteration of elevation Elevation is being increased / reduced (0 ... max.) as long as the key get pressed. press and hold file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 42 of 176...
  • Page 43: [5.B4] Automatic Mode

    Test No 21 ... 28 are user defined (free programmable Profiles). For a better and easier documentation we recommend to use the serial printer interface or to connect an external PC in order to use the h/p/cosmos para graphics ®...
  • Page 44 Herewith you can create more variations out of the 6 standard Profiles. Continue with A) [05] Stop running-belt Running belt stops. (Deceleration time can be adjusted in the optional functions) file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 44 of 176...
  • Page 45: [5.B6] Possibilities Of Interfering Into The Profile Mode Manually

    For a better documentation we recommend to use a printer linked to the serial interface or/and to use an external PC with the ® Software h/p/cosmos para graphics file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 46: [5.B7] Profile Outline

    Endurance interval standard Warming up High 1 Low 1 High 2 Low 2 High 3 Low 3 High 4 Low 4 25 min file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 46 of 176...
  • Page 47 High 3 10.0 Low 3 High 4 10.0 Low 4 High 5 10.0 Low 5 High 6 10.0 Low 6 25 min file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 47 of 176...
  • Page 48 Low 3 10.1 High 4 13.0 Low 4 10.1 High 5 11.5 Low 5 10.1 High 6 11.5 Low 6 10.1 25 min file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 48 of 176...
  • Page 49: [5.B8] Cardio Mode - General Notes

    Place the transmitter so that it is right below the pectoral muscle (chest), as is shown in the illustration above. For ca. 95 ... 98 % of the subjects the "normal" placement of the transmitter belt is recommended. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 50 1.0 km/h 1.0 % 10 Seconds 30.1 ... 50 1.5 km/h 1.2 % 8 Seconds > 50 2.0 km/h 1.6 % 7 Seconds file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 50 of 176...
  • Page 51: [5.B10] Cardio Mode - Operation

    35 (for the subject's age) years is glowing [05] Select personal age indicates flashing: 0 ... 100(for the age), from Firmware V3.02.4: 18 ... 100 file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 51 of 176...
  • Page 52 For a better documentation we recommend to use a printer linked to the serial interface RS232 or/and to use an external PC ® with the Software h/p/cosmos para graphics file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 53: [5.B11] Possibilities Of Interfering With The Cardio Mode Manually

    For example to start manual mode and simultaneous for a "cool-down" period without stop of the belt. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 53 of 176...
  • Page 54: [5.B12] Test Mode And Free Program Profiles - General Notes

    Acceleration level: 4 (adjustable from 1 to 5) Break time: 30 sec. (can be changed) STOP must be activated manually by the medical doctor. Continuation next page ... file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 54 of 176...
  • Page 55 Circuit (lap length): 200m (can be changed) Increment: 0.5 km/h (can be changed) STOP must be activated manually by the medical doctor when the subject is fully exhausted. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 55 of 176...
  • Page 56 0.32 km/h every minute STOP must be activated manually by the medical doctor when the subject is fully exhausted file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 57 (not for all models available) maximum speed of the treadmill. Time for reaching target speed in seconds: Standard: 10 seconds; adjustable from 0 to 99 seconds file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 57 of 176...
  • Page 58 15.5 km/h 1:30 min 0.0 km/h 600 m 16.5 km/h 1:30 min 0.0 km/h 600 m 17.5 km/h 1:30 min 0.0 km/h file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 58 of 176...
  • Page 59 19.0 km/h 1:00 min 0.0 km/h 500 m 17.0 km/h 1:15 min 0.0 km/h 600 m 15.0 km/h 1:30 min 0.0 km/h file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 59 of 176...
  • Page 60 20.0 km/h 0:45 min 0.0 km/h 300 m 20,0 km/h 0:45 min 0,0 km/h 300 m 20,0 km/h 0:45 min 0,0 km/h file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 60 of 176...
  • Page 61 11.0 km/h 10 % 1:00 min 12.0 km/h 10 % 2:00 min 12.0 km/h 11 % 2:00 min 12.0 km/h 12 % file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 61 of 176...
  • Page 62 8.0 km/h 8.0 km/h 12 % 8.0 km/h 15 % 8.0 km/h 18 % 8.0 km/h 21 % 8.0 km/h 24 % file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 62 of 176...
  • Page 63 0.0 km/h 3:00 min 27.0 km/h 0:30 min 0.0 km/h 3:00 min 28.8 km/h 0:30 min 0.0 km/h 3:00 min 30.6 km/h file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 63 of 176...
  • Page 64 0.0 km/h 18 % 3:00 min 14.4 km/h 18 % 0:30 min 0.0 km/h 20 % 3:00 min 14.4 km/h 20 % file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 64 of 176...
  • Page 65 14.3 km/h 2:30 min 14.3 km/h 2:20 min 11.2 km/h 0:10 min 13.4 km/h 1:00 min 19.3 km/h 1:00 min 15.0 km/h file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 65 of 176...
  • Page 66 For a better documentation we recommend to use a printer linked to the serial interface RS232 or/and to use an external PC with the Software h/p/cosmos para graphics ® file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 67: [5.B14] Test Mode - Operation

    80% of their max. heart rate ( 220 – age). The test duration and heart rate are measured immediately after finishing the 2 km distance. At h/p/cosmos devices the heart rate is measured every 500m due to higher accuracy.
  • Page 68 A serial printer or a PCL-printer with parallel/centronics plug und converter [cos10056] can be connected directly to the h/p/cosmos running machine. Following data can be printed after the UKK walk test even without using any PC: UKK fitness index, date, time, test duriation, distance, elevation, heart rate, age, sex, body-mass-index (BMI).
  • Page 69: [5.B16] Programing Example: Ukk Walk Test

    "P 0" flashing and at the same time an acoustic signal appears, the running machine cannot receive the heart rate of the subject. Check chest belt system. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 69 of 176...
  • Page 70: [5.B17] Programming-Example: Free Definable Profile

    For a better documentation we recommend to use a test result (Fitness index and printer linked to the serial interface RS232 or/and to use time) an external PC with the Software h/p/cosmos para ® graphics Programming-example: free definable profile [5.B17] Programming and correction of a free programmed test is possible in test mode „...
  • Page 71 [16] Select time 2 minutes [17] Confirm time indicates time (seconds): Value "2:00" is flashing [18] Select time 30 seconds file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 71 of 176...
  • Page 72 [37] Confirm acceleration level indicates speed: Value "0.0" is flashing indicates program step:" St. 5 " [38] Select der Speed 6.0 km/h file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 72 of 176...
  • Page 73 For a better documentation we recommend to use a printer linked to the serial interface RS 232 or/and to use an external PC ® with the Software h/p/cosmos para graphics file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 74: [5.B18] Possibilities Of Interfering In Test Mode Manually

    For a better documentation we recommend to use a printer linked to the serial interface RS 232 or/and to use an external PC ® with the Software h/p/cosmos para graphics file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 75: [6.] Optional Settings

    Optional settings serve for example as an acknowledgement of error notes on the display, or for the standard setting of the device: selection of RS232 interface protocol, etc. Remark for devices without UserTerminal: For optional settings on devices without UserTerminal an external UserTerminal or a connected PC with the software h/p/cosmos para control ® is required.
  • Page 76: [6.A2] List Of User Options / Optional Functions

    List of user options / optional functions [6.A2] For devices without UserTerminal: An external UserTerminal or PC software h/p/cosmos para control ® is required to control the running machine via RS232 interface. Option Description Comment / Display [6.A2]...
  • Page 77 10 ... 250 (estimated weight) weight blinking The personal body weight is necessary for a more correct calculation (estimation) of the power and energy consumption. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 77 of 176...
  • Page 78 (can also be set with UP and DOWN) (further settings in user OP23 and administrator OP16 are necessary) file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 79 Various Ergospirometry OFF = RS232 not active / no protocol / interface deactivated systems support the h/p/cosmos coscom 1 = h/p/cosmos coscom v1, v2, v3 with Baudrate 9600 bps protocol. Individual adaptation ( standard setting COM 1 and COM 2) protocol request.
  • Page 80 NOT valid for control and operation via RS232-interface. In this case the acceleration and deceleration level is set in option no. 29 resp. set in the corresponding command of the h/p/cosmos coscom protocol. § OP28 Maximum acceleration and deceleration blinking, reports the max.
  • Page 81 For a correct printout the connected printer must be compatible with PCL printer language. For special characters the ISO 8859-1 (Latin-1) font is used. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 81 of 176...
  • Page 82: [6.A3] Standard Settings For The User Options

    0 = no single values, 1 ... 100 OP 53 Language settings for printer protocol English English, German, French, Spanish Portuguese, Hungarian file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 82 of 176...
  • Page 83: [6.B] Administrator Options

    Administrator options [6.B] The administrator options are only accessible by h/p/cosmos staff and authorised service engineers. The access is only possible with a special code which is not depicted here. Changing an administrator option might cause serious problems if you are not familiar with all the details. Therefore the h/p/cosmos service has to be contacted before doing any changes in the administrator options.
  • Page 84 According to the selected device type (in OPTION 03) the standard maximum speed will be indicated in the SPEED Display. Example: h/p/cosmos mercury 4.0 = 22.0 km/h; h-p-cosmos discovery 4.0 = 40 m/min For safety purposes (e.g. for beginners) the max. speed of every treadmill model can be limited.
  • Page 85 OFF = no comparison 6 = 6 % deviation is allowed 8 = 8 % deviation is allowed 10 = 10 % deviation is allowed file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 85 of 176...
  • Page 86 To activate the motor break it is necessary to additionally change some parameters at the frequency inverter. Ask the service department of h/p/cosmos sports & medical gmbh for detailed instruction. Attention! If the device is switched off or disconnected from...
  • Page 87 If the speed measurement is switched off in OP11, then OP34 will only report internal program absolutes. In the other case following values are stored: Running machine series h/p/cosmos mercury with special speed 10 km/h: Speed Calibration Value: 8.490 Inverter Frequency: 80.2 Hz...
  • Page 88 [6.B1] special speed 45 km/h: Speed Calibration Value: 2.874 Inverter Frequency: 125 Hz Running machine series h/p/cosmos pulsar 3p with 40 km/h: Speed Calibration Value: 2.874 Inverter Frequency: 110 Hz Running machine series h/p/cosmos pulsar 3p with special speed 45 km/h: Speed Calibration Value: 2.874...
  • Page 89 Appropriate protocols and inspection instructions are available at h/p/cosmos service. To provide for this an error message "E 02" "HELP" for the TSC-service interval will appear in the display after expiration of a time period of 12 month.
  • Page 90 After a service with lubricating the treadmill and performing all maintenance work the oil and service interval can be set back with option number OP47. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 90 of 176...
  • Page 91 10 volt. Note down the voltage at the service report! (not possible with digital control via RS485) Read off the speed and write down the value at the h/p/cosmos service report: OP 48: _____ km/h Stop the running belt with the STOP key.
  • Page 92 Note: At each emergency-stop the number of timeout errors is increased compulsorily by at least one numerator, because the transmission line to the FI is being interrupted by hardware. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 93 ( models h/p/cosmos venus since 1997) 4 = elevation control: linear motor for 0 - 24% elevation, increment sensor, lift range 240 mm (h/p/cosmos mercury models since 1997) 5 = elevation control: linear motor for 0 - 28% elevation, increment sensor, lift range 300 mm (h/p/cosmos quasar 4.0...
  • Page 94 Total distance (km) report: total distance in km reports km Difference to user option 02: the displayed value can also be changed. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 94 of 176...
  • Page 95 *Note: It is not allowed to change the total time of operation or the total distance of the running-machine to a value which does not match to the real value of the device. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 96: [6.B2] Standard Settings Of Administrator Options

    Distance between rungs in 0.1 cm ergometer) OP 34 Manual Speed Calibration (depending on the device type; Range from: 0 to 65535 OP 03) file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 96 of 176...
  • Page 97 Test-Profile 99 for endurance testing in 0 = Test 99 de-activated 0 = Testprofile 99 de-activated the factory / service 1 = Testprofile 99 activated file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 97 of 176...
  • Page 98: [6.B3] List Of Running Machines Types

    190 / 65 -5.0 km/h 45.0 km/h 25.0 % 2874 46.0 km/h For any questions about the correct device type, contact the h/p/cosmos service before doing any changes. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 99: [7.] Maintenance And Safety Inspections

    Preventive maintenance [7.A] The h/p/cosmos authorised service engineers are happy to help you in the case of occurring problems. A preventive maintenance can avoid problems in the future and is indispensable for the safety of such technical devices. Therefore ask for an annual preventive maintenance contract, which is highly recommended by the manufacturer, from our service department.
  • Page 100: [7.B] Immediate Maintenance

    The main inspection sticker on the device (e.g. running machine) certifies also the inspection of the optional equipment and the accessories. However, inspection intervals for optional equipment and accessories (e.g. rope of h/p/cosmos airwalk unweighting system, chest belt for safety harness, compressors, etc.) can deviate significantly from inspection intervals of the main device.
  • Page 101: [7.C2] Protective Earth Resistance R

    The measuring is to be performed with measuring devices for the isolation-resistance measurement according to VDE 0701/0702 (sports and fitness machines) or VDE 0751/IEC 601-1 (medical devices). file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 101 of 176...
  • Page 102: [7.C4] Equivalent (Alternative) Leakage Current I

    120 volts on the metal housing and frame parts. Do not touch the device under test during this measurement! file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 102 of 176...
  • Page 103: [7.C6] Electric Safety Tester And Measurements

    Due to the test of the RCD switch it possibly comes, depending on the circuit of the building electricity, to a switch- off of the complete or a part of the power supply of the building. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 104: [7.D] Lubrication Of The Running Belt/Running Surface

    An h/p/cosmos authorized technical service engineer will then advise what corrective action needs to be taken. Only use original h/p/cosmos special oil. The use of other oils or the ignoring of the regular lubrication checks can lead to damage of the running belt, running deck or the lubrication system and a reduction of warranty liability.
  • Page 105 Special oil 0.25 l - bottle for sliding plate with manual lubrication [cos000200008001] Syringe 10 ml for lubrication of sliding plate [cos12181] file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 105 of 176...
  • Page 106: [7.D2] Lubricant Test

    The tissue needs to be pulled through the gap between running belt and running surface in a defined lenght in order to absorb a certain quantity of lubricant. Based on previous experience h/p/cosmos is able to evaluate the quantity of the oil film by measuring the weight difference. However, it needs to be considered that this test can only find out approximate values and trends and can never replace the direct survey by the authorized h/p/cosmos technician in the prescribet time intervals.
  • Page 107: [7.D3] Devices Without Userterminal And Without Automatic Oil-Pump

    Please contact h/p/cosmos to receive the special oil. The running belt should be lubricated after 1000 km (special devices might have different intervals) at the latest or/and after hearing dry grinding noises during operation. After lubrication the oil message has to be terminated with "OPTION 01".
  • Page 108: [7.D4] Devices With Userterminal & Automatic Oil-Pump (Models "R" For Cycle & Wheelchair)

    Thus at those models a lubrication test (tissue-test) according the instruction (available from h/p/cosmos) must be performed in the course of the obligatory yearly maintenance. The test must be sent back to h/p/cosmos afterwards for evaluation purposes.
  • Page 109 The device does not have a sensor, the oil-message does not extinguish automatically. After checking the oil-level, the message has to be quit with „OPTION 01“. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 110: [7.D5] Set Back Of Oil Message Mcu 4 Without Userterminal

    Special oil for sliding plate with automatic lubrication/0.25l-bottle [cos14007] Special oil for sliding plate with automatic lubrication/0.50l-bottle [cos13438] Set back of oil message MCU 4 without UserTerminal [7.D5] An external UserTerminal or the PC-software h/p/cosmos para control ® is required for this. Further instructions see "Devices with UserTerminal”.
  • Page 111: [7.E] Control And Tightening Of The Running Belt

    [2]. All bigger models are tightened at the front drive shaft [5]. Mark of 1000 mm [1] applied when belt [4] absolutely loose. Tighten belt, until mark expanded up to between 1004 and 1005 mm (= 0.4 to 0.5 %). file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 112: [7.F] Adjustment (Centering) Of The Running Belt

    As long as the running belt returns to the centre at a speed of 12 km/h it is not necessary to readjust. The running belt remains in the adjusted position for a period of months if it has been done correctly. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 113: [7.G] Control And Tightening Of The Driving Belt

    The tension at the bottom trumm (see picture) must be between 98 Hz and 103 Hz (frequency at oscillation). The noise (at higher speeds) and the straight position of the driving belt need to be considered. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 114 < value 98: belt tension need correction. frequency > value 102: belt tension need correction. After changing the tension of the drive belt new check is necessary. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 115: [7.G2] Driving Belt With Timing-Belt System

    At devices with external control unit the internal space of the control unit must be cleaned as well. The cleaning of the surfaces of the treadmill can be done with a light moistened cloth. For disinfection h/p/cosmos recommends Bacillol plus [cos12179].
  • Page 116: [7.J] Cleansing And Adjustment Of The Speed-Sensor/Light-Barrier

    Right hand side: The distance [1] between induction sensors [2] to the cogwheel [3] must not be bigger than 0.8 mm. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 116 of 176...
  • Page 117: [7.K] Cleansing And Adjustment Of The Light-Barrier At Belt-Re-Entry-Zones

    Light barrier must not be exposed to dazzling flash light of cameras. They might turn off and stop the running belt abruptly. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 118: [8.] Trouble Shooting

    Expulsion fuse / ON-OFF button 2-pole C16A Expulsion fuse, device fuse 3-pole C16A Secondary fuse isolation transformer 1-pole B16A Secondary fuse isolation transformer 3-pole C16A file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 118 of 176...
  • Page 119: [8.D] Interference Factor

    Pay special attention to the EMC (electro magnetic compatibility) data and manufacturer’s declaration in the chapter „technical data / EMC“ of this manual. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 120: [8.E] Voltage At The Device Housing / Electric Shock

    Electric devices, electric motors, transformer High-voltage transmission lines, also from trains Strong fluorescent tubes near by Central heating radiators Other electric devices file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 120 of 176...
  • Page 121: [8.F1] Troubleshooting Heart Rate Measurement System Polar

    In rare cases, after several years of use, malfunctions of the control unit are possible because of worn battery power. In this case contact the service department to change the battery of the control unit. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 122: [8.I] Error Messages / Error Codes

    Every 12 months a electric saftey inspection is due. See chapter maintenance in this manual. Contact authorized service engineer Set back error message (option 01) file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 122 of 176...
  • Page 123 Attention: Dangerous voltage and danger of being hurt when the device is open. Do not touch the parts inside the device file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 123 of 176...
  • Page 124 (instantaneous value) is at least the in Error search see E30. administrator-option 12 set percentage LOWER than the calculated value (debit- value) file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 124 of 176...
  • Page 125 At MCU5 control electronic (as of manufacturing date 12/2007) this error exclusively shows a defect of the option memory (FRAM). In this case, please contact h/p/cosmos and request a service technician. Optional setup restores to default factory setting and device...
  • Page 126 Running machine is still functioning (except chip card function) Test ident on the chip-card not accepted False chip-card in the chip-card-drive Insert the correct chip-card file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 126 of 176...
  • Page 127: [8.I2] Devices Without Userterminal

    "5 times LONG (code for "0")" and 1 time SHORT + 4 times LONG (code for "1") will be repeated 3 times. Error Code list see: Devices with UserTerminal. The error messages have to be terminated with "OPTION 01". An external UserTerminal or a PC software h/p/cosmos para control ®...
  • Page 128: [9.] Technical Data

    Running machines [9.A] UserTerminal 6 LCD displays / 6 keys / display of mode and unit with LED. „lt-models“ and „h/p/cosmos 150/50 locomotion E med“ (Display & Keyboard) have no UserTerminal (no display, no keyboard). Control only via interface. Power supply...
  • Page 129 When using a front-bar handrail (crossbar), the speed is limited to 5 km/h for safety reasons. Data of weight and measurements can deviate. Ask for further details and optional equipment or visit www.h-p-cosmos.com. Subject to technical alterations without prior notice. E & EO. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 130 [e] 3000 x 1500 [f] 3000 x 2000 3000 [r] = suitable for bicycle and wheel [c] 2500 x 1250 1000 chair application file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 130 of 176...
  • Page 131 (TO = 15 %) converts to approx. 5 full elevation cycles. Overload can result in temporary tripping of the fuse, but can be used again after short cool down period. Treadmills of the h/p/cosmos saturn series built approx. before January 2007 have a maximum elevation of 25%.
  • Page 132: [9.B] Emc Electromagnetic Compatibility. Guidance And Manufacturer's Declaration

    Please pay special attention also to the other EMC related chapters of this manual: Chapter: Safety, Installation, Operation, POLAR heart rate monitor: EMC Chapter: Error, Malfunction, possible interference file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 133 NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 134: [9.C] Compatibility Rs232 Interface / Usb Converter

    IEC 601-1: 6.8.2.c, 19.2.b, 19.2.c). More recent computers will have only an USB interface instead of the RS232 interface. For that case an „USB to RS232 interface-adapter-cable“ is available at h/p/cosmos under item no. cos12769. To control via USB interface you need a processor Pentium 1.8 GHz or higher.
  • Page 135: [10.] Accessories And Options

    The h/p/cosmos arm supports (patent no.: DE 199 16 508 A1) are available for the h/p/cosmos running machines with running deck size 150/50, 170/65 and 190/65 cm but not for running machines with adjustbale handrails.
  • Page 136: [10.A2] Reproducibility Of Adjustments

    The additional stop-button for the case of an emergency is accessible at any time with the thumb. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 137: [10.C] Handrails Adjustable With Gear Tooth Locking Elements

    6 keys incl. 2m spiral cord cos10106 mount for additional keyboard on arm support cos10111 h/p/cosmos additional stop button (red button on top of handgrip) for arm support right cos10107 h/p/cosmos additional stop button (red button on top of handgrip) for arm support left cos10108 mount for additional stop button on handrail with clamp for circular tube 60mm Œ...
  • Page 138: [10.C1] Danger Precaution And Operation

    While adjusting make sure that you do not pen in yourself or any other person at the danger spots (squeezing and jamming spots). Using the h/p/cosmos arm support with the adjustable handrails is not possible. Reproducibility of adjustments [10.C2]...
  • Page 139: [10.D] Handrails Adjustable. Parallel Bars With Gas Struts And Locking Lever

    Handrails adjustable. Parallel bars with gas struts and locking lever [10.D] The bar handrails adjustable in height and width are available for the h/p/cosmos running machine of the “locomotion series” exclusively. The individually adjustable handrails offer utmost safety at best possible freedom of movement. Well suited for therapy with insecure and elderly patients as well as for therapy with children.
  • Page 140: [10.D2] Adjustment Of The Bar Handrails

    If turing the UserTerminal to outside position, then at least 1 emergency-stop-button has to remain in reach of the subject at any time. The use of the h/p/cosmos arm supports is not possible with the adjustable bar handrails. Adjustment of the bar handrails [10.D2]...
  • Page 141: [10.D3] Reproducibility Of Adjustments

    Open and overhanging clamp handles are a source of danger as well. Therefore pay attention to always lock the fixation screws before using the seat and foot support. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 142: [10.E2] Operation And Adjustment

    Release the fixation screw underneath the seat to adjust the optimal seat position. [03] Fix the adjusted seat and foot support position by tightening the corresponding fixation screws file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 142 of 176...
  • Page 143: [10.F] Special Handrails

    2 pillars handrail detachable / separable Details and order numbers are available at the manufacturer h/p/cosmos or at your local authorized distributor. The crossbar always needs to be positioned in that way that at least 2/3 of the running surface behind the crossbar is free for the user.
  • Page 144: [10.G] H/P/Cosmos Airwalk Se 135 (Available As Of 10/2008)

    135 (available as of 10/2008) [10.G] The „h/p/cosmos airwalk se 135“ is a user friendly and novel dynamic unweighting system with central point suspension for manual locomotion therapy. It improves the manual training due to constant un-weighting of the patient in the vertical movement area.
  • Page 145: [10.H] Unweighting System H/P/Cosmos Airwalk

    It is possible to use the h/p/cosmos airwalk with the running machine series with track size 150/50cm or 170/65cm or 190/65cm, and as well with most running machines produced by other manufacturers.
  • Page 146: [10.I] Wheelchair Ramp

    [10.J] With the help of the h/p/cosmos wheel chair stabilizer it is easy to keep wheel chairs with 4 or 3 wheels safely in lane. The guide rail is fixed between the two pillars of the right-hand side handrail.
  • Page 147: [10.K] Safety Arch With Chest Belt And Harness

    The ceiling height should be at least 2.46m / 97.6 inches (0 % elevation) rsp. 2.57 / 101.6 inches (24 %) if used with h/p/cosmos mercury and 2.51 / 96.5 inches (0 %) rsp. 2.68 m / 105.5 inches (max. elevation) if used with running machines h/p/cosmos quasar or h/p/cosmos pulsar.
  • Page 148: [10.L] Running Belt Rotation Reversible For Downhill Walk

    Once the belt is readjusted, STOP the belt and operate the machine with the subject on the belt. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 149: [10.L3] Change From Reverse To Forward Rotation

    Bottle holder [10.M] The bottle holder is available for all h/p/cosmos running machines and can be easily fixed with a clamp on the handrail. The position of the bottle holder must not be at the rear end of the handrail due to this end must be reachable for the subject.
  • Page 150: [10.P] Safety Multiple Socket

    Running-Machine from another controlling device (ECG. o.a.) or with the appropriate Software from a PC, via interface. Standard for all devices is ONE serial interface COM 1. Optionally there are further serial interfaces COM 2, COM3 and COM4 available. For further information please contact your local dealer or h/p/cosmos. The interface protocol h/p/cosmos coscom ©...
  • Page 151: [10.Q1] Interface Cable Rs232 For Connection To Pc

    OXYCON Alpha / Delta / Champion / Pro: Connect the running machine interface with an available serial interface (COM1 ... COM4) at the PC of the OXYCON. Do not use the female connector at the OXYCON with the letters "treadmill / running machine". Important: From January 2000 use h/p/cosmos coscom ©...
  • Page 152: [10.R] Printer Protocol

    RS232 of the running machine. Attention: For a printer with a parallel interface you will need a commercial interface- converter, available in every computer-store, at your local dealer or from the manufacturer (h/p/cosmos order no. [cos10056]). If Option 20: 3 is chosen (printer protocol see list of options), following data will be printed out: Interface converter for printer [cos10056] file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc...
  • Page 153: [10.S] Polar Heart Rate Measurement System

    The transmitter radius amounts to approx. 80 to max. 120 cm. If you run several Running-Machines or other training devices on the same heart rate measurement system, you should keep a gap of at least 100 cm between the devices to exclude interference. file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008...
  • Page 154: [10.S4] Battery Of The Transmitter

    3.0. In addition to the pure remote control function of h/p/cosmos treadmill-ergometers over the pc the software has integrated now a lot of additional functions such as an option setting configuration tool with integrated storage function, firmware update over flash eprom, quick-stop-key, cool-down-key, pause-key, target speed settings, target elevation settings, stop-count-down, display reset, etc.
  • Page 155 & info DVD [cos10067] which is delivered together with every h/p/cosmos treadmill-ergometer. Alternatively the software can be downloaded at www.h-p-cosmos.com/en/software. At aforementioned link also a manual can be found in which all functions of the new para control 4.0 are described in detail.
  • Page 156: [10.U] Pc Software H/P/Cosmos Para Graphics

    The data can be converted by the software and be taken over and evaluated e.g. by EXCEL, or h/p/cosmos para analysis software. A take over and processing of the data within a spreadsheet (EXCEL, etc.) or an editor is also possible with the help of the h/p/cosmos para graphics ®...
  • Page 157: [10.V] Pc Software H/P/Cosmos Para Analysis

    The evaluation of heart rate and lactate curves after graded test is possible on the basis of individual selected threshold models in graphics and tables. It is possible to enter the test data in h/h/p/cosmos para analysis ®...
  • Page 158: [10.W]Pc Software H/P/Cosmos Para Motion

    & options PC Software h/p/cosmos para motion [10.W] The h/p/cosmos para motion is a software for recording and evaluation of video analysis with individual report for printout, incl. control functions of h/p/cosmos running machines. Basic functions and features Digital, software-based video recordings with treadmill control for all h/p/cosmos treadmills parallel to recording with feedback.
  • Page 159: [11.] Certificates

    Certificates [11.] Certificate of the TSA (TÜV) according to ISO 9001-2000 [11.A] file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 159 of 176...
  • Page 160: [11.B] Certificate Of The Tsa (Tüv) According To En Iso 13485-2003

    Certificate of the TSA (TÜV) according to EN ISO 13485-2003 [11.B] file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 160 of 176...
  • Page 161: [11.C] Ec Certificate Of The Tsa (Tüv)

    EC Certificate of the TSA (TÜV) [11.C] file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 161 of 176...
  • Page 162: [11.D] Certificate Of Compliance For Sports And Fitness Devices

    This certificate of compliance covers all running machine models which are listed above and which are produced by h/p/cosmos on and from November 24, 2006. The validity of this certificate of compliance expires on the release date of a certificate of compliance with a later issue date, which may be necessary due to technical modifications or due to changes of standards, guidelines and directives.
  • Page 163: [11.E] Certificate Of Compliance Medical Devices

    This certificate of compliance covers all running machine models which are listed above and which are produced by h/p/cosmos on and from November 24, 2006. The validity of this certificate of compliance expires on the release date of a certificate of compliance with a later issue date, which may be necessary due to technical modifications or due to changes of standards, guidelines and directives.
  • Page 164: [12.] Disposal

    Disposal [12.] By request and at the expense of the client h/p/cosmos might take over the disposal of old devices and devices not longer functioning. Please contact service@h-p-cosmos.com for a detailed offer. Note the information for possible disposal of the running machine parts or components through the client or a subcontractor.
  • Page 165: [13.] Contact

    & production Am Sportplatz 8 DE 83365 Nussdorf-Traunstein Building 2 (picture below) h/p/cosmos sales & service Feldschneiderweg 5 DE 83365 Nussdorf-Traunstein file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 165 of 176...
  • Page 166: [14.] Appendix - Instruction And Commissioning

    After the instruction is completed the instruction protocol is to be signed by the h/p/cosmos technician and all trained persons and sent back, together with the signed delivery note and the registration form, to h/p/cosmos.
  • Page 167: [14.B] Instruction Into Functions

    ‰ accomplished [05] Operation of running machine via program mode. Refer to the list of programs in the instruction manual. ‰ accomplished file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 167 of 176...
  • Page 168 Explanation of test-mode and the integrated test-programs, inform about interface and compatibility list. In medical field potential isolation for any interface linkage is obligatory! Inform about the h/p/cosmos software programs h/p/cosmos para control, h/p/cosmos para graphics, h/p/cosmos para analysis and h/p/cosmos para motion for documentation and evaluation of data.
  • Page 169: [14.C] Instruction Into Maintenance Works

    [04] Lubrication of running belt when "OIL"-message (quantity, intervals according to instruction manual, spread the oil by "Duck-walking"). Use only original h/p/cosmos lubricant authorized for this model of running machine. Observe demand for additional lubrication based on manual. After running belt lubrication the position of the running belt must be checked once more and be adjusted if necessary.
  • Page 170: [14.D] Advice And Support Documents

    [14.D] [01] Hand over and explain delivery papers (folder). Fill out registration form and send it to h/p/cosmos sales. Let the customer sign the delivery note and instruction protocol and send it back to h/p/cosmos sales immediately. Ask for brochure of customer and send it to the sales department at h/p/cosmos.
  • Page 171: [14.E] Confirmation Of Commissioning And Introduction / Instruction

    Please fill out the instruction protocol and send back to h/p/cosmos via Fax to +49 / 86 69 / 86 42 49, via email to sales@h-p-cosmos.com or via post h/p/cosmos sports &...
  • Page 172: [14.F] Service Report - Cos15531

    Service report – cos15531 [14.F] file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 172 of 176...
  • Page 173: [14.G] Control Protocol - Cos15533

    Control protocol – cos15533 [14.G] file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 173 of 176...
  • Page 174: [14.H] Wiring Diagram Load Circuit Quasar Med 5.0 / Pulsar 5.0

    Wiring diagram load circuit quasar med 5.0 / pulsar 5.0 [14.H] file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 174 of 176...
  • Page 175: [14.I] Wiring Diagram Control Circuit Quasar Med 5.0 / Pulsar

    Wiring diagram control circuit quasar med 5.0 / pulsar 5.0 – page 1 [14.I] file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 175 of 176...
  • Page 176: [14.J] Wiring Diagram Control Circuit Quasar Med 5.0 / Pulsar

    Wiring diagram control circuit quasar med 5.0 / pulsar 5.0 – page 2 [14.J] file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc © 2008 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 01.09.2008 printed 08.10.2008 page: 176 of 176...