Operating instructions and service manual
h/p/cosmos running-machine series:
150/50 (mercury)
N
170-190/65 (quasar / pulsar)
N
200-450/75-300 (venus / saturn)
N
running machine model name
h/p/cosmos mercury
h/p/cosmos mercury med
h/p/cosmos quasar
h/p/cosmos quasar med
h/p/cosmos pulsar
h/p/cosmos pulsar 3p
h/p/cosmos stratos
h/p/cosmos stratos med
h/p/cosmos stellar
h/p/cosmos stellar med
incl. lt-models
file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc
running machine
running machine model name
h/p/cosmos locomotion 150/50 E med
h/p/cosmos locomotion 150/50 DE med
h/p/cosmos Kistler Gaitway II F
h/p/cosmos Kistler Gaitway II S
h/p/cosmos venus - all sizes
h/p/cosmos saturn - all sizes
manual-version
MCU5-v1.06
Revision 20120210
manual order-no.:
[cos14310m5-v1.06hpc-en]
h/p/cosmos sports & medical gmbh
phone +49 86 69 86 42 0
fax +49 86 69 86 42 49
© 2012 h/p/cosmos sports & medical gmbh
manual
Am Sportplatz 8
DE 83365 Nussdorf-Traunstein / Germany
email@h-p-cosmos.com
author: fh
created 15.02.2012
printed 15.02.2012
development, production, sales & service
h/p/cosmos sports & medical gmbh
Am Sportplatz 8
DE 83365 Nussdorf-Traunstein
Germany
phone +49 86 69 86 42 0
fax +49 86 69 86 42 49
service@h-p-cosmos.com
www.h-p-cosmos.com
www.h-p-cosmos.com
page: 1 of 213

Advertisement

Table of Contents
loading

Summary of Contents for h/p/cosmos mercury

  • Page 1 DE 83365 Nussdorf-Traunstein / Germany phone +49 86 69 86 42 0 fax +49 86 69 86 42 49 email@h-p-cosmos.com www.h-p-cosmos.com file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh created 15.02.2012 printed 15.02.2012 page: 1 of 213...
  • Page 2 © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 2 of 213...
  • Page 3 Subject to alterations without prior notice, errors and omissions excepted. E & OE. We wish you a lot of fun and success while exercising and working with your h/p/cosmos running machine. Franz Harrer President h/p/cosmos sports &...
  • Page 4: [1.] Introduction

    Introduction [1.] model view of some of the h/p/cosmos running machine series h/p/cosmos locomotion 150/50 DE med h/p/cosmos mercury h/p/cosmos quasar h/p/cosmos pulsar h/p/cosmos venus & h/p/cosmos saturn file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com...
  • Page 5 In case of alterations of the device or the additional equipment always the actual version of the manual or the according additional information has to be considered. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012...
  • Page 6: Table Of Contents

    EMC Electromagnetic Compatibility ........................34     [4.K5] General advice ..............................34     [4.L] h/p/cosmos medical running machines - MDD medical device directive. Safety standards ........... 35     file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 7 Mode of operation ................................64     [7.B1] General notes ..............................64     [7.B2] Acceleration levels / acceleration intensity ......................64     file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 7 of 213...
  • Page 8 Set back of oil message MCU with UserTerminal .................... 133     [9.E] Control and tightening of the running belt ........................134     file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 8 of 213...
  • Page 9 H andrails adjustable with gear tooth locking elements ....................168     [12.C1] Danger precaution and operation ........................169     file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 9 of 213...
  • Page 10   ®   [12.J] Wheelchair ramp ................................177     [12.K] h/p/cosmos wheel chair stabilizer for oversize running machines ................177     [12.L] Safety arch with chest belt and harness ........................178     [12.M] Running belt rotation reversible for downhill walk .................... 179  ...
  • Page 11     [16.J] Wiring diagram control circuit quasar med 5.0 / pulsar 5.0 – page 2 ................213     file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 11 of 213...
  • Page 12: [3.] Introduction

    A treadmill is an exercise machine for running or walking while staying in one place. The h/p/cosmos treadmill device is a stationary treadmill which is used for training and testing The medical versions can also be used for diagnostics and therapy applications.
  • Page 13: [3.D] Materials Used

    Software products such as h/p/cosmos para graphics, h/p/cosmos para analysis and h/p/cosmos para motion are only for fitness applications. The h/p/cosmos para control software is also not for medical evaluation and diagnosis but for remote control of the treadmills load parameter and for maintenance issues.
  • Page 14: [3.F] Mechanical Characteristics

    230 x 105 x 140 cm (90.6 x 41.3 x 55.1 inches). Running surface of the model “h/p/cosmos pulsar” for example is 190 x 65 cm / 74.8 x 25.6 inches, frame size 250 x 105 x 140 cm (98.4 x 41.3 x 55.1 inches), machine’s weight approx. 400 kg (884 lbs), max. subject weight on running deck: 200 kg (440lbs).
  • Page 15: [3.I] Specific Safety Or Performance Claims Made For The Device

    (for example the h/p/cosmos airwalk) is obligatory for such applications. Automatic stop of the running belt in the moment a fall occurs. The chest belt secures the subject and prevents falling over to the front. The chest belt straps do not pinch or restrict the athlete.
  • Page 16: [3.K] Pictures Of Safety Devices

    The treadmill also has standard safety features such as emergency button, potential isolation transformer and potential equalisation pin. potential isolation transformer potential equalisation pin Additional safety related information, articles and announcements see manufacturer’s website: http://www.h-p-cosmos.com/en/safety/index.htm file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 16 of 213...
  • Page 17: [4.] Safety, Warnings, Precautions, Prohibitions

    Valuable articles (like watches, emblazonments, etc.) must be abated before using the device and must also not be in near environment of the device. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 18: [4.B] Exit The Device In Emergency Case; Emergency Dismount

    All h/p/cosmos running machines have at least ONE electric emergency stop device, which result in the machine cutting off the main power of the motor and the inclination system without relying on any software functions.
  • Page 19 “PULL STOP” interface active, but no start, speed or elevation signal executed keyboard inactive file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 19 of 213...
  • Page 20 In all above mentioned cases all displays will reset to the value “0”, independent from the type of stop function and independent from the way, if the machine was cut off from main power or if the main power remained. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 21: [4.D] General Instructions / Safety

    This instruction manual is part of the device and must always be accessible for every user. Exact observance of the instruction manual is a requirement for the appropriate operation of an h/p/cosmos device. Holding the handrails during exercise may effect the exercise results (e.g. heart rate, ECG, EMG, oxygen uptake, etc.).
  • Page 22: [4.E] Instructions For Safety And Operation

    Patient security according to VDE 0750 (IEC 60601-1) type B R applied part [4.E2] If your h/p/cosmos device has a c mark with a 4-digit number (e.g. n) at the identification plate, it is a medical device. At your h/p/cosmos medical device the patient is protected/isolated from the mains in accordance with the safety standard referring to the requirements for leakage current values according to IEC 60601-1 applied part type B R.
  • Page 23: [4.E4] Connection Of Units Installed Outside Medically Utilized Locations

    [4.E4] If units installed outside medically utilized locations (e. g. external printer, host computer etc.) are connected to an h/p/cosmos unit installed in a medically utilized location the VDE 0750 regulations must be observed. Connection only via … 1. Optical fibre or optocoupler (4 kV checked and approved) or …...
  • Page 24: [4.E7] Protection Against The Danger Of Electrical Shocks

    (e.g. swimming pool, sauna, etc.) nor in environmental chambers. If not stated otherwise in the delivery information h/p/cosmos devices are designed for operation in normal climatic surroundings (IEC 60601-1): + 10 ° ... + 40 ° C...
  • Page 25: [4.F] Medical Device Software

    For this reason always the worst case of a malfunction has to be taken into account. h/p/cosmos classifies the internal firmware and software components as Class B due to a number of risk reducing design features and measurments.
  • Page 26: [4.G] Connection Of External Host And/Or Auxiliary Devices Via Interface

    All other interface protocols (older versions coscom v2, coscom v1, coscomekg.dll, Trackmaster, Pacer, etc.) are not validated by h/p/cosmos according to the norms EN 62304 and EN 14971 and must not be used for medical applications (e.g. ergometry, stress-tests, cardiorespiratory diagnostic, performance diagnostic, etc.) since March 21, 2010 in...
  • Page 27: Programmable, Electrical Medical Systems (Pems)

    In case the manufacturer declares multiple sockets as valid, these have not to be located on the floor, to prevent soaking of liquids and mechanical damage. h/p/cosmos herewith informs about all above and below mentioned risks, warnings and obligations. Responsibility for system integration: The operator of ME equipment and ME systems (ME=medical-electrical), has to appoint a so-called system integrator, responsible for taking care of the tasks that result from the norm.
  • Page 28 • Data Corruption • Inappropriate time allocation data • unexpected data received • non-authorized access to data • destructive data. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 28 of 213...
  • Page 29 (100 MB Ethernet, 1GB Ethernet, etc.), etc.? • Can an overloading of the network or data connections within the network node occur? file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 29 of 213...
  • Page 30 Breakdown of a tele-medic connection Table 1: Possible risks by severity and reaction time in case of data loss or disturbances of the network or data network respectively. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 31 As class B networks are usually radiologic networks, it is a problem to define the responsibility for such a system when several manufacturers allocate different modules. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 32 Table H.4 of the standard gives an example of a collection of parameters that are needed to describe a network or a data network to document and define. This list represents however only a draft, which is regarded as the start of a comprehensive documentation. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 33: Economic Life-Time

    Safety standards, norms [4.K] All h/p/cosmos running-machines are produced according to strict safety- and quality controls. The running machine must not be used, if the certificates/permissions and the (according to the list of technical specifications) defined safety standards do not correspond with the local and country-specific requirements. The country-specific requirements must be compared before initial operation.
  • Page 34: [4.K1] Vde / Iec En Norm

    Follow details to EMC values, guidance and manufacturers declaration in this manual in chapter „technical data“ General advice [4.K5] The device is assigned to overvoltage-category II and pollution level I. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 34 of 213...
  • Page 35: [4.L] H/P/Cosmos Medical Running Machines - Mdd Medical Device Directive. Safety Standards

    As a manufacturer it is h/p/cosmos’ duty, and as the distributor or end- user/operator of the running machine it is your duty, to minimize those dangers as far as possible.
  • Page 36 To reduce the risk for users, h/p/cosmos running machines have a gap of less than 4 mm and it is marked clearly with additional danger precaution stickers.
  • Page 37 Some examples for safety features at h/p/cosmos devices: Potential isolation Opto coupler board Potential equalization Shielded motor transformer connector cable Frequency inverter metal housing (for shielding) Medical devices are equipped with an Emergency-Off- Button instead of a conventional Safety-Stop-Button. The...
  • Page 38: Forbidden Use

    Please contact the manufacturer h/p/cosmos, if your doctor or specialist needs further information about the running machine.
  • Page 39: [5.] Application, Indication, Contra-Indication

    [5.A] All running-machines are built corresponding to the classes S,I,A based on EN 957-1 / EN 957-6. The indications, discussed in the following, can be treated by any h/p/cosmos treadmill version, although there are more or less recommended solutions. Professional application in sports and fitness (with c mark on nameplate) [5.A1]...
  • Page 40: [5.C] Risk And Benefit Of Treadmill Application

    The manufacturer releases the medical product for the described applications and indications. Clinical studies are obsolete and have not been ordered by h/p/cosmos by now, since there is a huge amount of literature, over 50 years of experience in application worldwide and the performance data according to EN 957-6.
  • Page 41: [5.C1] Summary / Potential Risk Remains

    Higher degree AV-blocking Physical and/or mental disabilities Also see following guidelines: Deutsche Gesellschaft für Kardiologie – Herz- und Kreislaufforschung e. V: http://leitlinien.dgk.org/ file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 41 of 213...
  • Page 42: Application Treadmill Ergometry: Cardiology Ecg Stress Test On The Treadmill

    The h/p/cosmos treadmill is equipped with several load protocols that can be chosen in the “test-mode” (see chapter ”operation”). You also have the possibility to create a sef-defined profile, either using the “graded test” or the “free deinable user profiles”.
  • Page 43: [5.F] Application Gait Analysis And Rehabilitation On The Treadmill With Force Measurement Plates

    (not for sports machines; only for medical running machines with n mark on nameplate) The h/p/cosmos Kistler gaitway is an h/p/cosmos treadmill of mercury size, equipped with two Kistler force measurement plates; it is the only h/p/cosmos treadmill with these features. The system is measuring the ground reaction force and thereby collecting a huge amount of gait parameter.
  • Page 44: [5.G] Application Gait Analysis And Rehabilitation On The Treadmill With Neurologic Patients

    (not for sports machines; only for medical running machines with n mark on nameplate) For neurologic application the h/p/cosmos locomotion with unweighting system airwalk se is the recommended solution. Neurologic gait therapy could be performed using any h/p/cosmos treadmill, but with less comfort.
  • Page 45: [6.] Installation & Commissioning

    Within Germany mostly all devices are delivered and assembled by h/p/cosmos directly or by an authorised forwarder. If delivered by h/p/cosmos the packaging will be taken back and recycled.
  • Page 46 Transport angle construction running surface 200 ... 300/75 ... 125cm [cos14090] Transport tool for construction size running surface 150/50cm [cos10972] Transport tool for construction size running surfaces 170 and 190/65cm [cos13794] file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 47: [6.A2] Transport With Trolleys

    The levelling sockets and the front wheels of the elevation system may cause a print in the flooring. In case of sensitive flooring please use h/p/cosmos floor mats for protection: Floor protection mat 150/50 for running machines with deck size 150x50 cm [cos14005]...
  • Page 48 (~ 500 kg) / m². At h/p/cosmos gaitway with integrated force plate the transportation locks have to be removed after erection. Drive elevation up to max of 25 %. Loosen the four M8 screws, indicated with the red arrows at the underside of the alu- force plates and remove them.
  • Page 49: [6.C] Electrical Installation

    To start again you have to switch-on the running machine at the main „ON“ switch and than press START at the keyboard. Installation of any electrical device and h/p/cosmos running-machines must only be carried out at a voltage power connection with ground wire (earthing) including leakage-current protection-switch (interrupter) and according to VDE 0100 or/and the currently valid regulations and directives.
  • Page 50: [6.C1] Name Plate

    Name plate [6.C1] picture left: name plate example sports device, model: h/p/cosmos quasar picture right: name plate example medical device, model: h/p/cosmos saturn 300/125r For full details please refer to the chapter „technical data“ in this manual. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com...
  • Page 51: [6.C2] Electric Safety Measurements And „First Measured Values

    One copy of this protocol [cos11690xx] remains at the owner’s manual and the original of the protocol with the „first measured values“ shall be sent to the manufacturer h/p/cosmos. Picture: Example for electric safety testing device based on IEC 601-1 Potential equalization [6.C3]...
  • Page 52: [6.C4] Plug Assignment At The Userterminal

    If the UserTerminal was disassembled during transport please connect the cables according to following illustration: Devices with MCU5 control unit (as of manufacturing date 12/2007) file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 52 of 213...
  • Page 53 & commissioning Devices with MCU4 control unit (until manufacturing date 12/2007) file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 53 of 213...
  • Page 54 & commissioning For devices with MCU4 control unit (until manufacturing date 12/2007) and reverse belt rotation file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 54 of 213...
  • Page 55 Above: Drawing cable connection for ON/OFF button and emergency stop in the UserTerminal Right hand side: Ground connection at the UserTerminal Note: GND / GND = ground file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 55 of 213...
  • Page 56: [6.D] Starting The Running Machines

    The indicator light within the key is glowing (if the indicator does not flash up, please check the power supply, the expulsion fuse and the Emergency-stop). file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 57: [6.D3] Switching The Device Off

    Devices for Sports and Fitness manufacturing before 12/2007 The machine can be switched off directly with the explusion fuse at the FrontTerminal (frontal section below the hood). file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 58: [6.E] Emergency-Stop / Emergency-Off

    / main mushroom head inclination system power type. display, keyboard and press START key, interface inactive or new command through interface file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 58 of 213...
  • Page 59: [6.F] Installation, Overview, Checklist

    The authorized technician (distributor or service partner) has to check whether the installation of the device has been performed properly, before the customer is introduced into the operation of the h/p/cosmos device. For detailed information and instructions for installation and commissioning please refer to all respective individual chapters in this manual.
  • Page 60 For details please refer to chapter „maintenance / inspections“. One copy of this protocol [cos11690xx] remains at the owner’s manual and the original with the „first measured values“ shall be sent to h/p/cosmos. The potential equalization cable has to be accomplished connected AFTER the measurements.
  • Page 61: [7.] Operation

    To control via USB interface the processor must be a Pentium 1.8 GHz or higher. To use all the functions described below and for maintenance and service we recommend the PC software h/p/cosmos para control (Freeware).
  • Page 62: [7.A1] The Keyboard

    (LED) in addition, which supply information about mode, measuring unit and so on. Flashing displays indicate: select option (LED alterable parameter (LCD) interference / error file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 62 of 213...
  • Page 63: The Display (Standard Configuration)

    M = male F = female ∠ ° year Step Weight Weight Height of subject H ..LED on / LED off file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 63 of 213...
  • Page 64: [7.B] Mode Of Operation

    7 different acceleration levels and deceleration levels are available for all modes and for remote control via interface and h/p/cosmos coscom protocol. Max. acceleration level and minimum acceleration level see chapter: User options / optional functions. The following diagram shows the acceleration levels at a running machine with maximum speed of 40km/h.
  • Page 65: [7.B3] Manual Mode

    Alteration of elevation Elevation is being increased / reduced (0 ... max.) as long as the key get pressed. press and hold file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 65 of 213...
  • Page 66: [7.B4] Automatic Mode

    Test No 21 ... 28 are user defined (free programmable Profiles). For a better and easier documentation we recommend to use the serial printer interface or to connect an external PC in order to use the h/p/cosmos para graphics for documentation.
  • Page 67 Herewith you can create more variations out of the 6 standard Profiles. Continue with A) [05] Stop running-belt Running belt stops. (Deceleration time can be adjusted in the optional functions) file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 67 of 213...
  • Page 68: [7.B6] Possibilities Of Interfering Into The Profile Mode Manually

    For a better documentation we recommend to use a printer linked to the serial interface or/and to use an external PC with the Software h/p/cosmos para graphics ® file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 69: [7.B7] Profile Outline

    Endurance interval standard Warming up High 1 Low 1 High 2 Low 2 High 3 Low 3 High 4 Low 4 25 min file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 69 of 213...
  • Page 70 High 3 10.0 Low 3 High 4 10.0 Low 4 High 5 10.0 Low 5 High 6 10.0 Low 6 25 min file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 70 of 213...
  • Page 71 Low 3 10.1 High 4 13.0 Low 4 10.1 High 5 11.5 Low 5 10.1 High 6 11.5 Low 6 10.1 25 min file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 71 of 213...
  • Page 72: [7.B8] Cardio Mode - General Notes

    Place the transmitter so that it is right below the pectoral muscle (chest), as is shown in the illustration above. For ca. 95 ... 98 % of the subjects the "normal" placement of the transmitter belt is recommended. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 73 1.0 km/h 1.0 % 10 Seconds 30.1 ... 50 1.5 km/h 1.2 % 8 Seconds > 50 2.0 km/h 1.6 % 7 Seconds file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 73 of 213...
  • Page 74: [7.B10] Cardio Mode - Operation

    35 (for the subject's age) years is glowing [05] Select personal age indicates flashing: 0 ... 100(for the age), from Firmware V3.02.4: 18 ... 100 file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 74 of 213...
  • Page 75 For a better documentation we recommend to use a printer linked to the serial interface RS232 or/and to use an external PC with the Software h/p/cosmos para graphics ® file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 76: [7.B11] Possibilities Of Interfering With The Cardio Mode Manually

    For example to start manual mode and simultaneous for a "cool-down" period without stop of the belt. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 76 of 213...
  • Page 77: [7.B12] Test Mode And Free Program Profiles - General Notes

    Acceleration level: 4 (adjustable from 1 to 5) Break time: 30 sec. (can be changed) STOP must be activated manually by the medical doctor. Continuation next page ... file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 77 of 213...
  • Page 78 Circuit (lap length): 200m (can be changed) Increment: 0.5 km/h (can be changed) STOP must be activated manually by the medical doctor when the subject is fully exhausted. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 78 of 213...
  • Page 79 0.32 km/h every minute STOP must be activated manually by the medical doctor when the subject is fully exhausted file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 80 (not for all models available) maximum speed of the treadmill. Time for reaching target speed in seconds: Standard: 10 seconds; adjustable from 0 to 99 seconds file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 80 of 213...
  • Page 81 15.5 km/h 1:30 min 0.0 km/h 600 m 16.5 km/h 1:30 min 0.0 km/h 600 m 17.5 km/h 1:30 min 0.0 km/h file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 81 of 213...
  • Page 82 19.0 km/h 1:00 min 0.0 km/h 500 m 17.0 km/h 1:15 min 0.0 km/h 600 m 15.0 km/h 1:30 min 0.0 km/h file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 82 of 213...
  • Page 83 20.0 km/h 0:45 min 0.0 km/h 300 m 20,0 km/h 0:45 min 0,0 km/h 300 m 20,0 km/h 0:45 min 0,0 km/h file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 83 of 213...
  • Page 84 11.0 km/h 10 % 1:00 min 12.0 km/h 10 % 2:00 min 12.0 km/h 11 % 2:00 min 12.0 km/h 12 % file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 84 of 213...
  • Page 85 8.0 km/h 8.0 km/h 12 % 8.0 km/h 15 % 8.0 km/h 18 % 8.0 km/h 21 % 8.0 km/h 24 % file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 85 of 213...
  • Page 86 0.0 km/h 3:00 min 27.0 km/h 0:30 min 0.0 km/h 3:00 min 28.8 km/h 0:30 min 0.0 km/h 3:00 min 30.6 km/h file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 86 of 213...
  • Page 87 0.0 km/h 18 % 3:00 min 14.4 km/h 18 % 0:30 min 0.0 km/h 20 % 3:00 min 14.4 km/h 20 % file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 87 of 213...
  • Page 88 14.3 km/h 2:30 min 14.3 km/h 2:20 min 11.2 km/h 0:10 min 13.4 km/h 1:00 min 19.3 km/h 1:00 min 15.0 km/h file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 88 of 213...
  • Page 89 For a better documentation we recommend to use a printer linked to the serial interface RS232 or/and to use an external PC with the Software h/p/cosmos para graphics ® file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 90: [7.B14] Test Mode - Operation

    80% of their max. heart rate ( 220 – age). The test duration and heart rate are measured immediately after finishing the 2 km distance. At h/p/cosmos devices the heart rate is measured every 500m due to higher accuracy.
  • Page 91 A serial printer or a PCL-printer with parallel/centronics plug und converter [cos10056] can be connected directly to the h/p/cosmos running machine. Following data can be printed after the UKK walk test even without using any PC: UKK fitness index, date, time, test duriation, distance, elevation, heart rate, age, sex, body-mass-index (BMI).
  • Page 92: [7.B16] Programing Example: Ukk Walk Test

    "P 0" flashing and at the same time an acoustic signal appears, the running machine cannot receive the heart rate of the subject. Check chest belt system. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 92 of 213...
  • Page 93: [7.B17] Programming-Example: Free Definable Profile

    For a better documentation we recommend to use a test result (Fitness index and printer linked to the serial interface RS232 or/and to use time) an external PC with the Software h/p/cosmos para graphics ® Programming-example: free definable profile [7.B17] Programming and correction of a free programmed test is possible in test mode „...
  • Page 94 [16] Select time 2 minutes [17] Confirm time indicates time (seconds): Value "2:00" is flashing [18] Select time 30 seconds file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 94 of 213...
  • Page 95 [37] Confirm acceleration level indicates speed: Value "0.0" is flashing indicates program step:" St. 5 " [38] Select der Speed 6.0 km/h file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 95 of 213...
  • Page 96 For a better documentation we recommend to use a printer linked to the serial interface RS 232 or/and to use an external PC with the Software h/p/cosmos para graphics ® file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 97: [7.B18] Possibilities Of Interfering In Test Mode Manually

    For a better documentation we recommend to use a printer linked to the serial interface RS 232 or/and to use an external PC with the Software h/p/cosmos para graphics ® file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 98: [8.] Optional Settings

    Optional settings serve for example as an acknowledgement of error notes on the display, or for the standard setting of the device: selection of RS232 interface protocol, etc. Remark for devices without UserTerminal: For optional settings on devices without UserTerminal an external UserTerminal or a connected PC with the software h/p/cosmos para control is required. ®...
  • Page 99: [8.A2] List Of User Options / Optional Functions

    List of user options / optional functions [8.A2] For devices without UserTerminal: An external UserTerminal or PC software h/p/cosmos para control is required ® to control the running machine via RS232 interface. Option Description Comment / Display [8.A2]...
  • Page 100 10 ... 250 (estimated weight) weight blinking The personal body weight is necessary for a more correct calculation (estimation) of the power and energy consumption. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 100 of 213...
  • Page 101 (can also be set with UP and DOWN) (further settings in user OP23 and administrator OP16 are necessary) file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 102 Various Ergospirometry OFF = RS232 not active / no protocol / interface deactivated systems support the h/p/cosmos coscom 1 = h/p/cosmos coscom v1, v2, v3 with Baudrate 9600 bps protocol. Individual adaptation ( standard setting COM 1 and COM 2) protocol request.
  • Page 103 NOT valid for control and operation via RS232-interface. In this case the acceleration and deceleration level is set in option no. 29 resp. set in the corresponding command of the h/p/cosmos coscom protocol. OP28 Maximum acceleration and deceleration §...
  • Page 104 For a correct printout the connected printer must be compatible with PCL printer language. For special characters the ISO 8859-1 (Latin-1) font is used. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 104 of 213...
  • Page 105: [8.A3] Standard Settings For The User Options

    0 = no single values, 1 ... 100 OP 53 Language settings for printer protocol English English, German, French, Spanish Portuguese, Hungarian file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 105 of 213...
  • Page 106: [8.B] Administrator Options

    Administrator options [8.B] The administrator options are only accessible by h/p/cosmos staff and authorised service engineers. The access is only possible with a special code which is not depicted here. Changing an administrator option might cause serious problems if you are not familiar with all the details. Therefore the h/p/cosmos service has to be contacted before doing any changes in the administrator options.
  • Page 107 According to the selected device type (in OPTION 03) the standard maximum speed will be indicated in the SPEED Display. Example: h/p/cosmos mercury 4.0 = 22.0 km/h; h-p-cosmos discovery 4.0 = 40 m/min For safety purposes (e.g. for beginners) the max. speed of every treadmill model can be limited.
  • Page 108 OFF = no comparison 6 = 6 % deviation is allowed 8 = 8 % deviation is allowed 10 = 10 % deviation is allowed file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 108 of 213...
  • Page 109 To activate the motor break it is necessary to additionally change some parameters at the frequency inverter. Ask the service department of h/p/cosmos sports & medical gmbh for detailed instruction. Attention! If the device is switched off or disconnected from...
  • Page 110 If the speed measurement is switched off in OP11, then OP34 will only report internal program absolutes. In the other case following values are stored: Running machine series h/p/cosmos mercury with special speed 10 km/h: Speed Calibration Value: 8.490 Inverter Frequency: 80.2 Hz...
  • Page 111 [8.B1] special speed 45 km/h: Speed Calibration Value: 2.874 Inverter Frequency: 125 Hz Running machine series h/p/cosmos pulsar 3p with 40 km/h: Speed Calibration Value: 2.874 Inverter Frequency: 110 Hz Running machine series h/p/cosmos pulsar 3p with special speed 45 km/h: Speed Calibration Value: 2.874...
  • Page 112 Appropriate protocols and inspection instructions are available at h/p/cosmos service. To provide for this an error message "E 02" "HELP" for the TSC-service interval will appear in the display after expiration of a time period of 12 month.
  • Page 113 After a service with lubricating the treadmill and performing all maintenance work the oil and service interval can be set back with option number OP47. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 113 of 213...
  • Page 114 10 volt. Note down the voltage at the service report! (not possible with digital control via RS485) Read off the speed and write down the value at the h/p/cosmos service report: OP 48: _____ km/h Stop the running belt with the STOP key.
  • Page 115 Note: At each emergency-stop the number of timeout errors is increased compulsorily by at least one numerator, because the transmission line to the FI is being interrupted by hardware. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 116 ( models h/p/cosmos venus since 1997) 4 = elevation control: linear motor for 0 - 24% elevation, increment sensor, lift range 240 mm (h/p/cosmos mercury models since 1997) 5 = elevation control: linear motor for 0 - 28% elevation, increment sensor, lift range 300 mm (h/p/cosmos quasar 4.0...
  • Page 117 Total distance (km) report: total distance in km reports km Difference to user option 02: the displayed value can also be changed. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 117 of 213...
  • Page 118 *Note: It is not allowed to change the total time of operation or the total distance of the running-machine to a value which does not match to the real value of the device. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 119: [8.B2] Standard Settings Of Administrator Options

    Distance between rungs in 0.1 cm ergometer) OP 34 Manual Speed Calibration (depending on the device type; Range from: 0 to 65535 OP 03) file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 119 of 213...
  • Page 120 Test-Profile 99 for endurance testing in 0 = Test 99 de-activated 0 = Testprofile 99 de-activated the factory / service 1 = Testprofile 99 activated file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 120 of 213...
  • Page 121: [8.B3] List Of Running Machines Types

    190 / 65 -5.0 km/h 45.0 km/h 25.0 % 2874 46.0 km/h For any questions about the correct device type, contact the h/p/cosmos service before doing any changes. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 122: [9.] Maintenance And Safety Inspections

    Preventive maintenance [9.A] The h/p/cosmos authorised service engineers are happy to help you in the case of occurring problems. A preventive maintenance can avoid problems in the future and is indispensable for the safety of such technical devices. Therefore ask for an annual preventive maintenance contract, which is highly recommended by the manufacturer, from our service department.
  • Page 123: [9.B] Immediate Maintenance

    Only a properly and regularly serviced device is safe. The maintenance of the devices has to be performed only by the service engineers authorized and certified by h/p/cosmos, preferrably within the scope of a maintenance contract. Regular inspections/examinations [9.C]...
  • Page 124: [9.C2] Protective Earth Resistance R Pe Measurement

    The measuring is to be performed with measuring devices for the isolation-resistance measurement according to VDE 0701/0702 (sports and fitness machines) or VDE 0751/IEC 60601-1 (medical devices). file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 124 of 213...
  • Page 125: [9.C4] Equivalent (Alternative) Leakage Current I

    120 volts on the metal housing and frame parts. Do not touch the device under test during this measurement! file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 125 of 213...
  • Page 126: [9.C6] Electric Safety Tester And Measurements

    Due to the test of the RCD switch it possibly comes, depending on the circuit of the building electricity, to a switch- off of the complete or a part of the power supply of the building. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 127: [9.D] Lubrication Of The Running Belt/Running Surface

    An h/p/cosmos authorized technical service engineer will then advise what corrective action needs to be taken. Only use original h/p/cosmos special oil. The use of other oils or the ignoring of the regular lubrication checks can lead to damage of the running belt, running deck or the lubrication system and a reduction of warranty liability.
  • Page 128 Special oil 0.25 l - bottle for sliding plate with manual lubrication [cos000200008001] Syringe 10 ml for lubrication of sliding plate [cos12181] file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 128 of 213...
  • Page 129: [9.D2] Lubricant Test

    The tissue needs to be pulled through the gap between running belt and running surface in a defined lenght in order to absorb a certain quantity of lubricant. Based on previous experience h/p/cosmos is able to evaluate the quantity of the oil film by measuring the weight difference. However, it needs to be considered that this test can only find out approximate values and trends and can never replace the direct survey by the authorized h/p/cosmos technician in the prescribet time intervals.
  • Page 130: [9.D3] Devices Without Userterminal And Without Automatic Oil-Pump

    Please contact h/p/cosmos to receive the special oil. The running belt should be lubricated after 1000 km (special devices might have different intervals) at the latest or/and after hearing dry grinding noises during operation. After lubrication the oil message has to be terminated with "OPTION 01".
  • Page 131: [9.D4] Devices With Userterminal & Automatic Oil-Pump (Models "R" For Cycle & Wheelchair)

    Thus at those models a lubrication test (tissue-test) according the instruction (available from h/p/cosmos) must be performed in the course of the obligatory yearly maintenance. The test must be sent back to h/p/cosmos afterwards for evaluation purposes.
  • Page 132 The device does not have a sensor, the oil-message does not extinguish automatically. After checking the oil-level, the message has to be quit with „OPTION 01“. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 133: [9.D5] Set Back Of Oil Message Mcu 4 Without Userterminal

    Special oil for sliding plate with automatic lubrication/0.25l-bottle [cos14007] Special oil for sliding plate with automatic lubrication/0.50l-bottle [cos13438] Set back of oil message MCU 4 without UserTerminal [9.D5] An external UserTerminal or the PC-software h/p/cosmos para control is required for this. Further instructions see ® "Devices with UserTerminal”.
  • Page 134: [9.E] Control And Tightening Of The Running Belt

    [2]. All bigger models are tightened at the front drive shaft [5]. Mark of 1000 mm [1] applied when belt [4] absolutely loose. Tighten belt, until mark expanded up to between 1004 and 1005 mm (= 0.4 to 0.5 %). file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 135: Adjustment (Centering) Of The Running Belt

    As long as the running belt returns to the centre at a speed of 12 km/h it is not necessary to readjust. The running belt remains in the adjusted position for a period of months if it has been done correctly. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 136: [9.G] Control And Tightening Of The Driving Belt

    The tension at the bottom trumm (see picture) must be between 98 Hz and 103 Hz (frequency at oscillation). The noise (at higher speeds) and the straight position of the driving belt need to be considered. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 137 < value 98: belt tension need correction. frequency > value 102: belt tension need correction. After changing the tension of the drive belt new check is necessary. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 138: [9.G2] Driving Belt With Timing-Belt System

    The cleaning of the surfaces of the treadmill can be done with a light moistened cloth. For disinfection h/p/cosmos recommends Bacillol plus [cos12179]. Before using cleaning and disinfection substances always test the compatibility of the material at bad viewable places.
  • Page 139: [9.J] Cleansing And Adjustment Of The Speed-Sensor/Light-Barrier

    Clean the optical elements in between the glass and the light barrier carefully. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 140: [9.K] Cleansing And Adjustment Of The Light-Barrier At Belt-Re-Entry-Zones

    Light barrier must not be exposed to dazzling flash light of cameras. They might turn off and stop the running belt abruptly. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 141: [9.L] Spare Parts & Consumables

    Spare parts & consumables [9.L] description picture order number Special oil (bottle 0.25 l) For h/p/cosmos running deck surface only for running applications cos000200008001 (not for bicycle and wheel-chair use!) and manual lubrication with "hand-pump" syringe) Syringe 10ml cos12181 For lubrication of running surface Special oil (bottle 0.50 l) for automatic lubrication...
  • Page 142 Non slip step stripe 1770x76mm cos100037va01 mains cable 5m cos15505-01 Main lead 5m 400V/16A CEE cos15555-01 Main lead 5m 400V/32A CEE-plug file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 142 of 213...
  • Page 143: [10.] Trouble Shooting

    Expulsion fuse / ON-OFF button 2-pole C16A Expulsion fuse, device fuse 3-pole C16A Secondary fuse isolation transformer 1-pole B16A Secondary fuse isolation transformer 3-pole C16A file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 143 of 213...
  • Page 144: [10.D] Interference Factor

    Pay special attention to the EMC (electro magnetic compatibility) data and manufacturer’s declaration in the chapter „technical data / EMC“ of this manual. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 145: [10.E] Voltage At The Device Housing / Electric Shock

    Electric devices, electric motors, transformer High-voltage transmission lines, also from trains Strong fluorescent tubes near by Central heating radiators Other electric devices file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 145 of 213...
  • Page 146: [10.F1] Troubleshooting Heart Rate Measurement System Polar

    In rare cases, after several years of use, malfunctions of the control unit are possible because of worn battery power. In this case contact the service department to change the battery of the control unit. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 147: [10.I] Error Messages / Error Codes

    Every 12 months a electric saftey inspection is due. See chapter maintenance in this manual. Contact authorized service engineer Set back error message (option 01) file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 147 of 213...
  • Page 148 Attention: Dangerous voltage and danger of being hurt when the device is open. Do not touch the parts inside the device file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 148 of 213...
  • Page 149 (instantaneous value) is at least the in Error search see E30. administrator-option 12 set percentage LOWER than the calculated value (debit- value) file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 149 of 213...
  • Page 150 At MCU5 control electronic (as of manufacturing date 12/2007) this error exclusively shows a defect of the option memory (FRAM). In this case, please contact h/p/cosmos and request a service technician. Optional setup restores to default factory setting and device...
  • Page 151 Parameter storage device fault E.PE E.PUE PU disconnection E.RET Retry count excess E.CPU CPU fault Option fault CPU fault CPU fault E.13 Internal circuit fault file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 151 of 213...
  • Page 152 (not all models) Running machine is still functioning (except chip card function) unknown chip-card-malfunction no card identified check chip-card insert correct chip-card reprogram chip-card file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 152 of 213...
  • Page 153: [10.I2] Devices Without Userterminal

    "5 times LONG (code for "0")" and 1 time SHORT + 4 times LONG (code for "1") will be repeated 3 times. Error Code list see: Devices with UserTerminal. The error messages have to be terminated with "OPTION 01". An external UserTerminal or a PC software h/p/cosmos para control is required for this.
  • Page 154: [11.] Technical Data

    6 LCD displays / 6 keys / display of mode and unit with LED. E: no Terminal (Display & Keyboard) „lt-models“ and „h/p/cosmos locomotion 150/50 E med“ have no UserTerminal (no display, no DE: Touchscreen keyboard). Control only via interface.
  • Page 155 When using a front-bar handrail (crossbar), the speed is limited to 5 km/h for safety reasons. Data of weight and measurements can deviate. Ask for further details and optional equipment or visit www.h-p-cosmos.com. Subject to technical alterations without prior notice. E & EO. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 156: [11.B] Running Machines, 170-190/65

    0.0 ... 28.0 % not applicable 0.0 ... 28.0 % - 25.0 % ... + 25.0 % Definition 0.1 % 0.1 % 0.1 % file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 156 of 213...
  • Page 157 (TO = 15 %) converts to approx. 5 full elevation cycles. Overload can result in temporary tripping of the fuse, but can be used again after short cool down period. Treadmills of the h/p/cosmos saturn series built approx. before January 2007 have a maximum elevation of 25%.
  • Page 158: [11.C] Running Machines, Oversize

    2000x750 2000x1000 2500x750 2500x1000 2500x1250 3000x750 3000x1000 3000x1250 4500x3000 [r] = suitable for bicycle and wheel chair application file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 158 of 213...
  • Page 159 (TO = 15 %) converts to approx. 5 full elevation cycles. Overload can result in temporary tripping of the fuse, but can be used again after short cool down period. Treadmills of the h/p/cosmos saturn series built approx. before January 2007 have a maximum elevation of 25%.
  • Page 160: [11.D] Emc Electromagnetic Compatibility. Guidance And Manufacturer's Declaration

    Please pay special attention also to the other EMC related chapters of this manual: Chapter: Safety, Installation, Operation, POLAR heart rate monitor: EMC Chapter: Error, Malfunction, possible interference file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 161 NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 162: [11.E] Compatibility Interface

    (components as well from h/p/cosmos as from other manufacturers). The clinical evaluation refers only to the h/p/cosmos treadmill and the „intersection risks“ (e.g. risk at stresstest until fatigue in treadmill ergometry with cardiorespiratory diagnostic) and does not extend to the optional components themselves.
  • Page 163: [11.E1] Interface Additional Information

    All other interface protocols (older versions coscom v2, coscom v1, coscomekg.dll, Trackmaster, Pacer, etc.) are not validated by h/p/cosmos according to the norms EN 62304 and EN 14971 and must not be used for medical applications (e.g. ergometry, stress-tests, cardiorespiratory diagnostic, performance diagnostic, etc.) since March...
  • Page 164 Medical running machines (treadmills) are active therapeutic devices and active diagnostic devices of the risk class IIb. Modern PC do not have a RS232 interface, but an USB interface. In this case h/p/cosmos offers a “interface converter USB / RS232”, article number cos12769. For treadmill control via USB interface the processor must be at least Pentium 1.8 GHz or higher.
  • Page 165: [12.] Accessories And Options

    The h/p/cosmos arm supports (patent no.: DE 199 16 508 A1) are available for the h/p/cosmos running machines with running deck size 150/50, 170/65 and 190/65 cm but not for running machines with adjustbale handrails.
  • Page 166: [12.A2] Reproducibility Of Adjustments

    6-degree steps. In the illustration below, which you can copy, e.g. for patient files, you can fill in the scaling datas for the individual adjustments of a patient. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 167: [12.B] Additional Keyboard And Add. Stop-Button For Arm Support And Remote Control

    With the long connection cable the therapist has the possibility to take over the control of the running machine e.g. from a kneeling position during locomotion therapy. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 168: [12.C] Handrails Adjustable With Gear Tooth Locking Elements

    6 keys incl. 2m spiral cord cos10106 mount for additional keyboard on arm support cos10111 h/p/cosmos additional stop button (red button on top of handgrip) for arm support right cos10107 h/p/cosmos additional stop button (red button on top of handgrip) for arm support left cos10108 mount for additional stop button on handrail with clamp for circular tube 60mm ¬...
  • Page 169: [12.C1] Danger Precaution And Operation

    While adjusting make sure that you do not pen in yourself or any other person at the danger spots (squeezing and jamming spots). Using the h/p/cosmos arm support with the adjustable handrails is not possible. Reproducibility of adjustments [12.C2]...
  • Page 170: [12.D] Handrails Adjustable. Parallel Bars With Gas Struts And Locking Lever

    If turing the UserTerminal to outside position, then at least 1 emergency-stop-button has to remain in reach of the subject at any time. The use of the h/p/cosmos arm supports is not possible with the adjustable bar handrails. Adjustment of the bar handrails [12.D2]...
  • Page 171 © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 172: [12.D3] Reproducibility Of Adjustments

    Operation and adjustment [12.E2] Point Illustration Action [01] Release the fixation screw underneath the foot support to adjust the optimal position. file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 172 of 213...
  • Page 173 Release the fixation screw underneath the seat to adjust the optimal seat position. [03] Fix the adjusted seat and foot support position by tightening the corresponding fixation screws Total view running machine h/p/cosmos locomotion 150/50 DE med file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012...
  • Page 174: [12.F] Special Handrails

    2 pillars handrail detachable / separable Details and order numbers are available at the manufacturer h/p/cosmos or at your local authorized distributor. The crossbar always needs to be positioned in that way that at least 2/3 of the running surface behind the crossbar is free for the user.
  • Page 175: [12.G] H/P/Cosmos Airwalk Se 135 (Available As Of 10/2008)

    135 (available as of 10/2008) [12.G] The „h/p/cosmos airwalk se 135“ is a user friendly and novel dynamic unweighting system with central point suspension for manual locomotion therapy. It improves the manual training due to constant un-weighting of the patient in the vertical movement area.
  • Page 176: [12.H] Unweighting System H/P/Cosmos Airwalk

    It is possible to use the h/p/cosmos airwalk with the running machine series with track size 150/50cm or 170/65cm or 190/65cm, and as well with most running machines produced by other manufacturers.
  • Page 177: [12.I] H/P/Cosmos Robowalk ® Expander

    [12.K] With the help of the h/p/cosmos wheel chair stabilizer it is easy to keep wheel chairs with 4 or 3 wheels safely in lane. The guide rail is fixed between the two pillars of the right-hand side handrail.
  • Page 178: [12.L] Safety Arch With Chest Belt And Harness

    The ceiling height should be at least 2.46m / 97.6 inches (0 % elevation) rsp. 2.57 / 101.6 inches (24 %) if used with h/p/cosmos mercury and 2.51 / 96.5 inches (0 %) rsp. 2.68 m / 105.5 inches (max. elevation) if used with running machines h/p/cosmos quasar or h/p/cosmos pulsar.
  • Page 179: [12.M] Running Belt Rotation Reversible For Downhill Walk

    [cos10079] (indicate model of running machine) Chest-harnesses, patient-vests, waist-belts with leash and cuffs are not designed for direct skin or mucous membrane contact. Wear appropriate clothing.
  • Page 180: [12.M1] Pull Cord Actuator (Lanyard + Magnet)

    “PULL STOP” interface active, but no start, speed or elevation signal executed keyboard inactive file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 180 of 213...
  • Page 181: [12.M2] Change From Forward To Reverse Rotation

    Bottle holder [12.N] The bottle holder is available for all h/p/cosmos running machines and can be easily fixed with a clamp on the handrail. The position of the bottle holder must not be at the rear end of the handrail due to this end must be reachable for the subject.
  • Page 182 For h/p/comos running machines with MCU5 and pre- installed UserTerminal housing and blind cover cos100565. h/p/cosmos "lt-models" (example h/p/cosmos mercury lt med) manufacturing date from approx. middle of January 2009. Instead of the existing blind-cover on the pre-installed UserTerminal a circuit board with displays cos14292...
  • Page 183: [12.P] Retrofitting / Additional Safety Stop / Emergency Stop

    10m (incl. 10m conecting cable) external emergency stop button with magnetic holder for easy fixation on h/p/cosmos running machines, for example on handrail with diameter 60mm Cable 10 m (no spiral cord) Plug: 3 pin XLR male cos15933 emergency stop-button magnet holder 5m (incl.
  • Page 184: [12.Q] Monitor / Laptop Arm

    A movable monitor and laptop arm for the external control unit of the oversize running machines h/p/cosmos saturn and h/p/cosmos venus is optionally available. Using this arm, the monitor also can be turned in the field of vision of the athlete or patient.
  • Page 185: [12.S] Digital (Serial) Rs232 Interface / Usb Converter

    Running-Machine from another controlling device (ECG. o.a.) or with the appropriate Software from a PC, via interface. Standard for all devices is ONE serial interface COM 1. Optionally there are further serial interfaces COM 2, COM3 and COM4 available. For further information please contact your local dealer or h/p/cosmos. The interface protocol h/p/cosmos coscom is available on request or can be found at www.coscom.org.
  • Page 186: [12.S3] Interface Cable For Connection Ergospirometry Jaeger/Viasys/Cardinalhealth/Carefusion Oxycon

    OXYCON Alpha / Delta / Champion / Pro: Connect the running machine interface with an available serial interface (COM1 ... COM4) at the PC of the OXYCON. Do not use the female connector at the OXYCON with the letters "treadmill / running machine". Important: From January 2000 use h/p/cosmos coscom RS232 interface protocol ©...
  • Page 187: [12.T] Printer Protocol

    RS232 of the running machine. Attention: For a printer with a parallel interface you will need a commercial interface- converter, available in every computer-store, at your local dealer or from the manufacturer (h/p/cosmos order no. [cos10056]). If Option 20: 3 is chosen (printer protocol see list of options), following data will be printed out: Interface converter for printer [cos10056] file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc...
  • Page 188: Polar Heart Rate Measurement System

    Note: Even with using the coded senders the transmission of the heart rate to the treadmill is still un- coded. The models h/p/cosmos locomotion and h/p/cosmos pulsar and h/p/cosmos venus and h/p/cosmos saturn have the POLAR W.I.N.D. transmitter with WearLink technology and coded transmission.
  • Page 189: [12.U4] Battery Of The Transmitter

    ® already well-known version 3.0. In addition to the pure remote control function of h/p/cosmos treadmill-ergometers over the pc the software has integrated now a lot of additional functions such as an option setting configuration tool with integrated storage function, firmware update over flash eprom, quick-stop-key, cool-down-key, pause-key, target speed settings, target elevation settings, stop-count-down, display reset, etc.
  • Page 190 & options h/p/cosmos para control can be found on the h/p/cosmos demo & info DVD [cos10067] which is delivered together ® with every h/p/cosmos treadmill-ergometer. Alternatively the software can be downloaded at www.h-p-cosmos.com/en/software. At aforementioned link also a manual can be found in which all functions of the new para control are described in detail.
  • Page 191: [12.W] Pc Software H/P/Cosmos Para Graphics

    The software is not designed for medical use. The data can be converted by the software and be taken over and evaluated e.g. by EXCEL, or h/p/cosmos para analysis software. A take over and processing of the data within a spreadsheet (EXCEL, etc.) or an editor is also possible with the help of the h/p/cosmos para graphics ®...
  • Page 192: [12.X] Pc Software H/P/Cosmos Para Analysis

    It is possible to enter the test data in h/h/p/cosmos para analysis usually or by importing it from h/p/cosmos para graphics clear design of the program ®...
  • Page 193: [12.Y] Pc Software H/P/Cosmos Para Motion

    PC Software h/p/cosmos para motion [12.Y] The h/p/cosmos para motion is a software for recording and evaluation of video analysis with individual report for printout, incl. control functions of h/p/cosmos running machines. The software is not designed for medical use.
  • Page 194: [13.] Certificates

    Certificates [13.] Certificate of the TSA (TÜV) according to ISO 9001 [13.A] file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 194 of 213...
  • Page 195: [13.B] Certificate Of The Tsa (Tüv) According To En Iso 13485

    Certificate of the TSA (TÜV) according to EN ISO 13485 [13.B] file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 195 of 213...
  • Page 196: [13.C] Ec Certificate Of The Tsa (Tüv)

    EC Certificate of the TSA (TÜV) [13.C] file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 196 of 213...
  • Page 197: [13.D] Certificate Of Compliance For Sports And Fitness Devices

    Certificate of compliance for sports and fitness devices [13.D] file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 197 of 213...
  • Page 198: [13.E] Certificate For Medical Devices

    Certificate for medical devices [13.E] file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 198 of 213...
  • Page 199 © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 199 of 213...
  • Page 200 © 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 200 of 213...
  • Page 201: [14.] Disposal

    Disposal [14.] By request and at the expense of the client h/p/cosmos might take over the disposal of old devices and devices not longer functioning. Please contact service@h-p-cosmos.com for a detailed offer. Note the information for possible disposal of the running machine parts or components through the client or a subcontractor.
  • Page 202: [15.] Contact

    & production Am Sportplatz 8 DE 83365 Nussdorf-Traunstein Building 2 (picture below) h/p/cosmos sales & service Feldschneiderweg 5 DE 83365 Nussdorf-Traunstein file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 202 of 213...
  • Page 203: [16.] Appendix - Instruction And Commissioning

    After the instruction is completed the instruction protocol is to be signed by the h/p/cosmos technician and all trained persons and sent back, together with the signed delivery note and the registration form, to h/p/cosmos.
  • Page 204: [16.B] Instruction Into Functions

    [05] Operation of running machine via program mode. Refer to the list of programs in the instruction manual. accomplished file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 204 of 213...
  • Page 205 Do not connect to equipment or software, which is not explicitly declared as compatible by h/p/cosmos and by the other manufacturer. Inform about the h/p/cosmos software programs h/p/cosmos para control, h/p/cosmos para graphics, h/p/cosmos para analysis and h/p/cosmos para motion for documentation and visualization of data.
  • Page 206: [16.C] Instruction Into Maintenance Works

    [04] Lubrication of running belt when "OIL"-message (quantity, intervals according to instruction manual, spread the oil by "Duck-walking"). Use only original h/p/cosmos lubricant authorized for this model of running machine. Observe demand for additional lubrication based on manual. After running belt lubrication the position of the running belt must be checked once more and be adjusted if necessary.
  • Page 207: [16.D] Advice And Support Documents

    [16.D] [01] Hand over and explain delivery papers (folder). Fill out registration form and send it to h/p/cosmos sales. Let the customer sign the delivery note and instruction protocol and send it back to h/p/cosmos sales immediately. Ask for brochure of customer and send it to the sales department at h/p/cosmos.
  • Page 208: [16.E] Confirmation Of Commissioning And Introduction / Instruction

    Please fill out the instruction protocol and send back to h/p/cosmos via Fax to +49 86 69 86 42 49, via email to sales@h-p-cosmos.com or via post h/p/cosmos sports &...
  • Page 209: [16.F] Service Report - Cos15531

    Service report – cos15531 [16.F] file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 209 of 213...
  • Page 210: [16.G] Control Protocol - Cos11690En-02

    Control protocol – cos11690en-02 [16.G] file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 210 of 213...
  • Page 211: [16.H] W Iring Diagram Load Circuit Quasar Med 5.0 / Pulsar 5.0

    Wiring diagram load circuit quasar med 5.0 / pulsar 5.0 [16.H] Color Code not US / not Canadian standard! file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 211 of 213...
  • Page 212: [16.I] Wiring Diagram Control Circuit Quasar Med 5.0 / Pulsar

    Wiring diagram control circuit quasar med 5.0 / pulsar 5.0 – page 1 [16.I] Color Code not US / not Canadian standard! file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 212 of 213...
  • Page 213: Wiring Diagram Control Circuit Quasar Med 5.0 / Pulsar

    Wiring diagram control circuit quasar med 5.0 / pulsar 5.0 – page 2 [16.J] Color Code not US / not Canadian standard! file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc © 2012 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 213 of 213...