h/p/cosmos 150/50 mercury Operating And Service Manual page 141

Running machine series
Table of Contents

Advertisement

Dimension frame
length x width x height
Track access height from floor
(optional installation in pit)
Weight of device
Weight load limits to floors
(traffic load to DIN 1055 part 3)
Max. permissible user weight on running
surface
Environmental conditions:
Transport and storage
Environmental conditions:
Operation
Pollution degree
Central lubrication system
Number of stored programmes
RS232 Digital interface / serial port
Heart rate measurement and heart rate
dependent endurance control (target pulse
programming)
PC software
(not for medical application)
Reverse belt rotation / downhill
Safety arch with chest belt system***
Wheel chair stabilizer
Monitor arm and laptop computer
* Overload and weak power supply (undervoltage) could lead to higher discrepancies concerning the speed display or dripping of the fuse.
** The time of operation of the elevation motor (TO = 15 %) converts to approx. 5 full elevation cycles. Overload can result in temporary tripping of the fuse,
but can be used again after short cool down period. Treadmills of the h/p/cosmos saturn
elevation of 25 %.
*** For maximum stress tests and with oversize running machines (track sizes) a safety facility (e.g. a safety arch with chest belt system) is necessary and
highly recommended. When using a front-bar handrail (crossbar), the speed is limited to 5 km/h for safety reasons. Data of weight and measurements can
deviate.
Ask for further details and optional equipment or visit www.h-p-cosmos.com. Subject to technical alterations without prior notice. E & OE.
© 2012 h/p/cosmos sports & medical gmbh
2400 x
2400 x
1150 x
1400 x
1380
1380
850 kg
900 kg
9.0
7.5
kN/m²
kN/m²
In case of any further questions related to load limits onto floors, please ask our service department.
temperature: –30...+50 °C, humidity: 0...95 % - without condensation
barometric pressure: 700...1060 hPa
temperature: +10...+40 °C (deviation on request), humidity: 30...70% - without condensation
(up to 95% on request), barometric pressure: 700...1060 hPa
Maximum operating altitude: approx. 10,000 feet (3000m), without pressurization
Degree 2: Normally only nonconductive pollution. Temporary conductivity caused by condensation is to
manual / running machines with [r] have automatic central lubrication system
6 training profiles / 10 test profiles / 8 user defined profiles
COM1: standard; COM2: standard; COM3: optional (standard for service); COM4: optional
h/p/cosmos para control
option: h/p/cosmos para analysis
file: n:\article\cos14310m5-v1_06hpc-en\20120504_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.docx
email@h-p-cosmos.com
2900 x
2900 x
2900 x
1150 x
1400 x
1650 x
1380
1380
1380
480 mm
950 kg
1000 kg
1050 kg
7.7
6.5
5.6
kN/m²
kN/m²
kN/m²
280 kg
(deviation on request specially made)
be expected.
POLAR W.I.N.D. with WearLink
coded transmission
transmission range approx. 10 m
and h/p/cosmos para graphics
®
, h/p/cosmos para motion
®
standard
option
option
option
series built approx. before January 2007 have a maximum
®
created 04.05.2012
printed 04.05.2012
technical data
3400 x
3400 x
3400 x
1150 x
1400 x
1650 x
1380
1380
1380
1100 kg
1150 kg
1250 kg
7.0
5.8
5.1
kN/m²
kN/m²
kN/m²
included
®
®
page: 141 of 191
on request
dep. on
installation
on request
dep. on
installation
on request
dep. on
installation
on request

Advertisement