9.10

Error messages

Interferences and error codes might be caused by problems with the power supply or because of insufficient
maintenance (lubrication of the running surface, etc.).
Check voltage supply. Do not use extension cords or multi-way connectors. Connect the machine directly to the
N
socket in the wall. Each machine should have an individual circuit.
Check mechanical parts for any malfunction. Check also for towels or other objects which might interfere with the
N
drive system.
Check if any light barriers are dusty or incorrectly adjusted.
N
Check lubrication of the running belt and lubricate if required.
N
Contact problems at connectors (loose connections) caused by vibrations can result in malfunctions. Therefore
N
please check cables and connectors for loose connections.
The device has a self-diagnosis which recognizes some errors and displays error messages at the MCU UserTerminal
or the frequency changer/inverter (inside the device).
Error messages on devices with UserTerminal
Initiation: Running belt is not moving. One of the mode LED
Message Description
E01
Oil interval due
E02
Service interval due
or
safety inspection due
E20
Elevation system
exceeded
max. value
© 2012 h/p/cosmos sports & medical gmbh
Explanation / Display / Activity
=
!
E 01
§ $ %
Running machine is still functioning
Every 1000 km (interval is adjustable) lubrication service is due. See chapter
N
"lubrication of the running belt". Lubricate the belt.
Attention: Error message does not disappear automatically,
N
reset error message (OP 01)
=
!
E 02
§ $ %
Running machine is still functioning
Every 5000 km (interval is adjustable) general service including interior
N
cleansing, checking the driving belt, running belt, etc. is due.
Every 12 months an electric saftey inspection is due. See chapter maintenance
N
in this manual.
Contact authorized service engineer
N
Reset error message (option 01)
N
=
!
E 20
§ $ %
Running machine is still functioning (except for the lift device),
Lifting element exceeded the maximum value. The combined 0% / maximum % -
N
contact has been activated
Incorrect measurement of angle of elevation
N
Maybe wrongly adjusted, dirty or defective elevation sensor
N
Contact authorized service engineer
N
file: n:\article\cos14310m5-v1_06hpc-en\20120504_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.docx
email@h-p-cosmos.com
is flashing: (manual, profile, cardio, test)
OIL flashing
HELP flashing
Service flashing
HELP flashing
ELEV flashing
HELP flashing
created 04.05.2012
printed 04.05.2012
trouble shooting
page: 117 of 191