h/p/cosmos 170-190/65 Series Original Instructions Manual

h/p/cosmos 170-190/65 Series Original Instructions Manual

Hide thumbs Also See for 170-190/65 Series:
Table of Contents

Advertisement

models
stellar lt
stellar lt med
stellar
stellar med
quasar lt
quasar lt med
quasar
quasar med
pulsar lt
pulsar
locomotion
190/65 E med
locomotion
190/65 DE med
h/p/cosmos sports & medical gmbh
The copyright of this document, media, design, software and intellectual property is owned by
h/p/cosmos sports & medical gmbh, except where explicitly stated differently.
Warning: All rights reserved. Unauthorized copying, reproduction, hiring, lending,
public performance and broadcasting prohibited.
quasar med 3p
pulsar lt 3p
pulsar 3p
locomotion
®
190/65-3p E med
locomotion
®
190/65-3p DE med
®
®
quasar
®
original instructions for use
treadmill h/p/cosmos
IMPORTANT! READ CAREFULLY BEFORE USE!
article number: cos105000_170-190_65_en
170-190/65
®
KEEP FOR FUTURE REFERENCE!
date: 13.12.2018
firmware version: v1.08.x
revision: 1.03
run ahead of time
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 170-190/65 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for h/p/cosmos 170-190/65 Series

  • Page 1 The copyright of this document, media, design, software and intellectual property is owned by run ahead of time ® h/p/cosmos sports & medical gmbh, except where explicitly stated differently. Warning: All rights reserved. Unauthorized copying, reproduction, hiring, lending, public performance and broadcasting prohibited.
  • Page 2 3p pulsar lt 3p locomotion 190/65-3p E med ® ® ® [cos30003va26] [cos30004va02] [cos30024va02] pulsar ® locomotion 190/65-3p DE med ® [cos30004va04] [cos30024va04] © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 2 of 99...
  • Page 3 These instructions for use include all of the information needed to operate the device correctly and safely. Please read them carefully before use and keep them available at all times. We hope you will have a lot of fun and success as you work with your h/p/cosmos device. Franz Harrer President & CEO h/p/cosmos sports &...
  • Page 4: Table Of Contents

    4.6 Unauthorized access ..........................25 4.7 Residual risk / Side effects (med) ......................25 4.8 Firefighting ...............................25 4.9 All-pole disconnection ..........................25 5 Preparation ..............................26 5.1 Further preparation locomotion .......................27 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 4 of 99...
  • Page 5 11.6 Safety inspection ...........................51 11.7 Spare parts and consumables .......................51 12 Troubleshooting ............................52 12.1 General troubleshooting ........................52 12.2 RS232 troubleshooting ..........................53 12.3 Error messages .............................53 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 5 of 99...
  • Page 6 17 Annex I ................................65 17.1 Installation .............................65 17.2 Commissioning and instruction protocol ....................66 17.3 Commissioning and instruction protocol, signatures ................67 17.4 User Options OP (details) ........................68 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 6 of 99...
  • Page 7 Crossbar front rail [cos16571-01; cos15133-03; cos100947-01; cos100948-01; cos100949-01] ....96 Footboard extra wide 170 / 190 [cos10228, cos102289, cos16586, cos14764] ...........97 Wheelchair ramp [cos16186-02], [cos102931], [cos14664-03] ..............98 20 Contact .................................99 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 7 of 99...
  • Page 8 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 8 of 99...
  • Page 9: Symbols And Labels

    (IEC 60417-5032) Applied part of type B (IEC 60417-5840) Manufacturer (ISO 15223-1) Manufacturing date (ISO 15223-1) 2018-10-01 Separate collection for electrical and electronic equipment (2012/19/EU) © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 9 of 99...
  • Page 10: Symbols Used (Transport)

    Pages marked with the following symbol are valid for medical devices, only. sport sport Pages marked with the following symbol are valid for sports devices, only. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 10 of 99...
  • Page 11: Labels On Device

    1.4 Labels on device In case of any visible or assumed wear and tear (of the device, accessories, labels, etc.), unplug device, exclude reconnection, mark clearly and inform h/p/cosmos service personnel via telephone and writing. Do not change or remove any labels! Illustration...
  • Page 12: Description

    The decision regarding the correct load is the responsibility of the medical doctor. Depending on the application, the load includes speed, elevation, distance, heart rate, body weight or motion support, etc.. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03...
  • Page 13: Intended Use (Med)

    The treadmill is purely used as a stressing device and training equipment. * Devices marked with an “r” or "rs" like “h/p/cosmos saturn 250/75 r” are intended for applications with wheels as well. Applications with wheels include cycling, roller skiing, wheelchair applications, etc...
  • Page 14: Contraindications

    In case of relative contraindications permanent observation of the subject by medical staff is obligatory. Sources: http://leitlinien.dgk.org (German Cardiac Society) www.acc.org (American College of Cardiology Foundation) www.americanheart.org (American Heart Association) http://my.americanheart.org/idc/groups/ahaecc-internal/@wcm/@sop/documents/downloadable/ucm_423807.pdf © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 14 of 99...
  • Page 15: Intended Use (Sport)

    ❚ * Devices marked with an “r” or "rs" like “h/p/cosmos saturn 250/75 r” are intended for applications with wheels as well. Applications with wheels include cycling, roller skiing, wheelchair applications, etc... 3.2 Intended operator Persons carefully trained according to these instructions for use.
  • Page 16: Contraindications

    (American College of Cardiology Foundation) www.americanheart.org (American Heart Association) http://my.americanheart.org/idc/groups/ahaecc-internal/@wcm/@sop/documents/downloadable/ucm_423807.pdf Sources: http://leitlinien.dgk.org (German Cardiac Society) www.acc.org (American College of Cardiology Foundation) www.americanheart.org (American Heart Association) http://my.americanheart.org/idc/groups/ahaecc-internal/@wcm/@sop/documents/downloadable/ucm_423807.pdf © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 16 of 99...
  • Page 17: Safety (Med)

    * Devices supplied with the special “running belt for ski and spike applications” (see “Annex III (Accessories)”) are intended for application with spikes or studs as well. ** Devices marked with an “r” or “rs” like “h/p/cosmos saturn 250/75 r” are intended for applications with wheels as well. Applications with wheels include cycling, roller skiing, wheelchair applications, etc.
  • Page 18 ❚ mark clearly and inform h/p/cosmos service personnel via telephone and writing. Do not change or remove any labels! In case of any fluid entering into the device, unplug device, exclude reconnection, mark clearly and inform h/p/cosmos service ❚ personnel via telephone and writing.
  • Page 19: Safety (Sport)

    4 Safety (sport) h/p/cosmos medical treadmills may be operated with healthy subjects as well. The safety notes, warnings and precautions have to be pointed out to every user and operator and displayed within sight of the running machine. 4.1 Safety information – Forbidden use...
  • Page 20 ❚ mark clearly and inform h/p/cosmos service personnel via telephone and writing. Do not change or remove any labels! In case of any fluid entering into the device, unplug device, exclude reconnection, mark clearly and inform h/p/cosmos service ❚ personnel via telephone and writing.
  • Page 21: Fall Prevention Devices

    (airwalk). It is up to the operator to use any other device that prevents the subject from falling and complies with IEC60601-1.
  • Page 22 Select the user position on the treadmill using the safety arch. In order to re-open the buckle, press the fastener with thumb and index finger. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 22 of 99...
  • Page 23: Emergency Dismount

    Inform the third person that you will open the buckle of the safety harness ❚ Open the buckle of the safety harness. ❚ Subject will slide into the other person’s arms. ❚ Render first aid. ❚ © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 23 of 99...
  • Page 24: Emergency Off

    Release cord Mains connection and Interface communication not interrupted Restart application Pull cord with magnet from Reconnect magnet with metal plate cord to metal plate © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 24 of 99...
  • Page 25: Unauthorized Access

    However, the risk of injury or even death due to a malfunction of the treadmill is very low. In over 30 years of history and with more than 10,000 h/p/cosmos treadmills on the worldwide market, there has never been such a reported incident.
  • Page 26: Preparation

    (running belt might slip through due to gravity). Holding handrails during use affects exercise results. (running belt might slip through due to gravity). © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 26 of 99...
  • Page 27: Further Preparation Locomotion

    Adjustment of therapist seats Release fixation ❚ Adjust seat ❚ Tighten fixation ❚ Adjustment of foot rest Release fixation ❚ Adjust foot rest ❚ Tighten fixation ❚ © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 27 of 99...
  • Page 28: Userterminal

    Always the latest command will be executed, regardless of whether it came via interface or from the UserTerminal during one of the four modes. Only stop command has higher priority and cannot be overwritten. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03...
  • Page 29: Standard Vs. "Lt" Devices

    6.2 Standard vs. “lt” devices Most h/p/cosmos treadmills are available as standard or “lt” (light) devices. “lt” devices have no UserTerminal (no display, no keyboard). Standard device “lt” device Control via Control via - UserTerminal - Software (see “accessories”) - Software (see “accessories”) - additional keyboard (see “accessories”)
  • Page 30: Connection Of External Devices / Interfaces

    Possible connection for remote control Possible connection for emergency stop devices. Additional Stop 2 Possible key switch for belt rotation Possible connection for emergency stop devices. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 30 of 99...
  • Page 31: Position Of Subject And Operator

    There must be no electrical devices within this area, which are not part of an ME-System with the device. Do not touch the subject and external electrical devices at the same time. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03...
  • Page 32: Operation

    Switch the running machine off with the on/off switch (light goes off) Disinfect the device (see “cleaning”). Disconnect the device and all accessories from mains power supply before cleaning or disinfection. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 32 of 99...
  • Page 33: Overview Of Operation Modes

    Confirm and start mode Adjust parameters, indicated by LEDs Confirm profile Terminate application Test mode Select mode Confirm and start mode Select test Confirm test Terminate application © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 33 of 99...
  • Page 34: Manual Mode

    Adjust elevation with “up” or “down“ Current elevation is displayed in “elevation” display To predefine stop time, see OP08 in Terminate the operation with “stop” “User Options”. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 34 of 99...
  • Page 35: Profile Mode

    14.4 01:00 10.1 02:00 t in min 13.0 01:00 10.1 02:00 11.5 01:00 t in min 10.1 02:00 11.5 01:00 10.1 04:00 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 35 of 99...
  • Page 36 Terminate the operation with “stop”. For possibilities to interfere with an automatic program, see “interfere with an automatic program”. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 36 of 99...
  • Page 37: Cardio Mode

    In case of any visible or assumed defects or malfunctions (of the device, accessories, software, etc.), unplug device, exclude ❚ reconnection, mark clearly and inform h/p/cosmos service personnel via telephone and writing. Start and load changes within the automatic modes are indicated by acoustic signals (beeps).
  • Page 38 It is possible to read out the data of the whole treatment via RS232 interface. The minimum resolution is 1/s. The data do not remain through restart or in case of power failure. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 38 of 99...
  • Page 39 03 Conconi test 10 Ramp profile Terminate the operation with “stop”. For possibilities to interfere with an automatic program, see “interfere with an automatic program”. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 39 of 99...
  • Page 40: Interfere With Automatic Program

    Cardio mode only: Change heart rate upper limit Heart rate lower limit follows Press “enter” together with “up” or according to initial range. “down“. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 40 of 99...
  • Page 41: Pause Function

    Pressing the “stop” key one time, terminates the application. All values remain on the display for 2 minutes. Pressing the “stop” key a second time, resets all values. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03...
  • Page 42: Acceleration Levels

    0.152 0.185 0.210 0.337 0.174 0.313 0.382 0.434 0.694 0.347 0.625 0.764 0.868 1.389 0.556 1.000 1.222 1.389 2.222 0.926 1.667 2.037 2.315 3.704 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 42 of 99...
  • Page 43: User Options

    3 s. Select option with “+” or “-“ Confirm with “enter”. Adjust option with “+”or “-”. Confirm with “enter”. Leave options by pressing “cancel”. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 43 of 99...
  • Page 44 OP 21 RS 232 interface protocol: COM 2 OFF, 1 ... 18 OP 23 RS 232 interface protocol: COM 4 OFF, 18 … 23 (20 = h/p/cosmos coscom v3) OP 27 Min. acceleration and deceleration level 1 ... 5 OP 28 Max.
  • Page 45: Accessories / Compatible Devices

    Additional keyboard for arm support locomotion Remote control Optional cos12922 Extension cord 2m additional keyboard Remote control Optional cos10111-01 Keyboard holder for arm support Remote control Optional © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 45 of 99...
  • Page 46: Compatible Devices

    Optional (*) At least one kind of fall prevention is mandatory, see “safety”. 9.3 Compatible devices A number of devices as well as software products are compatible with h/p/cosmos treadmills via coscom v3 interface protocol. Please contact service@hpcosmos.com for the list of compatible devices.
  • Page 47: Disinfection / Cleaning

    − Use a damp cloth (not wet). − Wipe all surfaces. − Wash safety harness acc. to label. The h/p/cosmos devices are neither sterile nor can they be sterilized. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03...
  • Page 48: Maintenance

    ❚ mark clearly and inform h/p/cosmos service personnel via telephone and writing. Do not change or remove any labels! In case of any fluid entering into the device, unplug device, exclude reconnection, mark clearly and inform h/p/cosmos service ❚ personnel via telephone and writing.
  • Page 49: Lubrication

    For further and precise analysis a detailed instruction regarding the tissue lubrication test is available at service@hpcosmos.com. Fill the syringe with 10 ml of the lubricant (h/p/cosmos special oil, only). Pump the lubricant under the running belt very slowly and remove the syringe.
  • Page 50: Adjustment Of Running Belt

    After adjustment, observe the running belt at 10 km/h for at least 2 min. Belt must maintain the position. Remove Allen key from screw. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 50 of 99...
  • Page 51: Issues For Qualified Service Personnel

    All maintenance work that is not explained in detail, must not be performed by the operator. Safety inspections, installation and repair work, must also not be performed by the operator. This kind of work must be performed by h/p/cosmos service personnel according to the “h/p/cosmos service instructions”. The “h/p/cosmos service instructions” are available at service@hpcosmos.com.
  • Page 52: Troubleshooting

    In case of any visible or assumed wear and tear (of the device, accessories, labels, etc.), unplug device, exclude reconnection, ❚ mark clearly and inform h/p/cosmos service personnel via telephone and writing. Do not change or remove any labels! Problem...
  • Page 53: Rs232 Troubleshooting

    12.2 RS232 troubleshooting Problem Solution No connection via RS232 For connection to PC with h/p/cosmos software and most external devices use the included RS 232 interface connection cable [cos00097010034]. (wrong cable) No connection via RS232 Check cable and plugs for defects.
  • Page 54: Technical Data

    A-weighted emission sound pressure LpA <70 dB A (50 dB) level at the trainer’s ear (EN 957-6) (Noise emission under load is higher than without load.) © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 54 of 99...
  • Page 55: Essential Performance Characteristics

    When storing for more than 6 months without power connection, the batteries of the MCU may discharge. Please contact service@hpcosmos.com in case of re-installation after storage. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 55 of 99...
  • Page 56: Technical And Legal Requirements

    S (Studio): professional and / commercial use I (inclusive): professional and/or commercial use provided for inclusive use for people with special needs EN 957-6 Accuracy class IEC 62304 Risk class © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 56 of 99...
  • Page 57: Certificates

    Note: In case of special voltage versions, the data on the name plate apply. Connect mains only if data on nameplate and local power supply are identical. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 57 of 99...
  • Page 58: Software, Programs

    Switch off device protection switch ❚ Maintain enough free space to ensure access to cables and the circuit breaker (see “position of subject and operator”). © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 58 of 99...
  • Page 59: Technical Data

    A-weighted emission sound pressure level at the LpA <70 dB A (50 dB) trainer’s ear (EN 957-6) (Noise emission under load is higher than without load.) © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 59 of 99...
  • Page 60: Essential Performance Characteristics

    When storing for more than 6 months without power connection, the batteries of the MCU may discharge. Please contact service@ hpcosmos.com in case of re-installation after storage. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 60 of 99...
  • Page 61: Technical And Legal Requirements

    S (Studio): professional and / commercial use I (inclusive): professional and/or commercial use provided for inclusive use for people with special needs EN 957-6 Accuracy class © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 61 of 99...
  • Page 62: Certificates

    Note: In case of special voltage versions, the data on the name plate apply. Connect mains only if data on nameplate and local power supply are identical. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 62 of 99...
  • Page 63: Software, Programs

    Switch off device protection switch ❚ Maintain enough free space to ensure access to cables and the circuit breaker (see “position of subject and operator”). © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 63 of 99...
  • Page 64: Liability And Warranty

    Limited liabilities apply: If h/p/cosmos or h/p/cosmos organizational bodies, senior management or agents can be held accountable for the payment of damages pertaining to slight negligence (breach of material contractual obligations), the damages shall be limited to damages that could typically have been foreseen. Liability pertaining to slight negligence excludes liability as a result of loss of production, interruption of business and loss of profits.
  • Page 65: Annex I

    17 Annex I 17.1 Installation This device must only be unpacked, transported, installed, commissioned, instructed, maintanined and repaired by h/p/cosmos service personnel (see maintenance). If the packaging has been damaged, please contact service@hpcosmos.com immediately. Make sure no objects, sand, stones, liquids, towels, jewellery, cell phones, containers with liquid etc. can fall into the device or onto the running surface or underneath the running belt.
  • Page 66: Commissioning And Instruction Protocol

    17.2 Commissioning and instruction protocol When installing the device, the h/p/cosmos service personnel instructs the intended operator according to the instructions for use, following this instruction protocol. With the name and signature on the commissioning and instruction protocol, the customer confirm that the installation, commissioning and instruction has been performed correctly and instructed persons fully know how to operate the device safely.
  • Page 67: Commissioning And Instruction Protocol, Signatures

    Furthermore, this will result in loss of liability and warranty. Please fill out the instruction protocol and send it back to h/p/cosmos by fax (+49 18 05 16 76 69), email (sales@hpcosmos.com)
  • Page 68: User Options Op (Details)

     max flashing This value can be reduced to 0.0 km/h for  set unit is flashing advanced users. Adjustable from 0.0 km/h ... 5.0 km/h © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 68 of 99...
  • Page 69 9999 9999 = next sender will be accepted, saved and filtered (can also be set with UP and DOWN) (further settings in user OP23 and administrator OP16 are necessary) © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 69 of 99...
  • Page 70 “accessories / compatible devices”. OFF = RS232 not active / no protocol / interface deactivated h/p/cosmos coscom v1, v2, v3 with baud rate 9600 bps (standard setting COM 1 and COM 2) " [...] [...] " TM treadmill emulation in km/h...
  • Page 71 2 = Display permanently in kJ 3 = Display permanently in Watt After total switch off the default value 0 will be valid again. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 71 of 99...
  • Page 72 OP48 Program step countdown OFF = The time display counts up each program step ON = The time display counts down each program step © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 72 of 99...
  • Page 73: Annex Ii (Pre- & Self-Defined Tests)

    At the end the “index” display shows the UKK fitness index. In case the device receives no or incorrect heart rate signals, an acoustic warning signal occurs. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 73 of 99...
  • Page 74: Graded Test

    Circuit (lap length): 200 m (can be changed) ❚ Increment: 0.5 km/h (can be changed) ❚ STOP must be activated manually by the medical doctor © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 74 of 99...
  • Page 75: Bruce Protocol

    Refer to “test mode” for safety information and adjustment. Step Duration (min) Speed (km/h) Elevation (%) 10.0 12.5 2:00 15.0 17.5 20.0 22.5 25.0 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 75 of 99...
  • Page 76: Cooper Protocol

    ECG stress test Refer to “test mode” for safety information and adjustment. Step Duration (min) Speed (km/h) Elevation (%) 10.0 10.0 10.0 3:00 10.0 15.0 15.0 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 76 of 99...
  • Page 77: Ramp Profile

    02:00 4:00 02:00 6:00 02:00 8:00 02:00 10:00 02:00 12:00 02:00 14:00 02:00 16:00 02:00 18:00 02:00 20:00 30:00 50:00 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 77 of 99...
  • Page 78: Self-Defined Tests

    “+” or “-“. program this step by distance. Confirm with “enter”. Select elevation for step 1 with “+” or “-“. Confirm with “enter”. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 78 of 99...
  • Page 79 Make sure all steps after the last one have a speed of “0 km/h”. Press “start” for at least 5 s to save the program and exit programming. © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 79 of 99...
  • Page 80: Annex Iii (Accessories)

    Title Description Short description The h/p/cosmos para control is designed for remote control of medical devices. But it does not perform medical diagnosis or evaluation. The read out data shall not be the basis for diagnosis or evaluation. For remote control of all h/p/cosmos running machine and ladder-ergometers with MCU2, MCU3, MCU4 and MCU5.
  • Page 81: Arm Support, Optional Stop Button [Cos10107, Cos10108]

    Release button Restart application and interface communication not interrupted Additional safety information Technical data Additional accessories Installation By h/p/cosmos service personnel, only Further information https://www.hpcosmos.com/en/products/individual-products/additional-stop-button-right © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 81 of 99...
  • Page 82: Additional Keyboard For H/P/Cosmos Treadmills [Cos100815, Cos100680]

    Additional keyboard for h/p/cosmos treadmills [cos100815, cos100680] Title Description Short description Additional keyboard (no display!) with magnet holder for remote control of h/p/cosmos treadmill ergometer or h/p/cosmos ladder ergometer. Illustration Application The additional keyboard allows full control over all functions of the MCU like:...
  • Page 83: Emergency Stop Retrofitting [Cos15933, Cos100548, Cos15294]

    Push button Release button Restart application and interface communication not interrupted Additional safety information Technical data Additional accessories Installation By operator Further information https://www.hpcosmos.com/en/products/individual-products/emergency-stop-button- magnet-holder-5-m-spiral-cable © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 83 of 99...
  • Page 84: Special Speed 0 To 10 Km/H / 25 Km/H / 30 Km/H / 40 Km/H / 45 Km/H

    25 km/h cos11995 max. 30 km/h cos10158 max. 40 km/h cos10159 max. 45 km/h Additional accessories Installation By h/p/cosmos service personnel, only Further information © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 84 of 99...
  • Page 85: Heart Rate Measurement Polar Non-Coded [Cos102818]

    POLAR chest belt L cos10902 POLAR transmitter set T31 cos15178 POLAR transmitter set T34 (extended range) Installation By h/p/cosmos service personnel, only Further information © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 85 of 99...
  • Page 86: Heart Rate Measurement Polar W.i.n.d. Coded [Cos100106]

    - Device and chest belt are not connected (see User Option OP 19) Additional accessories cos100420b POLAR WIND transmitter TRX24 cos100420c POLAR WIND WearLink chest belt Installation By h/p/cosmos service personnel, only Further information https://www.hpcosmos.com/en/products/individual-products/polar-heart-rate-receiver-wind © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 86 of 99...
  • Page 87: Heart Rate Measurement Polar H10 [Cos101787-01]

    - Device and chest belt are not connected (see User Option OP 19) Additional accessories cos100420b POLAR WIND transmitter TRX24 cos100420c POLAR WIND WearLink chest belt Installation By h/p/cosmos service personnel, only Further information https://www.hpcosmos.com/de/produkte/zubehoer-optionen/polar-herzfrequenzsensor-h10 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 87 of 99...
  • Page 88: Arm Support, Adjustable [Cos12013]

    Arm support, adjustable [cos12013] Title Description Short description The h/p/cosmos arm supports are a simple solution for unweighting of the subject. Height and width adjustability offers a wide field of application. Illustration Application Adjust the arm support by pulling the locking element and turning the segments.
  • Page 89: Robowalk Expander [Cos30022, Cos30023]

    (for circumference 36 … 51 cm) cos101050-L leg cuff L (for circumference 49 … 75 cm) Installation By h/p/cosmos service personnel, only Further information https://www.hpcosmos.com/en/products/individual-products/robowalk-expander-f-15050 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 89 of 99...
  • Page 90: Optofix [Cos103386]

    12 cm Width: 8.6 cm Height: 14.9 cm Additional accessories cos102065 optogait kit 1m cos102054 optojump kit 1m Installation By operator Further information https://www.hpcosmos.com/en/optofix © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 90 of 99...
  • Page 91: Safety Arch [Cos10079-01]

    Safety arch [cos10079-01] Title Description Short description The h/p/cosmos safety arch prevents the subject from falling. Furthermore, it stops the treadmill in case of falling. Illustration Application 1. Put on the safety harness (h/p/cosmos logo at front). 2. Use the carabine to connect the safety harness with the rope.
  • Page 92: Handrail, Long 2 Pillars 170 / 190 [Cos10166, Cos10167]

    6 cm 6 cm Weight: 18 kg (each) 19 kg (each) Additional accessories Installation By h/p/cosmos service personnel, only Further information https://www.hpcosmos.com/en/products/supplies-options/handrails-both-sides-long-2- pillars-17065 https://www.hpcosmos.com/en/products/supplies-options/handrails-both-sides-long-2- pillars-19065 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 92 of 99...
  • Page 93: Handrail, Adjustable [Cos102010], [Cos102550], [Cos102551]

    69 kg 71 kg material: steel tube, powder coated steel tube, powder coated Installation By h/p/cosmos service personnel, only Further information https://www.hpcosmos.com/en/products/supplies-options/handrails-both-sides- adjustable-17065 https://www.hpcosmos.com/en/products/supplies-options/handrails-both-sides- adjustable-19065 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 93 of 99...
  • Page 94: Handrail, Short (Speed) Left / Right [Cos14763-01, Cos102803]

    132 cm Diameter: 6 cm Height: 98.5 cm Weight: 12 kg (each) Additional accessories Installation By h/p/cosmos service personnel, only Further information https://www.hpcosmos.com/en/products/supplies-options/handrail-left-shortened-speed- xx65 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 94 of 99...
  • Page 95: Reverse Treadmill Belt Rotation [Cos103330], [Cos00098100045-02], [Cos10181-03]

    5 mm thickness; belt guide rollers for running belt centering during reverse operation are added. Installation By h/p/cosmos service personnel, only Further information https://www.hpcosmos.com/en/products/individual-products/reverse-belt-rotation- downhill-15050 https://www.hpcosmos.com/en/products/individual-products/reverse-belt-rotation- downhill-17065 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 95 of 99...
  • Page 96: Crossbar Front Rail [Cos16571-01; Cos15133-03; Cos100947-01; Cos100948-01; Cos100949-01]

    It is not allowed to run with the back to the crossbar. ❚ Technical data Installation By h/p/cosmos service personnel, only Further information https://www.hpcosmos.com/en/products/individual-products/handrail-crossbar-5036- arched-grip-cover © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 96 of 99...
  • Page 97: Footboard Extra Wide 170 / 190 [Cos10228, Cos102289, Cos16586, Cos14764]

    25 kg (each) Additional accessories Separable handrails [cos14233-02] are necessary! Installation By h/p/cosmos service personnel, only Further information https://www.hpcosmos.com/en/products/supplies-options/footboard-right-extra-wide- speed-17065 https://www.hpcosmos.com/en/products/supplies-options/footboard-left-extra-wide- speed-17065 https://www.hpcosmos.com/en/products/supplies-options/footboard-left-extrawide- speed-19065 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 97 of 99...
  • Page 98: Wheelchair Ramp [Cos16186-02], [Cos102931], [Cos14664-03]

    91 cm Height: 13 cm 13 cm Weight: 22 kg 27 kg Additional accessories Installation By operator Further information https://www.hpcosmos.com/en/products/supplies-options/wheelchair-ramp- treadmill-15050 https://www.hpcosmos.com/en/wheelchair-ramp-treadmill-15050-lc https://www.hpcosmos.com/en/products/supplies-options/wheelchair-ramp- treadmill-170-19065 © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 98 of 99...
  • Page 99: Contact

    +49 18 05 16 76 67 (0,14€/min from German landlines, max. 0,42€ from German mobile networks) +49 18 05 16 76 69 email email@hpcosmos.com www.hpcosmos.com © 1988 - 2019 h/p/cosmos sports & medical gmbh cos105000_170-190_65, rev. 1.03 page 99 of 99...