Rs232 Troubleshooting; Error Messages - h/p/cosmos 170-190/65 Series Original Instructions Manual

Hide thumbs Also See for 170-190/65 Series:
Table of Contents

Advertisement

12.2 RS232 troubleshooting

Problem
No connection via RS232
(wrong cable)
No connection via RS232
(cable defect)
No connection via RS232
(wrong COM port)
No connection via RS232
(wrong settings)
No connection via RS232
(blocked COM port)
Acceleration via external device too slow.
Any other problem

12.3 Error messages

Following error messages may be displayed on the UserTerminal:
Error code
E01
E02
E20
E21
E30
E31
E32
E41
E50
E51
E52
© 1988 - 2019 h/p/cosmos sports & medical gmbh
Solution
For connection to PC with h/p/cosmos software and most external devices
use the included RS 232 interface connection cable [cos00097010034].
Check cable and plugs for defects.
Replace defective cable.
Do not use COM 3 on the device
(see "connection of external devices / interfaces").
Choose correct interface protocol on device ("User Options" OP 20 or 21).
Choose correct interface protocol on periphery.
Check installation of peripheral software.
Restart peripheral software.
Restart peripheral device.
Check max. acceleration and deceleration level via RS232
("User Options" OP 29).
unplug device, exclude reconnection, mark clearly and inform h/p/cosmos
service personnel via telephone and writing.
Acoustic code
(x = short beep,
o = long beep)
ooooo xoooo
ooooo xxooo
xxooo ooooo
xxooo xoooo
xxxoo ooooo
xxxoo xoooo
xxxoo xxooo
xxxxo xoooo
xxxxx ooooo
xxxxx xoooo
xxxxx xxooo
Error message
Oil Help
Service Help
Elev Help
Incr Help
Setup Help
Setup Help
Setup Help
Setup Help
FU Help
FU Help
FU Help
cos105000_170-190_65, rev. 1.03
Action
See "lubrication"
See "safety inspection"
Unplug device,
exclude reconnection and
contact
service@hpcosmos.com
page 53 of 99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents