alarmnumber —An alarm number that uniquely identifies the alarm entry.
(Range: 1-65536). Each entry defines a diagnostic sampler at a particular
interval for an object on the device.
variable —The MIB object to monitor. May be fully qualified or relative.
Only variables that resolve to an ASN.1 primitive type of INTEGER are
allowed.
interval —The interval in seconds over which the data is sampled and
compared with the rising and falling thresholds. (Range: 1– 2147483647.
The default is 1 second.)
absolute—Specifies to use a fixed value for the threshold (Default value).
delta—Specifies to use the difference between the current value and the
previous value.
rising-threshold
rising-event-index —Event to trigger when the rising threshold is crossed
(1–65535).
falling-threshold-high
1)
falling-event-index —Event to trigger when the rising threshold is crossed
(1–65535).
startup {rising|falling|rising-falling]
first set to active. If the first sample after this entry is configured is greater than
or equal to the rising threshold and startup rising or startup rising-falling is
configured, a single rising event is generated. If the first sample after this entry
is configured is less than or equal to the falling threshold and startup falling or
startup rising-falling is configured then a single falling event is generated.
string —
owner
Default Configuration
This command has no default configuration.
Command Mode
Global Configuration mode
1544
RMON Commands
value-64 —Rising threshold value (−(2
value-64 —Falling threshold value (−(2
Specify an owner for the alarm (string – no default).
The event that is sent when this entry is
63
63
) to 2
− 1)
63
63
) to 2