Configuring Demand Routing for Primary ISDN Modules
Using Demand Routing for ISDN Connections
8-32
Specifying the busyout-threshold <value> is optional. Include a value to
specify the maximum number of times the ProCurve Secure Router will try
this connect sequence in a single call attempt. If you specify 0, the ProCurve
Secure Router will make an unlimited number of attempts. If you specify any
other number, the ProCurve Secure Router will skip this connect sequence
after it reaches the maximum number. (Depending on your configuration, the
ProCurve Secure Router may cycle through the list of connect sequences more
than once in its attempt to establish a connection. For more information, see
"Configure the Number of Connect Sequence Attempts" on page 8-33.)
There is no default connect sequence. If you do not enter at least one connect-
sequence command, the demand interface will not be able to originate a dial-
up connection.
Deleting a Connect Sequence. To delete a connect sequence entry, enter
the following command from the demand interface configuration mode context:
Syntax: no connect-sequence <sequence-number>

Specify the Order in Which Connect Sequences Are Used

If you enter more than one connect-sequence command, you can configure
the order in which each connect sequence is used. From the demand interface
configuration mode context, enter:
Syntax: connect-order [sequential | last-successful | round-robin]
Table 8-7 lists each option with a brief description.
Table 8-7.
Options for Processing the Connect Sequences
Option
Description
sequential
Process each connect sequence in numerical order, starting with the
lowest number and ending with the highest number.
last-successful
Process the last-successful connect sequence first. If that connect
sequence is not successful, process those remaining in numerical order,
starting with the lowest number and ending with the highest number.
round-robin
First, process the connect sequence that follows the last-successful
connect sequence. If that connect sequence fails, process the next
highest sequence. (If no connection has been made, process the first
connect sequence.)
The default setting is sequential.