H3C S3100 Series Operation Manual page 884

H3c s3100 series ethernet switches operation manual
Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

To do...
Configure the destination
port
Configure the source IP
address
Configure the source port
Configure the number of
probes per test
Configure a test description
Enable history record
Configure the maximum
number of history records
that can be saved
Configure the retaining time
of history record
Configure statistics interval
and the maximum number
of retained statistics
information
Configure the retaining time
of statistics information
Configure test start time
and lifetime
Enable routing table bypass
Configure the TTL
Configure the probe timeout
time
Configure the automatic
test interval
Use the command...
destination-port
port-number
source-ip ip-address
source-port port-number
count times
description string
history-record enable
history-records number
history keep-time keep-time
statistics { interval interval |
max-group number }
statistics keep-time keep-time
test-time begin { hh:mm :ss
[ yyyy/mm/dd ] | now } lifetime
lifetime
sendpacket passroute
ttl number
timeout time
frequency interval
1-15
Remarks
Required in a Tcpprivate test
A Tcppublic test is a TCP connection test on
port 7. Use the hwping-server tcpconnect
ip-address 7 command on the server to
configure the listening service port; otherwise
the test will fail. No port number needs to be
configured on the client; any destination port
number configured on the client will not take
effect.
By default, no destination port number is
configured.
Optional
By default, the source IP address is not
specified.
Optional
By default, no source port is specified.
Optional
By default, one probe is made per time.
Optional
By default, no description information is
configured.
Optional
By default, history record is not enabled.
Optional
By default, the maximum number is 50.
Optional
By default, the retaining time of history record
is 120 minutes.
Optional
By default, statistics interval is 120 minutes
and up to two pieces of statistics information
can be retained.
Optional
By default, the retaining time of statistics
information is 120 minutes.
Optional
By default, no test start time and lifetime is
configured.
Optional
By default, routing table bypass is disabled.
Optional
By default, TTL is 20.
The sendpacket passroute command voids
the ttl command.
Optional
By default, a probe times out in three
seconds.
Optional
By default, the automatic test interval is zero
seconds, indicating no automatic test will be
made.