[DeviceC] cfd service-instance 2 md MD_B ma MA_B
4)
Configure MEPs
# On Device A, configure a MEP list in service instance 1; create and enable inward-facing MEP 1001 in
service instance 1 on Ethernet 1/0/1.
[DeviceA] cfd meplist 1001 4002 5001 service-instance 1
[DeviceA] interface ethernet 1/0/1
[DeviceA-Ethernet1/0/1] cfd mep 1001 service-instance 1 inbound
[DeviceA-Ethernet1/0/1] cfd mep service-instance 1 mep 1001 enable
[DeviceA-Ethernet1/0/1] quit
# On Device B, configure a MEP list in service instances 1 and 2 respectively; create and enable
outward-facing MEP 2001 in service instance 2 on Ethernet 1/0/3.
[DeviceB] cfd meplist 1001 4002 5001 service-instance 1
[DeviceB] cfd meplist 2001 4001 service-instance 2
[DeviceB] interface ethernet 1/0/3
[DeviceB-Ethernet1/0/3] cfd mep 2001 service-instance 2 outbound
[DeviceB-Ethernet1/0/3] cfd mep service-instance 2 mep 2001 enable
[DeviceB-Ethernet1/0/3] quit
# On Device D, configure a MEP list in service instances 1 and 2 respectively, create and enable
outward-facing MEP 4001 in service instance 2 on Ethernet 1/0/1, and then create and enable
inward-facing MEP 4002 in service instance 1 on Ethernet 1/0/3.
[DeviceD] cfd meplist 1001 4002 5001 service-instance 1
[DeviceD] cfd meplist 2001 4001 service-instance 2
[DeviceD] interface ethernet 1/0/1
[DeviceD-Ethernet1/0/1] cfd mep 4001 service-instance 2 outbound
[DeviceD-Ethernet1/0/1] cfd mep service-instance 2 mep 4001 enable
[DeviceD-Ethernet1/0/1] quit
[DeviceD] interface ethernet 1/0/3
[DeviceD-Ethernet1/0/3] cfd mep 4002 service-instance 1 inbound
[DeviceD-Ethernet1/0/3] cfd mep service-instance 1 mep 4002 enable
[DeviceD-Ethernet1/0/3] quit
# On Device E, configure a MEP list in service instance 1; create and enable inward-facing MEP 5001 in
service instance 1 on Ethernet 1/0/4.
[DeviceE] cfd meplist 1001 4002 5001 service-instance 1
[DeviceE] interface ethernet 1/0/4
[DeviceE-Ethernet1/0/4] cfd mep 5001 service-instance 1 inbound
[DeviceE-Ethernet1/0/4] cfd mep service-instance 1 mep 5001 enable
[DeviceE-Ethernet1/0/4] quit
5)
Configure MIPs
# Configure the MIP generation rule in service instance 1 on Device B as explicit.
[DeviceB] cfd mip-rule explicit service-instance 1
# Configure the MIP generation rule in service instance 2 on Device C as default.
[DeviceC] cfd mip-rule default service-instance 2
6)
Configure CC
# On Device A, enable the sending of CCMs for MEP 1001 in service instance 1 on Ethernet 1/0/1.
[DeviceA] interface ethernet 1/0/1
[DeviceA-Ethernet1/0/1] cfd cc service-instance 1 mep 1001 enable
[DeviceA-Ethernet1/0/1] quit