Configuring Cfd Functions; Configuring Cc On Meps; Configuring Lb On Meps - H3C S3100 Series Operation Manual

H3c s3100 series ethernet switches operation manual
Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

Configuring CFD Functions

Configuration Prerequisites
Before configuring CFD functions, you need to complete basic CFD configurations first.

Configuring CC on MEPs

After the CC function is configured, MEPs can send CCMs mutually to check the connectivity between
them.
Follow these steps to configure CC on a MEP:
To do...
Enter system view
Configure the interval field value in
the CCM messages sent by MEPs
Enter Ethernet interface view
Enable CCM sending on a MEP
The relationship between the interval field value in the CCM messages, the interval between CCM
messages and the timeout time of the remote MEP is illustrated in
Table 1-1 Relationship of the interval field value, the interval between CCM messages and the timeout
time of the remote MEP
The interval field value
3
4
5
6
7
On different devices, the MEPs belonging to the same MD and MA should be configured with the
same CCM sending interval.
If the interval field value in the CCM messages sent by MEPs is 3, configuring a large number of
MEPs in the same MD and MA may degrade the device performance.

Configuring LB on MEPs

The LB function can verify the link state between two ends after CC detects a link fault.
Use the command...
system-view
cfd cc interval interval-value
service-instance instance-id
interface interface-type
interface-number
cfd cc service-instance
instance-id mep mep-id enable
The interval between CCM
messages
100 milliseconds
1 second
10 second
60 seconds
600 seconds
1-9
Remarks
Optional
By default, the interval field value is
4.
Required
Disabled by default
Table
1-1.
The timeout time of the remote
MEP
350 milliseconds
3.5 seconds
35 seconds
210 seconds
2100 seconds