H3C S3100 Series Operation Manual page 1037

H3c s3100 series ethernet switches operation manual
Hide thumbs Also See for S3100 Series:
Table of Contents

Advertisement

# Configure Ethernet 1/0/1 to operate in active Ethernet OAM mode (the default) and enable Ethernet
OAM for it.
<DeviceB> system-view
[DeviceB] interface ethernet 1/0/1
[DeviceA-Ethernet1/0/1] oam mode active
[DeviceB-Ethernet1/0/1] oam enable
[DeviceB-Ethernet1/0/1] quit
3)
Verify the configuration
Use the display oam configuration command to display the Ethernet OAM configuration. For
example:
# Display the Ethernet OAM configuration on Device A.
[DeviceA] display oam configuration
Configuration of the link event window/threshold :
--------------------------------------------------------------------------
Errored-symbol Event period(in seconds)
Errored-symbol Event threshold
Errored-frame Event period(in seconds)
Errored-frame Event threshold
Errored-frame-period Event period(in ms)
Errored-frame-period Event threshold
Errored-frame-seconds Event period(in seconds)
Errored-frame-seconds Event threshold
According to the above output information, the detection period of errored frame events is 20 seconds,
the detection threshold is 10 seconds, and all the other parameters use the default values.
You can use the display oam critical-event command to display the statistics of Ethernet OAM critical
link events. For example:
# Display the statistics of Ethernet OAM critical link events on all the ports of Device A.
[DeviceA] display oam critical-event
Port
: Ethernet1/0/1
Link Status : Up
Event statistic :
-------------------------------------------------------------------------
Link Fault
:0
According to the above output information, no critical link event occurred on the link between Device A
and Device B.
You can use the display oam link-event command to display the statistics of Ethernet OAM link error
events. For example:
# Display Ethernet OAM link event statistics of the remote end of Device B.
[DeviceB] display oam link-event remote
Port :Ethernet1/0/1
Link Status :Up
OAMRemoteErrFrameEvent : (ms = milliseconds)
---------------------------------------------------------------------
Event Time Stamp
Errored Frame Threshold
Error Running Total
Dying Gasp
: 0
: 5789
: 1
: 35
:
1
:
1
:
20
:
10
:
1000
:
1
:
60
:
1
Critical Event
Errored FrameWindow
Errored Frame
Event Running Total
1-11
: 0
: 10(100ms)
: 3
: 17

Advertisement

Chapters

Table of Contents
loading